background image

Chapter 6: Advanced Chassis Setup

6-9

6-6 Power 

Supply

The system includes a single 1400 watt power supply, which is auto-switching capa-

ble. Power must be removed from the system when replacing the power supply.

Power Supply Failure

If the power supply module fails, the system will shut down and you will need to 

replace the module. Replacements can be ordered directly from Supermicro (see 

contact information in the Preface).

As there is only one power supply module in the system, power must be com-

pletely removed from the server before removing and replacing the power supply 

for whatever reason.

Removing/Replacing the Power Supply (Figure 6-6)

1.  Power down the server and unplug the AC power cord. 

2.  Push the release tab on the front of the power supply.

3.  Pull the power supply out using the attached handle.

4.  Replace the failed power module with the same model (See Appendix C).

5.  Push the new power supply module into the power bay until you hear a click. 

6.  Reconnect the AC power cord and depress the power button on the control 

panel to restart the system.

Figure 6-7.  Removing/Replacing the Power Supply

1

2

1

4

1

3

Содержание SuperServer 5017GR-TF

Страница 1: ...SUPER SUPERSERVER 5017GR TF USER S MANUAL Revision 1 0...

Страница 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limit...

Страница 3: ...res of the Super X9SRG F motherboard and the SC818G 1K43B chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the system into a rack and check out the server co...

Страница 4: ...erboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC818G 1K43B 1U rackmount server chassis You should follow the procedures given in this chapter when install...

Страница 5: ...v Preface Notes...

Страница 6: ...view 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperatu...

Страница 7: ...4 Chapter 5 Advanced Motherboard Setup 5 1 Handling the Motherboard 5 1 Precautions 5 1 Unpacking 5 1 5 2 Connecting Cables 5 2 Connecting Data Cables 5 2 Connecting Power Cables 5 2 Connecting the C...

Страница 8: ...nstalling the Air Shroud 6 8 Checking the Air Flow 6 8 6 6 Power Supply 6 9 Power Supply Failure 6 9 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utility 7 1 How To Change the Configuration...

Страница 9: ...4 cm counter rotating fans FAN 0117L4 Four 4 cm fans FAN 0102L4 One air shroud MCP 310 81801 0B One passive CPU heatsink SNK P0047PS Riser Cards One RSC R1UG E16R for PCI Express 3 0 x16 card left fro...

Страница 10: ...grated into the chipset to provide a 10 port SATA subsystem which is RAID 0 1 5 and 10 supported Two of these are SATA 3 0 ports and eight are SATA 2 0 ports The SATA drives are hot swappable units No...

Страница 11: ...tton are also included Cooling System The SC818G 1K43B has an innovative cooling design that includes eight 4 cm counter rotating PWM Pulse Width Modulated fans located in the middle section of the ch...

Страница 12: ...ope Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicr...

Страница 13: ...PROCESSOR SSB Socket 1 CPU FRONT PE3 P1 P0 PE2 PE1 DMI DMI PCI Windbond VGA VGA CONN DDR2 RAM TPM Header BMC PHY Super I O HW Monitor NCT7904D W83527 IPMI LAN RJ45 RTL8201F USB 10 11 LPC S SATA0 S SA...

Страница 14: ...1 6 SUPERSERVER 5017GR TF User s Manual Notes...

Страница 15: ...ver It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounde...

Страница 16: ...able before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Rack mounted equipment should...

Страница 17: ...hat the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanica...

Страница 18: ...This rail will fit a rack between 26 and 33 5 deep Identifying the Sections of the Rack Rails The chassis package includes two rack rail assemblies in the rack mounting kit Each assembly consists of t...

Страница 19: ...a server rack Attaching the inner rail extensions to to the inner rails stabilizes the chassis within the rack Installing the Inner Rail Extensions 1 Place the inner rail extensions B over the preatt...

Страница 20: ...ng on to the rack Assembling the Outer Rails 1 Identify the left and right outer rails by examining the ends which bend outward 2 Slide the front section of the outer rail A into the rear section of t...

Страница 21: ...o the proper length so that the outer rail fits snugly within the rack 2 Align the holes on the front of the outer rail with the holes on the front of the rack C and secure with the screws provided 3...

Страница 22: ...ter rails are installed on the rack 2 Line chassis rails with the front of the rack rails 3 Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress...

Страница 23: ...ine how far follow the server will extend out the front of the rack Larger chassis should be positioned to balance the weight between front and back If a bezel is included on your server remove it The...

Страница 24: ...2 10 SUPERSERVER 5017GR TF User s Manual Notes...

Страница 25: ...s others on the drive car riers to keep you constantly informed of the overall status of the system as well as the activity and health of specific components There are also two buttons on the chassis...

Страница 26: ...formation related to different parts of the system This section explains what each LED indicates when illuminated and any corrective action you may need to take Universal Information LED When this LED...

Страница 27: ...hapter 6 for instructions on replacing failed SATA drives Red The red LED to indicate an SATA drive failure If one of the SATA drives fail you should be notified by your system management software Ple...

Страница 28: ...3 4 SUPERSERVER 5017GR TF User s Manual Notes...

Страница 29: ...e operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits another person who is familiar with the power off c...

Страница 30: ...t may be connected to an IT power system In all cases make sure that the unit is also reliably connected to Earth ground Serverboard Battery CAUTION There is a danger of explosion if the onboard batte...

Страница 31: ...PCBs come into contact with your clothing which may retain a charge even if you are wearing a wrist strap Handle a board by its edges only do not touch its components peripheral chips memory modules o...

Страница 32: ...ce is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may r...

Страница 33: ...e hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wri...

Страница 34: ...on page 5 12 for connector locations SATA drive data cables I SATA0 2 SATA sideband cable T SGPIO 1 Control Panel cable JF1 GPU power cables JPW2 PDB connector SATA backplane power cable JPW5 Importa...

Страница 35: ...e various I O ports Figure 5 1 Control Panel Header Pins Figure 5 2 I O Ports NMI x Key Vcc Vcc NIC1 LED Activity NIC2 LED Activity Vcc 3 3V Reset Button Power Button Ground x Key Power On LED HDD LED...

Страница 36: ...ake sure to install the motherboard into the chassis before you install the CPU heatsinks When receiving a motherboard without a processor pre installed make sure that the plastic CPU socket cap is in...

Страница 37: ...ARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are aligned caref...

Страница 38: ...gain and double check that the CPU is aligned properly 7 With the CPU in the socket inspect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load plate Lock the...

Страница 39: ...damage the CPU 5 Add the two remaining screws then finish the installation by fully tightening all four screws Installing a CPU Heatsink Removing the Heatsink 1 Unscrew and remove the heatsink screws...

Страница 40: ...s slot Pay attention to the notch along the bottom of the module to avoid installing incorrectly see Figure 5 4 3 Gently press down on the DIMM module until it snaps into place in the slot Repeat for...

Страница 41: ...G1 3 1 JPR1 1 2 NORMAL 2 3 BIOS RECOVERY 1 2 NORMAL 2 3 ME RECOVERY SLOT3 PCIE 3 0X8 SXB2B SXB2A SXB1A USB JBT1 CMOS CLEAR JSD1 PWRSDOM PWR JF1 ON FAIL RST PS 2 NIC 1 NIC LED UID LED LED PWR HDD X NMI...

Страница 42: ...offering support for two GPU cards the 5017GR TF supports one low profile PCI Express 3 0 x8 expansion card in x16 slot A riser card p n RSC R1U E16R is required to support the expansion card Refer t...

Страница 43: ...B1A USB JBT1 CMOS CLEAR JSD1 PWRSDOM PWR JF1 ON FAIL RST PS 2 NIC 1 NIC LED UID LED LED PWR HDD X NMI DIMMA1 2 3 NMI 1 2 RST DEFAULT JWD WATCH DOG TIMER LAN1 LAN2 UID JI2C2 JI2C3 1 2 Enable 2 3 Disabl...

Страница 44: ...1 10 5 FAN1 FAN4 System CPU Fan Connectors FANA FAND I O Fan Connectors JSD1 SATA Disk On Module DOM Power Connector JSTBY1 Legacy Wake On LAN Header JPW1 24 pin Main ATX Power Connector JPW2 8 pin S...

Страница 45: ...s 1 2 Enabled JPB1 BMC Enable Pins 1 2 Enabled JPME1 Intel ME Mode Select Pins 1 2 Enabled JBR BIOS Recovery Pins 1 2 Off JBT1 CMOS Clear See Section 5 8 Notes Jumpers not indicated are for test purpo...

Страница 46: ...he chassis when viewed from the front These power connectors meet the SSI EPS 12V specification See the tables on the right for pin definitions Power Button The Power Button connection is locat ed on...

Страница 47: ...Blinking NIC Busy Unit ID LED Status State Definition Off UID Off On UID On Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table on the right for pin definitions P...

Страница 48: ...the tables below for pin definitions Back Panel USB 2 0 Pin Definitions Pin Definition Pin Definition 1 5V 5 5V 2 USB_PN1 6 USB_PN0 3 USB_PP1 7 USB_PP0 4 Ground 8 Ground Front Panel USB 2 0 Header Pi...

Страница 49: ...D LED and front panel Unit LED on JF1 if attached to the front Unit ID LED on the chassis will activate Push the Unit ID switch again to turn off both Indicators These Unit ID LED indicators provide e...

Страница 50: ...in Definition 1 5V Standby 2 Ground 3 Wake up System Management Bus A System Management Bus header for the IPMI slot is located at JIPMB1 Connect the appropriate cable here to use the IPMB I2C connect...

Страница 51: ...tform Module TPM which is available from a third party vendor A TPM is a security device that supports encryption and authen tication in hard drives It enables the motherboard to deny access if the TP...

Страница 52: ...2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1...

Страница 53: ...ns 1 2 to reset the system if an ap plication hangs Close Pins 2 3 to generate a non maskable interrupt signal for the application that hangs See the table on the right for jumper settings Watch Dog m...

Страница 54: ...er BIOS Recovery The BIOS Recovery JBR1 is used to enable or disable the BIOS Recovery feature of the motherboard Install the jumper on pins 2 3 to begin the recovery process ME Recovery JPME1 Jumper...

Страница 55: ...1 blinks it means that IPMI is enabled and functioning properly IPMI Heartbeat LED BD1 LED Settings Green Blinking IPMI is ready for use Off IPMI Disabled Unit ID LED The Unit ID LED is used to indica...

Страница 56: ...aged with your system Driver Tool Installation Display Screen Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to the right of these...

Страница 57: ...cial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Note The default User Name and Password for SuperDo...

Страница 58: ...ded from our Web Site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermicro com manuals other SDIII_User_Guide pdf For Linux we will r...

Страница 59: ...damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a gro...

Страница 60: ...ou of system status See Chapter 3 System In terface for details on the LEDs and the control panel buttons Details on JF1 can be found in Chapter 5 Advanced Serverboard Installation 6 3 System Cooling...

Страница 61: ...ver for an extended period of time with the top cover open 2 Turn off the power to the system and unplug the AC power cord 3 Remove the failed fan s wiring from the backplane 4 Remove the four pins se...

Страница 62: ...DVD ROM or floppy drive For a complete listing of peripheral drive options visit the Supermicro web site Hard Drive Installation The hard drives are mounted in drive carriers to simplify their instal...

Страница 63: ...er 6 Advanced Chassis Setup 6 5 Figure 6 3 Removing a Hard Drive Carrier Warning Except for short periods of time swapping hard drives do not operate the server with the hard drive carriers removed 1...

Страница 64: ...rd side facing downward so that the mounting holes align with those in the carrier 4 Secure the hard drive by tightening all six screws Installing a Hard Drive Carrier Into the Chassis 1 Insert the lo...

Страница 65: ...er and data cables from the motherboard and or backplane 3 If you are adding a new drive Remove the dummy tray from the drive bay The mini bezel can be removed by pulling out the hard drive beneath th...

Страница 66: ...e front of the air shroud over the fan tray sliding the front notches C over the pins on the fan tray D Checking the Air Flow Checking the Server s Air Flow 1 Make sure there are no wires or other obj...

Страница 67: ...module in the system power must be com pletely removed from the server before removing and replacing the power supply for whatever reason Removing Replacing the Power Supply Figure 6 6 1 Power down th...

Страница 68: ...6 10 SUPERSERVER 5017GR TF User s Manual Notes...

Страница 69: ...plays all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an ar...

Страница 70: ...not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect special i...

Страница 71: ...e Tab key or the arrow keys to move between fields The date must be entered in Day MM DD YY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M ap...

Страница 72: ...bled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The op tions are Enabled and Disabled AddOn ROM Display Mode This sets the display mode for...

Страница 73: ...e system to instantly power off when the Power Button is pressed The options are 4 Seconds Override and Instant Off Restore on AC Power Loss Use this feature to set the power state after a power outag...

Страница 74: ...codes to overwhelm the processor or damage the system during an attack The default is Enabled Refer to Intel and Microsoft Web Sites for more information Intel AES NI Set to Enabled to use the proces...

Страница 75: ...and heat dissipation Please refer to Intel s web site for detailed information The options are Disabled and Enabled Turbo Mode This feature allows processor cores to run faster than marked frequency i...

Страница 76: ...Acceleration Technology significantly reduces CPU over head by leveraging CPU architectural improvements freeing resources for more other tasks The options are Disabled and Enabled DCA Support This fe...

Страница 77: ...6 Force DDR 1333 Force DDR3 1600 and Force SPD Channel Interleaving This feature selects from the different channel memory interleaving methods The options are Auto 1 Way 2 Way 3 Way and 4 Way Rank In...

Страница 78: ...all USB ports devices The options are Enabled and Dis abled When set to enabled EHCI Controller 1 and 2 below become available EHCI Controller 1 EHCI Controller 2 This feature enables the Enhanced Ho...

Страница 79: ...roller 0 1 This feature is used to activate deactivate the SATA controller and sets the compatibility mode The options are Enhanced and Compatible The default of Serial ATA Controller 0 is Compatible...

Страница 80: ...ser to set the PCI PnP configurations for the following items PCI ROM Priority In case of multiple Option ROMs Legacy and EFI compatible this feature speci fies what ROM to launch The options are Lega...

Страница 81: ...0s SXB1 PCI E 3 0 x16 x8 OPROM SXB2 PCI E 3 0 x16 x8 OPROM CPU1 SLOT 3 PCI E 3 0 x8 OPROM Use this feature to enable or disable PCI E slot Option ROMs The options are Disabled and Enabled Onboard LAN...

Страница 82: ...IRQ 3 IO 3E8h IRQ 5 IO 2E8h IRQ 7 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 Device Mode Use this feature to select the...

Страница 83: ...Redirection Select Enabled to use a COM Port selected by the user for Console Redirection The options are Enabled and Disabled The default setting for COM1 is Disabled and for SOL is Enabled Console...

Страница 84: ...ng with the data bits Select Space to add a Space as a parity bit to be sent with your data bits The options are None Even Odd Mark and Space Stop Bits A stop bit indicates the end of a serial data pa...

Страница 85: ...how the host computer will exchange data with the client computer which is the remote computer used by the user Out of Band Mgmt Port Use this feature to select the port for out of band management Th...

Страница 86: ...setting allows you to configure the ACPI Advanced Configuration and Power Interface sleep state for your system when it is in the Suspend mode The options are Suspend Disabled S1 CPU Stop Clock High P...

Страница 87: ...led Runtime Error Logging Support Change this item to enable or disable runtime error logging The options are En abled and Disabled Memory Correction Error Threshold Change this item to define the sys...

Страница 88: ...tem Boot Event logging to enabled or disabled The options are Disabled and Enabled MECI The Multiple Event Count Increment MECI counter counts the number of times a duplicate event must happen before...

Страница 89: ...Log This feature is used to change the System Event Log SEL configuration SEL Components Change this item to enable or disable all features of System Event Logging The options are Enabled and Disabled...

Страница 90: ...amic Host and Configuration Protocol Dynamic or manually entered by the user Static When Dynamic is selected all the options below are automatically assigned to the sys tem by itself or by an external...

Страница 91: ...ion 2 etc The settings are any detected boot device and Disabled Network Devices This option sets the order of the legacy network devices detected by the motherboard Delete Boot Option This feature al...

Страница 92: ...is defined ONLY this password will need to be entered during each system startup or boot and will also have Administrator rights in the setup Passwords must be at least 3 and up to 20 characters long...

Страница 93: ...iscard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS Setup Utility and reboot...

Страница 94: ...formance Save As User Defaults To set this feature select Save as User Defaults from the Exit menu and press En ter This enables the user to save any changes to the BIOS setup for future use Restore U...

Страница 95: ...ntinue the boot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs BIOS POST Error Codes Beep Code Error Message Description 1 beep Refresh Circ...

Страница 96: ...A 2 SUPERSERVER 5017GR TF User s Manual Notes...

Страница 97: ...kets supporting up to 256 GB of registered ECC DDR3 1600 1333 1066 800 MHz RDIMMs or 64 GB of DDR3 unbuffered non ECC UDIMMs up to 1600 MHz Note See the memory section in Chapter 5 for details GPUs Gr...

Страница 98: ...ting cooling fans fan speed controlled by BIOS setting System Input Requirements AC Input Voltage 180 240 VAC Rated Input Current 7 2A 180V to 9 5 240V Rated Input Frequency 50 60 Hz Power Supply Rate...

Страница 99: ...r agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazard...

Страница 100: ...B 4 SUPERSERVER 5017GR TF Series User s Manual Notes...

Отзывы: