background image

Chapter 4: System Safety

4-1

    Chapter 4

System Safety

4-1

Electrical Safety Precautions

!

Basic electrical safety precautions should be followed to protect yourself from

harm and the SuperServer 5013C-M from damage:

   

Be aware of the locations of the power on/off switch on the chassis

as well as the room's emergency power-off switch, disconnection

switch or electrical outlet. If an electrical accident occurs, you can

then quickly remove power from the system.

   

Do not work alone when working with high voltage components.

   

Power should always be disconnected from the system when removing

or installing main system components, such as the motherboard,

memory modules and floppy drive.  When disconnecting power, you should

first power down the system with the operating system first and then unplug

the power cords of all the power supply units in the system.

   

When working around exposed electrical circuits, another person who

is familiar with the power-off controls should be nearby to switch off

the power if necessary.

   

U s e   o n l y   o n e   h a n d   w h e n   w o r k i n g   w i t h   p o w e r e d - o n   e l e c t r i c a l

equipment.  This is to avoid making a complete circuit, which will

cause electrical shock.  Use extreme caution when using metal tools,

which can easily damage any electrical components or circuit boards

they come into contact with.

   

Do not use mats designed to decrease static electrical discharge as

protection from electrical shock.  Instead, use rubber mats that have

been specifically designed as electrical insulators.

   

The power supply power cords must include a grounding plug and must

be plugged into grounded electrical outlets.

Содержание SuperServer 5013C-M

Страница 1: ...SUPER SUPERSERVER 5013C M USER S MANUAL Revision 1 0a...

Страница 2: ...R INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED W...

Страница 3: ...tion The first chapter provides a checklist of the main components included with the server system and describes the main features of the Super P4SCi motherboard and the SC512C chassis Chapter 2 Serve...

Страница 4: ...or removing processors or main memory and when reconfiguring the motherboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC512C 1U rackmount server chassis You...

Страница 5: ...v Preface Notes...

Страница 6: ...Precautions 2 2 Rack Mounting Considerations 2 3 2 4 Installing the SuperServer 5013C M into a Rack 2 4 Identifying the Sections of the Rack Rails 2 4 Installing the Chassis Rails 2 5 Installing the...

Страница 7: ...Ports 5 4 5 5 Installing Processors 5 5 5 6 Installing Memory 5 7 5 7 Adding PCI Cards 5 8 5 8 Motherboard Details 5 9 P4SCi Layout 5 9 P4SCi Quick Reference 5 10 5 9 Connector Definitions 5 11 Power...

Страница 8: ...5 21 IDE Connectors 5 21 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 6 2 Control Panel 6 2 6 3 System Fans 6 3 System Fan Failure 6 3 6 4 Drive Bay Installation Removal 6 4 Acce...

Страница 9: ...Options 7 12 7 5 Security 7 13 7 6 Boot 7 14 7 7 Exit 7 15 Appendices Appendix A BIOS POST Messages A 1 Appendix B BIOS POST Codes B 1 Appendix C Installing Software and Drivers C 1 Introduction to S...

Страница 10: ...x Notes SUPERSERVER 5013C M User s Manual...

Страница 11: ...our web site for information on operating systems that have been certified for use with the 5013C M www supermicro com and for regular updates on supported processor speeds In addition to the motherbo...

Страница 12: ...DDR memory providing bandwidth of up to 6 4 GB s using DDR400 SDRAM The MCH supports configu rations of a 800 MHz FSB with a 400 333 memory interface a 533 MHz FSB with a 333 266 memory interface and...

Страница 13: ...256 MB 512 MB and 1 GB may be used to populate the DIMM slots Serial ATA A Serial ATA controller is incorporated into the E7210 chipset to provide a two port Serial ATA subsystem The Serial ATA drive...

Страница 14: ...scue Figure 1 1 Intel E7210 Chipset System Block Diagram Note This is a general block diagram Please see Chapter 5 for details MCH Processor 0 ICH 6300ESB USB Ports 4 ATA 100 Ports 2 DIMM DIMM Dual Ch...

Страница 15: ...ation LEDs indicate power on network activity hard disk drive activ ity overheat warning and drive failure The control panel also includes a main power button and a system reset button Rear I O Panel...

Страница 16: ...1 6 SUPERSERVER 5013C M User s Manual Figure 1 2 Rear I O Panel Parallel Port USB Ports VGA Port Keyboard Mouse Ports COM1 Port Ethernet Ports...

Страница 17: ...ress SuperMicro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Tec...

Страница 18: ...1 8 SUPERSERVER 5013C M User s Manual Notes...

Страница 19: ...was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the SuperServer...

Страница 20: ...be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may cause the rac...

Страница 21: ...omised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the...

Страница 22: ...ections of the Rack Rails You should have received two rack rail assemblies with the SuperServer 5013C M Each of these assemblies consist of two sections an inner fixed chassis rail that secures to th...

Страница 23: ...a locking tab which serves two functions The first is to lock the server into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server...

Страница 24: ...ils Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting See Figure 2 3 When the server has been pushed completel...

Страница 25: ...you are installing the SuperServer 5013C M into a Telco type rack follow the directions given on the previous pages for rack installation The only difference in the installation procedure will be the...

Страница 26: ...erver 2 Check the CPU processor You may have one processor already installed into the system board The processor should have its own heatsink attached See Chapter 5 for instruc tions on processor inst...

Страница 27: ...Chapter 2 Server Installation 2 9 Figure 2 5 Accessing the Inside of the SuperServer 5013C M SUPER R P 4S CI...

Страница 28: ...disk drive to the system 3 Check the IDE disk drives Depending upon your system s configuration your system may have an IDE hard drive already installed If you need to install an IDE hard drive please...

Страница 29: ...This chapter explains the meanings of all LED indi cators and the appropriate response you may need to take 3 2 Control Panel Buttons There are two push button buttons located on the front of the cha...

Страница 30: ...obstructing the airflow in the system or the ambient room temperature being too warm You should also check to make sure that the chassis cover is installed and that all fans are present and operat ing...

Страница 31: ...Chapter 3 System Interface 3 3 Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated when the system is operating...

Страница 32: ...3 4 SUPERSERVER 5013C M User s Manual Notes...

Страница 33: ...er you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits an...

Страница 34: ...into a cooling fan Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit bo...

Страница 35: ...ll components and printed circuit boards PCBs in their antistatic bags until ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs...

Страница 36: ...that the chassis cover is in place when the 5013C M is operating to assure proper cooling Out of warranty damage to the 5013C M system can occur if this practice is not strictly followed Figure 4 1 In...

Страница 37: ...handle them very carefully see previous chapter To prevent the P4SCi motherboard from bend ing keep one hand under the center of the board to support it when handling The following measures are gener...

Страница 38: ...ntil the rails lock into place 2 Check compatibility of motherboard ports and I O shield The P4SCi requires a chassis big enough to support a 12 x 9 5 motherboard such as Supermicro s SC512C 1U rackmo...

Страница 39: ...ted See the layout on page 5 10 for connector locations IDE Device Cables J2 and J5 Floppy Drive Cable J7 Control Panel Cable JF1 Connecting Power Cables The P4SCi has a 24 pin primary power supply co...

Страница 40: ...rol Panel Header Pins Note The COM2 port is a header on the motherboard located behind the mouse and keyboard ports Mouse Green Parallel Port Burgundy GLAN1 GLAN2 Keyboard Purple COM1 Port Turquoise V...

Страница 41: ...to 2 40 GHz 1 Lift the lever on the CPU socket 2 Install the CPU in the socket Make sure that Pin 1 of the CPU is seated on Pin 1 of the socket both corners are marked with a triangle 3 Press the lev...

Страница 42: ...5 6 SUPERSERVER 5013C M User s Manual Figure 5 3 478 pin Socket Empty and with Processor Installed Figure 5 4 Heatsink SNK P0002 Installation...

Страница 43: ...he DIMM module until it snaps into place in the slot see Figure 5 5 CAUTION Exercise extreme care when installing or remov ing DIMM modules to prevent any possible damage To Install Insert module vert...

Страница 44: ...ate Fully seat the PCI card into the riser card and screw it into the metal retention rail Then insert the riser card into the PCI slot on the motherboard pushing down with your thumbs evenly on both...

Страница 45: ...eyboard Mouse JBT1 82541 J17 CHS FAN1 CPU FAN J P 1 J P 2 JP20 J11 USB1 2 COM1 Parallel Port J8 VGA ATX Power Connector J20 CPU 478 mPGA GLAN1 GLAN2 DIMM0A DIMM0B J21 12V PWR MCH JF1 PCI X 1 PCI X 2 P...

Страница 46: ...ed JPUSB USB1 2 Wake Up Pins 1 2 Disabled JPWAKE Keyboard Wakeup Pins 1 2 Disabled Connectors Description DIMM 0A 0B 1A 1B Memory Slots 1 through 4 Fans CPU Fan Chassis Fans 1 4 Overheat Fan GLAN1 2 G...

Страница 47: ...1 Required Connection IR Connector The infrared connector is located on J16 See the table on the right for pin definitions See the Tech nical Support section of our web page for information on the inf...

Страница 48: ...conds See the table on the right for pin defini tions Pin Number 1 2 Definition Signal 3V Stby PW_ON Pin Definitions JF1 Pin Number 3 4 Definition Reset Ground Reset Pin Definitions JF1 Overheat LED O...

Страница 49: ...i nitions Hard Drive Activity LED Pin Definitions JF1 Pin Number 13 14 Definition 5V HD Activity Pin Number 15 16 Definition 5V Ground PWR_LED Pin Definitions JF1 Serial Port Pin Definitions COM1 COM2...

Страница 50: ...See the table on the right for pin definitions Universal Serial Bus USB There are two Universal Serial Bus ports located on the I O panel and two additional USB headers located on the motherboard The...

Страница 51: ...use this feature Wake On Ring The Wake On Ring header is desig nated WOR This function allows your computer to receive and be awak ened by an incoming call when in the suspend state See the table on...

Страница 52: ...n a two pin jumper Closed means the jumper is on both pins and Open means the jumper is either on only one pin or completely removed Connector Pins Jumper Cap Setting Pin 1 2 short 3 2 1 3 2 1 CMOS Cl...

Страница 53: ...r Jumper The speaker jumper is located on J18 and allows you to choose be tween using the internal or exter nal speakers For the internal speaker jump pins 3 and 4 To use an external speaker place the...

Страница 54: ...ble the Keylock function and leave the jumper open off to disable it The default setting is open See the table on the right for jumper settings Jumper Position Closed Open Definition Enabled Disabled...

Страница 55: ...of jumper JPL2 to enable or disable the Gigabit LAN2 port on the motherboard See the table on the right for jumper settings The default setting is enabled LAN1 is enabled disabled via BIOS Jumper Posi...

Страница 56: ...s two connectors to support two drives This special cable should be used to take advantage of the speed this new technology offers The blue connector connects to the onboard IDE connector inter face a...

Страница 57: ...s There are no jumpers to config ure the onboard IDE interfaces J2 and J5 See the table on the right for pin definitions You must use the ATA100 66 cable included with your system to benefit from the...

Страница 58: ...5 22 SUPERSERVER 5013C M User s Manual Notes...

Страница 59: ...arefully The following measures are generally suffi cient to protect your equipment from ESD discharge Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded meta...

Страница 60: ...h system control buttons and status indicators These wires have been bundled together in a ribbon cable to simplify the connection Connect the cable from JF1 on the motherboard to JP4 on the Control P...

Страница 61: ...air seal is properly installed and making a good seal in order for the cooling air to circulate properly through the chassis System Fan Failure The blower fan runs at a full 100 rpm If this fan fails...

Страница 62: ...ve is not hot swappable meaning system power must be turned off before installing or removing To install or remove the drive first power down the system and then remove the top cover of the chassis Un...

Страница 63: ...wo buttons on the top of the chassis to release the top cover and at the same time push the cover away from you until it stops You can then lift the top cover from the chassis to gain full access to t...

Страница 64: ...will hear a click Next depress the two buttons on the top of the chassis to release the top cover and push it away from you You can then lift the top cover from the chassis to gain full access to the...

Страница 65: ...puter is turned off a back up battery provides power to the BIOS Flash chip enabling it to retain the system parameters Each time the computer is powered on the computer is then con figured with the v...

Страница 66: ...be activated in one of two ways 1 By pressing Del immediately after turning the system on or 2 When the following message appears briefly at the bottom of the screen during the POST Power On Self Test...

Страница 67: ...s are None 360Kb 5 25 in 1 2MB 5 25 in 720Kb 3 5 in 1 44 MB 3 5 in and 2 88MB 3 5 in Legacy Diskette B This setting allows the user to set the type of floppy disk drive installed as diskette B The opt...

Страница 68: ...BIOS Setup Choose Advanced BIOS Setup from the Award BIOS main menu with the Left Right arrow keys You should see the following display Select one of the items in the left frame of the screen to go t...

Страница 69: ...the option allows the user to determine the ACPI Suspend type The options are S1 POS S3 STR and S1 S3 APIC Mode This setting allows you to Enable or Disable APIC APIC is used to assign interrupt sign...

Страница 70: ...ically configure the settings for SATA controller Select Combined Mode to combine both Parallel ATA PATA and Serial ATA SATA functions with a maximum of two IDE drives available for each channel If En...

Страница 71: ...and reduce the heat generated by the CPU The options for this setting are 87 5 75 62 5 50 37 5 25 and 12 5 7 4 3 I O Device Configuration Keyboard Input Clock This setting allows to you set the speed...

Страница 72: ...pins The options are RxD2 TxD2 and IR Rx2Tx2 Onboard Parallel Port This setting allows the user to set the address and the corresponding IRQ for the onboard parallel port The options are Disabled 378...

Страница 73: ...configuration has caused such a serious conflict that the OS cannot reboot the system The options are Enabled and Disabled PnP OS Install Power On Function This setting allows the user to decide which...

Страница 74: ...d Manual 7 4 5 Console Redirection Console Redirection Select Enabled to redirect the console via the COM port Select Disabled to redirect the Console when the keyboard is absent The options are Enabl...

Страница 75: ...set the CPU warning temperature If the CPU temperature reaches this threshold an alarm will activate and a warning message will be displayed onscreen The options are Disabled 600 C 1400 F 650 C 1490...

Страница 76: ...available for retail CPUs Spread Spectrum Spread Spectrum is a technique used to stablize a system by reducing the level of ElectroMagnetic Interference The options are Enabled and Disabled CPU Clock...

Страница 77: ...s highlighted on the above screen press the Enter key When prompted type the User Password in the dialogue box to set or to change the User Password Password Check 7 5 Security Choose Security from th...

Страница 78: ...ter 2 Pri Slave 3 Sec Master 4 Sec Slave 5 USBHDD0 6 USBHDD1 7 USBHDD2 and Bootable Add In cards X X X X XRemovable Device Priority This setting allows you to set the priority of removable devices The...

Страница 79: ...Setup routine without saving any changes you may have made Your sys tem should then continue with the boot up procedure Third Boot Device This item allows the user to set the Third boot up device The...

Страница 80: ...e Load Optimized Defaults Highlight this item and hit Enter to load the optimized settings for all items in the BIOS Setup These settings provide you with optimal system performance Discard Changes Wh...

Страница 81: ...he Power On Self Test POST the BIOS will check for problems If a problem is found the BIOS will activate an alarm or display a message The following is a list of such BIOS messages 1 long beep Memory...

Страница 82: ...A 2 SUPERSERVER 5013C M User s Manual Notes...

Страница 83: ...he Xgroup codes locating in physical address 1000 0 02h Reserved 03h Initial Superio_Early_Init switch 04h Reserved 05h 1 Blank out screen 2 Clear CMOS error flag 06h Reserved 07h 1 Clear 8042 interfa...

Страница 84: ...al EARLY_PM_INIT switch 1Eh Reserved 1Fh Load keyboard matrix notebook platform 20h Reserved 21h HPM initialization notebook platform 22h Reserved 23h 1 Check validity of RTC value e g a value of 5Ah...

Страница 85: ...eserved 47h Initialize EISA slot 48h Reserved 49h 1 Calculate total memory by testing the last double word of each 64K page 2 Program writes allocation for AMD K5 CPU 4Ah Reserved 4Bh Reserved 4Ch Res...

Страница 86: ...isters according to items described in Setup Auto configuration table 6Ch Reserved 6Dh 1 Assign resources to all ISA PnP devices 2 Auto assign ports to onboard COM ports if the corresponding item in S...

Страница 87: ...n IRQs to PCI devices 7 Initialize APM 8 Clear noise of IRQs 86h Reserved 87h Reserved 88h Reserved 89h Reserved 90h Reserved 91h Reserved 92h Reserved 93h Read HDD boot sector information for Trend A...

Страница 88: ...B 6 SUPERSERVER 5013C M User s Manual Notes...

Страница 89: ...PATA In addition PATA cables can only extend to 40cm while SATA cables can extend up to one meter Overall SATA provides better functionality than PATA Intel 6300ESB I O Controller Hub Located in the S...

Страница 90: ...stems that support Enhanced Mode such as WindowsXP Windows2000 and Windows2003 you can set SATA and PATA to the Enhanced Mode These newer operating systems can accommodate both En hanced and Combined...

Страница 91: ...you need to install a third party SCSI or RAID driver displays h When the Windows OS Setup screen appears press S to specify additional device s i Insert the driver diskette named Adaptec Embedded Ser...

Страница 92: ...em on the list You should install everything here except for the SUPER Doctor utility which is optional The bottom icon with a CD on it allows you to view the entire contents of the CD C 3 Other Softw...

Страница 93: ...e Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system Supero Doctor III displays crucial system informat...

Страница 94: ...C 6 SUPERSERVER 5013C M User s Manual Notes...

Страница 95: ...profile SDRAM dual channel memory DIMM Sizes 128 MB 256 MB 512 MB 1 GB 184 pin modules supported Operating Systems Supported Windows NT Windows 2000 Solaris Netware SCO UNIX and Linux Serial ATA Contr...

Страница 96: ...ing 1400 BTUs hr for rated output power of 260W Operating Environment Operating Temperature 10 to 35 degrees C Non operating Temperature 35 to 60 degrees C Operating Relative Humidity 5 90 non condens...

Отзывы: