2-4
SUPERSERVER 4048B-TRFT USER'S MANUAL
2-5 Rack Mounting Instructions
This section provides information on installing the chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean
that the assembly procedure will differ slightly from the instructions provided. You
should also refer to the installation instructions that came with the rack unit you are
using. Note: This rail will
fi
t a rack between 26.5" and 36.4" deep
Identifying the Sections of the Rack Rails
The chassis package includes a rack rail assembly in the rack mounting kit. Each
assembly consists of three sections: An inner chassis rail which secures directly to
the chassis, an outer rail that secures to the rack, and a middle rail which extends
from the outer rail. These assemblies are speci
fi
cally designed for the left and right
side of the chassis..
Installing the Inner Rails on the Chassis
Installing the Inner Rails
1. Place the inner rails on the side of the chassis aligning the hooks of the chas-
sis with the inner rail holes. Make sure that the rail faces "outward" so that it
will
fi
t with the rack's mounting bracket.
2. Slide the rail toward the front of the chassis.
Figure 2-1. Identifying the Different Rail Sections
Inner Rail
Rail Assembly
(Shown with Rails
Retracted)
This Side Faces
Outward
Locking Tab
Middle Rail
Outer Rail
Содержание SuperServer 4048B-TRFT
Страница 1: ...SUPER USER S MANUAL Revision 1 0a SuperServer 4048B TRFT...
Страница 5: ...v SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Страница 24: ...2 10 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Страница 48: ...4 20 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Страница 80: ...5 32 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Страница 90: ...6 10 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Страница 142: ...7 52 SUPERSERVER 4048B TRFT USER S MANUAL Notes...
Страница 144: ...A 2 SUPERSERVER 4048B TRFT USER S MANUAL Notes...