Chapter 2: Server Installation
2-3
•
Allow any hot plug drives and power supply modules to cool before touching
them.
•
Always keep the rack's front door and all panels and components on the servers
closed when not servicing to maintain proper cooling.
Rack Mounting Considerations
Ambient Operating Temperature
If installed in a closed or multi-unit rack assembly, the ambient operating tempera-
ture of the rack environment may be greater than the ambient temperature of the
room. Therefore, consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum rated ambient tempera-
ture (Tmra).
Reduced Airflow
Equipment should be mounted into a rack so that the amount of airflow required
for safe operation is not compromised.
Mechanical Loading
Equipment should be mounted into a rack so that a hazardous condition does not
arise due to uneven mechanical loading.
Circuit Overloading
Consideration should be given to the connection of the equipment to the power
supply circuitry and the effect that any possible overloading of circuits might have
on overcurrent protection and power supply wiring. Appropriate consideration of
equipment nameplate ratings should be used when addressing this concern.
Reliable Ground
A reliable ground must be maintained at all times. To ensure this, the rack itself
should be grounded. Particular attention should be given to power supply connec-
tions other than the direct connections to the branch circuit (i.e. the use of power
strips, etc.).
Warning!
To prevent bodily injury when mounting or servicing this unit in a
rack, you must take special precautions to ensure that the system remains
stable. The following guidelines are provided to ensure your safety:
•
This unit should be mounted at the bottom of the rack if it is the only unit in
the rack.
•
When mounting this unit in a partially filled rack, load the rack from the bottom
to the top with the heaviest component at the bottom of the rack.
•
If the rack is provided with stabilizing devices, install the stabilizers before
mounting or servicing the unit in the rack.
Содержание 2022TC-BIBQRF
Страница 1: ...A SERVER 2022TC BIBQRF 2022TC BTRF SUPER USER S MANUAL Revision 1 0d ...
Страница 26: ...2 12 A SERVER 2022TC BIBQRF BTRF USER S MANUAL Notes ...
Страница 30: ...A SERVER 2022TC BIBQRF BTRF USER S MANUAL 3 4 Notes ...
Страница 50: ...4 20 A SERVER 2022TC BIBQRF BTRF USER S MANUAL Notes ...
Страница 97: ...Chapter 6 Advanced Chassis Setup 6 19 Notes ...
Страница 115: ...7 18 A SERVER 2022TC BIBQRF BTRF USER S MANUAL Notes ...
Страница 117: ...A 2 A SERVER 2022TC BIBQRF BTRF USER S MANUAL Notes ...
Страница 120: ...B 1 Appendix B System Specifications Notes ...