background image

USER’S MANUAL 

Revision 1.0c

SuperServer

®

6019P-WT8

Содержание SuperServer 6019P-WT8

Страница 1: ...USER S MANUAL Revision 1 0c SuperServer 6019P WT8...

Страница 2: ...commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s instruction manual may cause harmful in...

Страница 3: ...rivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utilities https www supermicro com wftp driver Product saf...

Страница 4: ...ns 16 Server Precautions 17 Rack Mounting Considerations 17 Ambient Operating Temperature 17 Airflow 17 Mechanical Loading 17 Circuit Overloading 18 Reliable Ground 18 2 3 Installing the Rails 19 Iden...

Страница 5: ...Installation 33 Motherboard Battery 34 3 4 Chassis Components 35 Hard Drives 35 System Cooling 37 Installing Fans 37 Power Supply 39 Chapter 4 Motherboard Connections 4 1 Power Connections 40 4 2 Head...

Страница 6: ...ace 6 5 IPMI 93 6 6 Security 96 6 7 Boot 100 6 8 Save Exit 102 Appendix A BIOS Codes Appendix B Standardized Warning Statements for AC Systems Appendix C System Specifications Appendix D UEFI BIOS Rec...

Страница 7: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 8: ...claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the server It should be situated in a clean dust free area that is well ventilated Avoid areas wh...

Страница 9: ...et Type Socket P Memory Supports up to 3TB of registered ECC DDR4 2933 RDIMM Registered DIMM or LRDIMM Load Reduced DIMM memory supports up to four Intel Optane DCPMMs Chipset Intel C621 chipset Expan...

Страница 10: ...on Used to reboot the system 3 Unit Identifier LED Used to locate the server when in large racks and server banks 4 NIC LED Indicates network activity when flashing 5 HDD LED Indicates SAS SATA drive...

Страница 11: ...stration below for the features included on the front of the chassis Rear Chassis Features Item Feature Description 1 Power Supply Single 600 650W power supply module 2 Rear I O ports Rear I O ports s...

Страница 12: ...U2_PORT2A CPU2_PORT2B CPU2_PORT2C CPU2_PORT2D CPU1_PORT3C CPU1_PORT3D CPU1_PORT3C CPU1_PORT3D CPU1_PORT3B CPU1_PORT3A CPU1_PORT3B CPU1_PORT3A SXB1B CPU1 PCI E 3 0 X16 CPU2 PCI E 3 0 X16 CPU2_PORT3 SXB...

Страница 13: ...2 C header for an IPMI card JL1 Chassis intrusion header JM2_1 M 2 slot supported by PCH JNVI2 C1 JNVI2 C2 NVMe I2 C headers JPI2 C1 Power Supply SMBbus I2 C header JPWR1 JPWR2 12V 8 pin power supply...

Страница 14: ...l Purpose I O port USB0 1 Back panel USB 3 0 ports USB2 3 Back panel USB 3 0 ports USB4 5 USB 3 0 headers VGA Back panel VGA port LED Description Status LE1 UID Unit Identifier LED Solid Blue Unit Ide...

Страница 15: ...SB BIOS SPI AST2500 BMC 5 RMII NCSI VGA CONN BMC Boot Flash DDR4 5 1 PHASE 2133 2666 2133 2666 DDRIV P1 P1 P0 VR13 P0 G 0 DDRIV D 0 C 0 B 0 A 0 UPI PCI E X4 X4 G3 DMI3 2 x NVME E 0 F 0 SNB CORE DDR IV...

Страница 16: ...Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where...

Страница 17: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...

Страница 18: ...ention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit...

Страница 19: ...square pegs to fit into your rack holes If you have an older rack with round holes these brackets must be removed and you must use screws to secure the rail to the rack Outer Rail Installation 1 Align...

Страница 20: ...icing Failure to stabilize the rack can cause the rack to tip over Figure 2 1 Installing the Outer Rails Installing the Chassis into the Rack Installing the Chassis into the Rack 1 Align the chassis w...

Страница 21: ...erating system to power down the system 2 After the system has completely shut down disconnect the AC power cord s from the power strip or outlet If your system has more than one power supply remove t...

Страница 22: ...n 3 1 before installing the processors When handling the processor package avoid placing direct pressure on the label area of the CPU or socket The processor and heatsink should be assembled together...

Страница 23: ...the CPU Socket Remove the dust cover from the CPU socket to expose the socket and socket pins as shown in the illustration below Note Do not touch the socket pins to avoid damage to them and to preven...

Страница 24: ...otch B of the processor clip and sliding notch C of the CPU into notch C of the processor clip 4 Examine all corners of the CPU to ensure that it is properly seated on the processor clip Once the CPU...

Страница 25: ...al grease side facing up locate the hollow triangle located at the corner of the processor carrier assembly a in the graphic Note a larger hole and plastic mounting clicks located next to the hollow t...

Страница 26: ...dule PHM Removing the Processor Heatsink Module PHM Before removing the processor heatsink module PHM unplug power cord from the power outlet 1 Using a T30 Torx bit screwdriver turn the screws on the...

Страница 27: ...et CPU Socket Removing the Processor Heatsink Module from the Motherboard Before removing the processor heatsink module PHM power down as described in Section 3 1 1 Using a T30 Torx bit screwdriver tu...

Страница 28: ...Note that 2933 MHz memory is supported by the 82xx 62xx 52xx platform only Only Platinum level and Gold level processors support Intel OptaneTM DC Persistent Memory Module DCPMM Notes 1 When installi...

Страница 29: ...opulation sockets are normally symmetric with exceptions for 1 DCPMM per socket and 1 DCPMM per node case Currently DCPMM modules operate at 2666 MHz No mixing of DCPMM and NVMDIMMs within the same pl...

Страница 30: ...666 8RX4 N A 4H 128GB 2666 2666 LRDIMM QRx4 32 GB 64 GB 2666 2666 LRDIMM 3Ds QRX4 N A 2H 64GB 2666 2666 8Rx4 N A 4H 128 GB 2666 2666 DDR4 Memory Support for the Intel Xeon Scalable Processor Type Rank...

Страница 31: ...33 2666 RDIMM 3Ds QRX4 N A 2H 64GB 2933 2666 RDIMM 3Ds 8RX4 N A 4H 128GB 2933 2666 LRDIMM QRx4 32GB 64GB 2933 2666 LRDIMM 3Ds QRX4 N A 2H 64GB 2933 2666 LRDIMM 3Ds 8Rx4 N A 4H 128GB 2933 2666 DDR4 Mem...

Страница 32: ...ards on both ends of the DIMM slot to unlock it 4 Align the key of the DIMM module with the receptive point on the memory slot 5 Align the notches on both ends of the module against the receptive poin...

Страница 33: ...cribed in Section 3 2 3 Attach the riser card to the riser card bracket using screws 4 Insert the riser card into the serverboard expansion slot while aligning the riser card bracket with the rear of...

Страница 34: ...battery slide one edge under the lip of the holder with the positive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the b...

Страница 35: ...ach HDD is inserted The backplane is located between the first and second rows of hard drives Replacing a Hard Drive 1 Power down the system as described in Section 3 1 and remove the front cover as d...

Страница 36: ...11 Replacing a Hard Drive Note Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information on recommended HDDs visit the Supermicro website at http www...

Страница 37: ...ture via BIOS If a fan fails the remaining fans will ramp up to full speed Replace any failed fan at your earliest convenience with the same type and model the system can continue to run with a failed...

Страница 38: ...38 Chapter 3 Maintenance and Component Installation Figure 3 12 System Fans lifted out of chassis...

Страница 39: ...n 3 1 2 Remove the two screws located at the middle of the power supply which secure it to the chassis You can then lift the module straight out of the chassis 3 Replace the failed unit with another u...

Страница 40: ...ply 24 pin Primary ATX Power JPWR3 8 pin Processor Power JPWR1 JPWR2 Main ATX Power Connector JPWR3 is the 24 pin ATX main power supply connector This primary power supply connector meets the ATX SSI...

Страница 41: ...or alternative single power source for a special enclosure when the 24 pin ATX power is not in use Refer to the table below for pin definitions 12V 8 pin Power Pin Definitions Pin Definition 1 4 Groun...

Страница 42: ...ntel RAID Key Pin Definitions Pins Definition 1 GND 2 PU 3 3V Stdby 3 GND 4 PCH RAID KEY Standby Power The Standby Power header is located at JSTBY1 on the motherboard You must have a card with a Stan...

Страница 43: ...ions Chassis Intrusion Pin Definitions Pin Definition 1 Intrusion Input 2 Ground NVMe I2 C Header Connector JNVI2 C1 and JNVI2 C2 are a management headers for the Supermicro AOC NVMe PCI E peripheral...

Страница 44: ...ctors I SATA 3 0 and S SATA 3 0 Ports The X11DDW L has eight I SATA 3 0 ports I SATA0 3 I SATA4 7 and six S SATA ports S SATA0 3 S SATA4 S SATA5 These SATA ports are supported by the Intel C621 chipse...

Страница 45: ...l 2 Ground Power Button The Power Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function as a...

Страница 46: ...ail and UID LED Connect an LED cable to pins 7 and 8 of the front control panel to use the Overheat Fan Fail LED connections The LED on pin 8 provides warnings of overheat or fan failure Refer to the...

Страница 47: ...JF1 Pins Definition 13 3 3V Stdby 14 HDD Active Power LED The Power LED connection is located on pins 15 and 16 of JF1 Refer to the table below for pin definitions Power LED Pin Definitions JF1 Pins D...

Страница 48: ...A display Unit Identifier Switch UID LED Indicator A Unit Identifier UID switch and indicator LE1 are located near theg rear I O ports When pressing the UID switch the UID LED indicator will be turned...

Страница 49: ...tion Pin Definition 1 VBUS 10 Power 2 D 11 USB 2 0 Differential Pair 3 D 12 4 Ground 13 Ground of PWR Return 5 StdA_SSRX 14 SuperSpeed Receiver 6 StdA_SSRX 15 Differential Pair 7 GND_DRAIN 16 Ground f...

Страница 50: ...Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally cleari...

Страница 51: ...r Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled Watch Dog JWD controls the Watch Dog function Watch Dog is a monitor that can reboot the system when a software application hang...

Страница 52: ...a host server to modify system settings See the table below for jumper settings Manufacturing Mode Select Jumper Settings Jumper Setting Definition Pins 1 2 Normal Default Pins 2 3 Manufacturing Mode...

Страница 53: ...LAN Activity LED Link LED LAN 1 LAN 2 IPMI LAN X8ST3 F BMC Heartbeat LED LEDM1 is the BMC heartbeat LED When the LED is blinking green BMC is functioning normally See the table below for the LED statu...

Страница 54: ...1 is located near the UID switch on the back panel This UID indicator provides easy identification of a system unit that may need service M 2 LED An M 2 LED is located at LE3 on the motherboard When L...

Страница 55: ...upermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive o...

Страница 56: ...ad the driver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID cho...

Страница 57: ...nother option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...

Страница 58: ...agement Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Management Server SSM Server y...

Страница 59: ...orm Management Interface IPMI IPMI is used to provide remote access monitoring and management There are several BIOS settings that are related to IPMI For general documentation and information on IPMI...

Страница 60: ...F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be co...

Страница 61: ...d time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press the Tab key or the arrow keys to move between fields The date must be entered in MM DD YYYY f...

Страница 62: ...62 SuperServer 6019P WT8 User s Manual Memory Information Total Memory This item displays the total size of memory available in the system...

Страница 63: ...feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal P...

Страница 64: ...and EFI Boot Install Windows 7 USB Support Enable this feature to use the USB keyboard and mouse during the Windows 7 installation since the native XHCI driver support is unavailable Use a SATA optic...

Страница 65: ...wer Fail Use this feature to decrease system power by throttling CPU frequency when one power supply has failed The options are Disabled and Enabled CPU Configuration Processor Configuration The follo...

Страница 66: ...he main memory to the L2 cache to improve CPU performance The options are Disable and Enable Adjacent Cache Prefetch Available when supported by the CPU The CPU prefetches the cache line for 64 bytes...

Страница 67: ...Processors In SW_ALL mode the OS Power Manager is responsible for coordinating the P state and must initiate the transition on all Logical Processors In SW_ANY mode the OS Power Manager is responsible...

Страница 68: ...ontrol Package C State This feature allows the user to set the limit on the C State package register The options are C0 C1 State C2 State C6 Non Retention State C6 Retention state No Limit and Auto CP...

Страница 69: ...updates Use this feature to lower cache to cache C2C transfer latencies The options are Disable Auto Enable for Remote InvItoM Hybrid Push InvItoM AllocFlow Enable for Remote InvItoM Hybrid AllocNonA...

Страница 70: ...This option allows the user to select 2X refresh mode The options are Auto Enabled and Disabled Memory Topology This feature displays DIMM population information Memory RAS Configuration Static Virtu...

Страница 71: ...DIMM or memory rank will then be disabled The options are Disable and Enable Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory mo...

Страница 72: ...ort 1A PcieBr1D01F0 Port 1B PcieBr2D00F0 Port 2A RSC R1UW 2E16 SLOT2 Link Speed Use this item to select the link speed for the PCI E port specified by the user The op tions are Auto Gen 1 2 5 GT s Gen...

Страница 73: ...Gen 3 8 GT s PCI E Port Max Payload Size Selecting Auto for this feature will enable the motherboard to automatically detect the maximum Transaction Layer Packet TLP size for the connected PCI E devi...

Страница 74: ...thout using a processor Select Enable to use the Non Isoch VT_D Engine Pass Through Direct Memory Access DMA support The options are Enable and Disable ATS Use this feature to enable Non Isoch VT d En...

Страница 75: ...ice above is set to Enable the following items will be dislayed VMD port 2A VMD port 2D Available when the device is detected by the system Select Enable to use the Intel Volume Management Device Tech...

Страница 76: ...spe cific root port The options are Disable and Enable Hot Plug Capable Available when the device is detected by the system Use this feature to enable hot plug support for PCIe root ports 1A 1D The o...

Страница 77: ...support for PCIe root ports 3A 3D The options are Disable and Enable PCI E Completion Timeout Disable Use this feature to enable PCI E Completion Timeout support for electric tuning The options are Y...

Страница 78: ...as an AHCI drive Select RAID to configure a SATA drive specified by the user as a RAID drive The options are IDE AHCI and RAID SATA HDD Unlock This feature allows the user to remove any password prot...

Страница 79: ...TA Controller This item enables or disables the onboard sSATA controller supported by the Intel PCH chip The options are Disable and Enable Configure sSATA as Select AHCI to configure an sSATA drive s...

Страница 80: ...e Hard Disk Drive and Solid State Drive PCIe PCI PnP Configuration The following information will display PCI Bus Driver Version PCI Devices Common Settings Above 4G Decoding Available if the system s...

Страница 81: ...ve The other option AMI Native Support is offered by the BIOS with a generic method VGA Priority Use this item to select the graphics device to be used as the primary video display for system boot The...

Страница 82: ...rk stack support The options are Enabled and Disabled If Network Stack is set to Enabled the following items will display Ipv4 PXE Support Use this feature to enable Ipv4 PXE Boot Support If this feat...

Страница 83: ...led Change Port 1 Settings This feature specifies the base I O port address and the Interrupt Request address of Serial Port 1 Select Auto for the BIOS to automatically assign the base I O and IRQ add...

Страница 84: ...le for user s configuration COM2 SOL Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer...

Страница 85: ...iving buffer is full Send a Start signal to start sending data when the receiving buffer is empty The options are None and Hardware RTS CTS VT UTF8 Combo Key Support Select Enabled to enable VT UTF8 C...

Страница 86: ...er set Select VT100 to add color and function key support Select ANSI to use the extended ASCII character set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The o...

Страница 87: ...a This setting Enables or Disables Non Uniform Memory Access NUMA a feature that improves memory to processor communication and performance The options are Enabled or Disabled WHEA Support Select Enab...

Страница 88: ...PT1 on the motherboard are both enabled the onboard security TPM device will be enabled in the BIOS to enhance data integrity and system security Please note that the OS will not show the security dev...

Страница 89: ...zation value both of which can be set and are held constant rarely changed through reboots This hierarchy can be cleared or changed independently of the other hierarchies The options are Enabled and D...

Страница 90: ...iguration iSCSI Initiator Name This feature allows the user to enter the unique name of the iSCSI Initiator in IQN format Once the name of the iSCSI Initiator is entered into the system configure the...

Страница 91: ...ng Settings Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next system reboot Select Yes Every Reset...

Страница 92: ...that a duplicate event must happen before the MECI counter is incremented This is a numeric value The default value is 1 METW The Multiple Event Time Window METW defines number of minutes must pass b...

Страница 93: ...irmware installed in your system System Event Log Enabling Disabling Options SEL Components Select Enabled for all system event logging at bootup The options are Enabled and Disabled Erasing Settings...

Страница 94: ...wing item will become available for user s configuration Configuration Address Source This feature allows the user to select the source of the IP address for this computer If Static is selected you wi...

Страница 95: ...ws the user to select the source of the IP address for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHC...

Страница 96: ...the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 characters long Password Check Select Setup for the system to check fo...

Страница 97: ...patibility Support Module CSM which provides compatibility support for traditional legacy BIOS for system boot The options are Enabled and Disabled Key Management This submenu allows the user to confi...

Страница 98: ...list to the existing KEK Select No to load the KEK from a file The options are Yes and No Authorized Signatures Set New Select Yes to load the database from the manufacturer s defaults Select No to lo...

Страница 99: ...lt key or load from a file The file formats accepted are 1 Public Key Certificate a EFI Signature List b EFI CERT X509 DER Encoded c EFI CERT RSA2048 bin d EFI SERT SHA256 bin 2 EFI Time Based Authent...

Страница 100: ...of a bootable device from which the system will boot Press Enter on each entry from top to bottom to select devices When the item above Boot Mode Select is set to Dual default the following items wil...

Страница 101: ...he name and the file path for the boot option are set press Enter to create the new boot option in the boot priority list Delete Boot Option This feature allows the user to select a boot device to del...

Страница 102: ...nd press Enter Save Changes and Reset After completing the system configuration changes select this option to save the changes you have made This will not reset reboot the system Save Changes When you...

Страница 103: ...er Defaults from the Save Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults fr...

Страница 104: ...oot up procedure If a fatal error occurs you should consult with your system manufacturer for possible repairs These fatal errors are usually communicated through a series of audible beeps The numbers...

Страница 105: ...m support manuals AMI BIOS POST Codes User s Guide When BIOS performs the Power On Self Test it writes checkpoint codes to I O port 0080h If the computer cannot complete the boot process a diagnostic...

Страница 106: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis The...

Страница 107: ...po considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontra...

Страница 108: ...en dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan h...

Страница 109: ...mentaci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het sy...

Страница 110: ...es del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l insta...

Страница 111: ...e energ a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me do...

Страница 112: ...bels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment War...

Страница 113: ...tention Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation...

Страница 114: ...a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s...

Страница 115: ...emblable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incor...

Страница 116: ...anbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All con...

Страница 117: ...omloos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Atte...

Страница 118: ...vertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques ci...

Страница 119: ...cumplir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is...

Страница 120: ...le elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled accordi...

Страница 121: ...recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving...

Страница 122: ...stornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient to...

Страница 123: ...UL oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro U...

Страница 124: ...le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto uti...

Страница 125: ...Aansluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storin...

Страница 126: ...x 3 5 and 2x 2 5 PCI Expansion Slots One PCI Express 3 0 x16 x16 slot supported by CPU1 and CPU2 for left riser card SXB1 One PCI Express 3 0 x16 slot supported by CPU2 for right riser card SXB2 One P...

Страница 127: ...IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU Delegated Directive EU 2015 863 and Directive 2012...

Страница 128: ...e The recovery block contains critical BIOS codes including memory detection and recovery codes for the user to flash a healthy BIOS image if the original main BIOS image is corrupted When the system...

Страница 129: ...ifferent machine copy the Super ROM binary image file into the Root directory of a USB device or a writable CD DVD Note 1 If you cannot locate the Super ROM file in your drive disk visit our website a...

Страница 130: ...if you want to start the BIOS recovery If you decide to proceed with BIOS recovery follow the procedures below 4 When the screen as shown above displays use the arrow keys to select the item Proceed w...

Страница 131: ...to enter the BIOS Setup utility From the top of the tool bar select Boot to enter the submenu From the submenu list select Boot Option 1 as shown below Then set Boot Option 1 to UEFI AP UEFI Built in...

Страница 132: ...terrupt this process until the BIOS flashing is complete 9 The screen above indicates that the BIOS update process is complete When you see the screen above unplug the AC power cable from the power su...