6-4
SUPERSERVER 6018TR-T/TF User's Manual
6-4 Air
Shrouds
Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC808 chassis air
shroud does not require screws to set up. The SC808 chassis requires two identical
air shrouds.
Installing an Air Shroud (Figure 6-3)
1. Confi rm that all six fans are in place and working properly
2. Place the fi rst air shroud into the chassis. The air shroud sits behind the
system fans. Each air shroud covers three fans.
3. Install the second air shroud in the same manner as the fi rst.
Figure 6-3: Installing the Air Shroud
6-5 Checking
the
Airfl ow
Checking Airfl ow
1. Make sure there are no objects obstructing airfl ow in and out of the server. In
addition, if you are using a front bezel, make sure the bezel's fi lter is replaced
periodically.
2. Do not operate the server without drives or drive carriers in the drive bays.
Use only recommended server parts.
3. Make sure no wires or foreign objects obstruct air fl ow through the chassis.
Pull all excess cabling out of the airfl ow path or use shorter cables.
4. The control panel LEDs inform you of system status. See “Chapter 3: System
Interface” for details on the LEDs and the control panel buttons.
Содержание SUPERSERVER 6018TR-T
Страница 1: ...SUPERSERVER 6018TR T 6018TR TF USER S MANUAL Revision 1 0...
Страница 5: ...v SUPERSERVER 6018TR T TF User s Manual Notes...
Страница 10: ...x Notes SUPERSERVER 6018TR T TF User s Manual...
Страница 84: ...5 32 SUPERSERVER 6018TR T TF User s Manual Notes...
Страница 98: ...6 14 SUPERSERVER 6018TR T TF User s Manual Release Tab Figure 6 14 Changing the Power Supply...
Страница 140: ...A 2 SUPERSERVER 6018TR T TF User s Manual Notes...