background image

7-4

S

UPER

S

ERVER 5017A-EF User's Manual

7-3   Advanced Setup Confi gurations

Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu 
items:

BOOT Feature

Quiet Boot

This option allows the bootup screen options to be modi

fi

 ed between POST mes-

sages or the OEM logo. Select Disabled to display the POST messages. Select 
Enabled to display the OEM logo instead of the normal POST messages. The op-
tions are 

Enabled

 and Disabled. 

AddOn ROM Display Mode

This sets the display mode for Option ROM. The options are 

Force BIOS

 and 

Keep Current. 

Bootup Num-Lock

This feature selects the Power-on state for Numlock key. The options are Off 
and 

On

.

Interrupt 19 Capture

Interrupt 19 is the software interrupt that handles the boot disk function. When this 
item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 
19 at boot and allow the drives that are attached to these host adaptors to function 
as bootable disks. If this item is set to Disabled, the ROM BIOS of the host adap-
tors will not capture Interrupt 19, and the drives attached to these adaptors will not 
function as bootable devices. The options are 

Enabled

 and Disabled. 

Содержание SUPERSERVER 5017A-EF

Страница 1: ...SUPERSERVER 5017A EF SUPER USER S MANUAL 1 0...

Страница 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Страница 3: ...d the SC504 203B chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 5017A EF into a rack and check out the server configuration prior to poweri...

Страница 4: ...e serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC504 203B server chassis You should follow the procedures given in this chapter when installing remov...

Страница 5: ...Notes Preface v...

Страница 6: ...2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 4 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperatu...

Страница 7: ...ply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cable and AC Adapter 4 18 Chapter 5 Advanced Motherboard Setup 5 1 Handling the Motherboard 5 1...

Страница 8: ...4 System Fans Optional 6 4 6 5 Installing Hard Drives 6 4 Hard Drive Configuration Options 6 6 6 6 Installing an Expansion Card 6 7 6 7 Power Supply 6 9 Replacing the Power Supply 6 9 Chapter 7 BIOS 7...

Страница 9: ...g systems that have been certified for use with the system www supermicro com In addition to the motherboard and chassis various hardware components have been included with the 5017A EF as listed belo...

Страница 10: ...for a complete listing of supported processors www supermicro com Memory The X9SBAA F has one SO DIMM slot that can support up to 8GB of unbuffered ECC DDR3 1333 memory See Chapter 5 for details Seri...

Страница 11: ...emoved from the system and the AC power cord removed when replacing See Chapter 6 for details Hard Drive Subsystem Either two 3 5 internal drive or four 2 5 internal drives with a 2 5 HDD bracket are...

Страница 12: ...ess Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Tec...

Страница 13: ...a suitable location for the rack unit that will hold the SuperServer 5017A EF It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electr...

Страница 14: ...er Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unst...

Страница 15: ...sible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable...

Страница 16: ...ld also refer to the installation instructions that came with the rack unit you are using Installing the Chassis into a Standard Rack 1 Confirm that chassis includes the four mounting screws required...

Страница 17: ...it to be installed into a Telco rack without the use of rails Warning do not pick up the server with the front handles They are de signed to pull the system from a rack only Stability hazard The rack...

Страница 18: ...is should be positioned to balance the weight between front and back 3 If a bezel is included on your chassis remove it Then attach the two front brackets to each side of the chassis then the two rear...

Страница 19: ...specific components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a power on off butto...

Страница 20: ...3 3 Control Panel LEDs The control panel located on the front of the chassis has five LEDs These LEDs provide you with critical information related to different parts of the system This section expla...

Страница 21: ...HDD On the SuperServer 5017A EF this LED indicates SATA drive activity when flashing Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated...

Страница 22: ...SUPERSERVER 5017A EF User s Manual 3 4 Notes...

Страница 23: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 24: ...onsidere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el...

Страница 25: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Страница 26: ...en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher...

Страница 27: ...z installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecor...

Страница 28: ...ft um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the...

Страница 29: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Страница 30: ...nung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o ut...

Страница 31: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Страница 32: ...e or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een be...

Страница 33: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Страница 34: ...ara fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprime...

Страница 35: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Страница 36: ...ctrical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Backp...

Страница 37: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Страница 38: ...eguir todas las leyes y reglamentos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous...

Страница 39: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Страница 40: ...apter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle ande...

Страница 41: ...e code pour tous les autres appareils lectriques que les produits d sign s par Supermicro seulement AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het installeren van h...

Страница 42: ...4 20 SUPERSERVER 5017A EF User s Manual Notes...

Страница 43: ...hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wris...

Страница 44: ...noted should be connected See the layout on page 5 10 for connector locations SATA drive data cables I SATA0 I SATA3 Control Panel cable JF1 Important Make sure the the cables do not come into contact...

Страница 45: ...are color coded in conformance with the PC 99 specification See Figure 5 2 below for the colors and locations of the various I O ports Figure 5 2 Rear I O Ports Rear I O Ports 1 COM Port 3 5 Gb LAN Po...

Страница 46: ...module positioned correctly push until it snaps into place See instructions on the next page Memory Support The X9SBAA F motherboard supports up to 8GB of unbuffered ECC DDR3 1333 memory 5 6 Adding P...

Страница 47: ...e angle 3 Press down until the module locks into place The side clips will automatically secure the SO DIMM module locking it into place 4 To Remove Use your thumbs to gently push the side clips near...

Страница 48: ...5 6 SUPERSERVER 5017A EF User s Manual Figure 5 4 X9SBAA F Layout 5 7 Motherboard Details Notes indicates the location of Pin 1 Jumpers not indicated are for test purposes only...

Страница 49: ...ning Item Connector Description 1 Back Panel I O See Section 5 3 3 JOH1 System Overheat Header 4 SLOT1 33MHz PCI Slot Slot 1 8 JIPMB1 4 pin External BMC I2C Header 9 JBAT1 Internal Backup Battery 10 S...

Страница 50: ...16 of JF1 Refer to the table on the right for pin definitions Power LED Pin Definitions JF1 Pin Definition 15 3 3V 16 Ground HDD LED The HDD LED connection is located on pins 13 and 14 of JF1 Attach a...

Страница 51: ...contacting both pins will power on off the system To turn off the power when set to suspend mode press the button for at least 4 seconds Power Button Pin Definitions JF1 Pin Definition 1 Signal 2 Gro...

Страница 52: ...The Power Supply I2C Connector located at JPI2C1 monitors the status of the power supply fan and system temperature See the table on the right for pin definitions PWR Supply I2C Pin Definitions Pin De...

Страница 53: ...Neg Alarm Speaker Universal Serial Bus USB 0 1 There are two Universal Serial Bus USB 3 0 ports located on the I O backpanel These support data transfer speeds of up to 5Gb sec See the tables on the...

Страница 54: ...eserved 12 I2 C Data 5 Ground 13 H Sync 6 Red Return 14 V Sync 7 Green Return 15 I2 C Clock 8 Blue Return LAN Ports LAN1 LAN2 There are two gigabit LAN ports lo cated on the I O back panel These ports...

Страница 55: ...S Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To clear CMOS 1 First...

Страница 56: ...when plugged into a power source Watch Dog Timer Reset JWD1 The Watch Dog Timer JWD1 is a sys tem monitor that can reboot the system when a software application hangs Close Pins 1 2 to reset the syste...

Страница 57: ...mation 5 10 Onboard Indicators Activity LED Link Speed LED GLAN Activity LED Indicator Color Definition Yellow Flashing ConnectionActive GLAN Link Speed LED Indicator LED Color Definition Off No Conne...

Страница 58: ...the LED location IPMI Heartbeat LED Indicator DM1 LED Settings Green Blinking IPMI is ready for use Rear UID LED UID The rear UID LED is located at UID on the backpanel This LED is used in conjunction...

Страница 59: ...Website at http www supermicro com products Find the product page for your motherboard here where you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert t...

Страница 60: ...perature system voltages and fan status See the figures below for examples of the SuperDoctor III interface Note The default User Name and Password for SuperDoctor III is ADMIN ADMIN Note When SuperDo...

Страница 61: ...User s Manual can be downloaded from the Supermicro web site at http www supermicro com products accessories soft ware SuperDoctorIII cfm For Linux we recommend that you use the SuperDoctor II applica...

Страница 62: ...s practice is not strictly followed Figure 5 9 Installing the Onboard Battery UM A ER A ER O ER Please handle used batteries carefully Do not damage the battery in any way a damaged battery may releas...

Страница 63: ...ery carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded met...

Страница 64: ...dled these wires together to simplify the connection Connect the cable from JF1 on the serverboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connec...

Страница 65: ...he chassis cover in place There are two screws on each side of the chassis and one screw on the back 3 Once the screws have been removed lift the cover upward to remove it from the chassis Caution Exc...

Страница 66: ...he mounting holes in the single fan housing with the holes in the floor of the chassis 6 Secure the single fan housing to the floor of the chassis 7 Connect the fan cables to the motherboard and put t...

Страница 67: ...e 6 6 for supported configuration options 3 Place the hard drive and bracket into the chassis as illustrated in Figure 6 3 If up to four 2 5 hard drives are desired rotate the hard drive brackets nine...

Страница 68: ...ard One 3 5 Hard Drive and one Low Profile Expansion Card Two 2 5 Hard Drives and One Full Height Half Length Expansion Card Hard Drive Configuration Options 2 5 and 3 5 hard drives are supported in t...

Страница 69: ...p on the back of the chassis 2 Remove the screws holding the expansion card clip and the PCI slot cover which covers the PCI slot opening in the back of the chassis 3 Remove the expansion card clip an...

Страница 70: ...riser card 5 Simultaneously insert the PCI slot bracket of the expansion card into the open PCI slot and insert the riser card in to the riser card slot on the motherboard 6 Replace the expansion car...

Страница 71: ...ace Replacing the Power Supply Replacing the Power Supply 1 Power down the system disconnect the power cord and remove the chassis cover 2 Disconnect all wiring from the power supply 3 Remove the four...

Страница 72: ...gn the mounting thru holes on the power supply with the mounting holes in the chassis and reattach the power supply to the chassis using the four screws which were previously set aside 6 Reconnect the...

Страница 73: ...displays all the options that can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an...

Страница 74: ...not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect special i...

Страница 75: ...t The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X9SBAA SMC Version This item displays the version of the BIOS used i...

Страница 76: ...display mode for Option ROM The options are Force BIOS and Keep Current Bootup Num Lock This feature selects the Power on state for Numlock key The options are Off and On Interrupt 19 Capture Interrup...

Страница 77: ...gnate areas in the system memory where an application code can execute and where it cannot thus preventing a worm or a virus from flooding illegal codes to overwhelm the processor or damage the system...

Страница 78: ...Enhanced C3 This feature is used to enable or disable Enhanced C3 State The options are Enabled and Disabled Enhanced C4 Use this feature to enable or disable Enhanced C4 State The options are Enabled...

Страница 79: ...Use this feature to enable or disable MRC Memory Reference Code to loop infinitely The options are Enabled and Disabled ECC Support Use this feature to enable or disable ECC Error Checking and Correc...

Страница 80: ...nk Margin Tool support The options are Disabled and Enabled Dynamic Self Refresh Use this feature to enable or disable the Dynamic Self Refresh in the memory controller The options are Immediate and D...

Страница 81: ...nd width Allowed 25 Bandwidth Allowed 37 5 Bandwidth Allowed 50 Bandwidth Allowed 62 5 Bandwidth Allowed 70 Bandwidth Allowed 87 5 and Bandwidth Allowed 100 P_RTF_THERM Use this feature to set Punit R...

Страница 82: ...e following items Launch Storage OpROM Policy In case of multiple Option ROMs Legacy and EFI compatible this feature specifies what ROM to launch The options are Legacy Only and UEFI Only Launch Video...

Страница 83: ...Enabled The default for LAN 1 is Enabled Default for LAN 2 is Disabled Network Stack Use this feature to enable or disable the network stack PXE and UEFI The op tions are Disabled and Enabled ACPI Co...

Страница 84: ...n Speed Control Mode This feature allows the user to decide how the system controls the speed of the onboard fans Select Full Speed to allow the onboard fans to run at full speed of 100 Pulse Width Mo...

Страница 85: ...address and the Interrupt Request address of Serial Port 1 and Serial Port 2 Select Disabled to prevent the serial port from accessing any system resources When this option is set to Disabled the ser...

Страница 86: ...options for the Console Redirection Settings The most common settings are set as default Terminal Type Select ANSI VT100 VT100 or VT UTF8 Bits per Second BPS 9600 19200 38400 57600 or 115200 Data Bit...

Страница 87: ...ettings The most common settings are set as default Out of Band Mgmt Port COM1 COM2 and SOL Terminal Type Select ANSI VT100 VT100 or VT UTF8 Bits per Second BPS 9600 19200 57600 or 115200 Flow Control...

Страница 88: ...t port This feature cannot currently be changed using the BIOS Wake on LAN Wake on LAN is currently not supported Blink LEDs This feature allows the user to specify the duration for LEDs to blink The...

Страница 89: ...Disabled PCI Error Logging Support Change this item to enable or disable runtime error logging The options are En abled and Disabled Corr Error Threshold Change this item to define the system s memory...

Страница 90: ...er counts the number of oc curences a duplicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines...

Страница 91: ...features of System Event Logging The options are Enabled and Disabled When Enabled the following can be configured Erase SEL This option erases all logged SEL events The options are No Yes On Next re...

Страница 92: ...lly entered below When Dynamic is selected all the options below are automatically assigned to the system by itself or by an external DHCP server The options are Static and DHCP The following items ar...

Страница 93: ...ot Option 1 Boot option 2 etc The settings are Built in EFI Shell any detected boot device and Disabled Network Device BBS Priorities Hard Drive BBS Prioirities This option sets the order of the legac...

Страница 94: ...is defined ONLY this password will need to be entered during each system startup or boot and will also have Administrator rights in the setup Passwords must be at least 3 and up to 20 characters long...

Страница 95: ...option to quit the BIOS Setup without making any permanent changes to the system configuration and reboot the computer Select Yes to Quit Without Saving and and press Enter Save Changes and Reset When...

Страница 96: ...settings designed for maximum system stability but not for maximum performance Save As User Defaults To set this feature select Save as User Defaults from the Exit menu and press En ter This enables t...

Страница 97: ...s Recoverable POST Error Beep Codes When a recoverable type of error occurs during POST BIOS will display a POST code that describes the problem BIOS may also issue one of the following beep codes 1 l...

Страница 98: ...A 2 SUPERSERVER 5017A EF User s Manual Notes...

Страница 99: ...pport up to 8GB of unbuffered ECC DDR3 1333 memory Note see Section 5 6 for details Drive Bays Two 3 5 internal drives or four 2 5 internal drives not hot swappable Serverboard X9SBAA F Mini ITX form...

Страница 100: ...non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 6...

Страница 101: ...B 3 Appendix B System Specifications Notes...

Страница 102: ...form be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such pr...

Отзывы: