Chapter 2: Server Installation
2-5
Installing the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of
the chassis making sure the five screw holes line up.
Note that these two
rails are left/right specific. Screw the rail securely to the side of the
chassis (see Figure 2-2). Repeat this procedure for the other rail on the
other side of the chassis. You will also need to attach the rail brackets
when installing into a telco rack.
Locking Tabs:
As you have seen, both chassis rails have a locking tab,
which serves two functions. The first is to lock the server into place
when installed and pushed fully into the rack, which is its normal position.
Secondly, these tabs also lock the server in place when fully extended
from the rack. This prevents the server from coming completely out of
the rack when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails
Installing the Rack Rails
Determine where you want to place the SuperServer 5013C-T/5013C-i in
the rack (see Rack and Server Precautions in Section 2-3). Position the
fixed rack rail/sliding rail guide assemblies at the desired location in the
rack, keeping the sliding rail guide facing the inside of the rack. Screw the
assembly securely to the rack using the brackets provided. Attach the
Содержание SuperServer 5013C-i
Страница 1: ...SUPER SUPERSERVER 5013C T SUPERSERVER 5013C i USER S MANUAL Revision 1 1b...
Страница 5: ...v Preface Notes...
Страница 10: ...x Notes SUPERSERVER 5013C T 5013C i User s Manual...
Страница 18: ...1 8 SUPERSERVER 5013C T 5013C i User s Manual Notes...
Страница 32: ...3 4 SUPERSERVER 5013C T 5013C i User s Manual Notes...
Страница 82: ...7 18 SUPERSERVER 5013C T 5013C i User s Manual Notes...
Страница 84: ...A 2 SUPERSERVER 5013C T 5013C i User s Manual Notes...
Страница 90: ...B 6 APPENDIX A SUPERSERVER 5013C T 5013C i User s Manual Notes...
Страница 118: ...D 4 SUPERSERVER 5013C T 5013C i Manual Notes...