2-4
S
UPER
S
ERVER 6014H-i2/6014H-i/6014H-Xi Manual
2-4
Installing the System into a Rack
This section provides information on installing the SuperServer 6014H-i2/
6014H-i/6014H-Xi into a rack unit with the rack rails provided. If the server
has already been mounted into a rack, you can skip ahead to Sections 2-5
and 2-6. There are a variety of rack units on the market, which may mean
the assembly procedure will differ slightly. You should also refer to the
installation instructions that came with the rack unit you are using.
Identifying the Sections of the Rack Rails
You should have received two rack rail assemblies with the SuperServer
6014H-i2/6014H-i/6014H-Xi. Each of these assemblies consists of two sec-
tions: an inner fixed chassis rail that secures to the chassis and an
outer fixed rack rail that secures directly to the rack itself. Two pairs of
short brackets to be used on the front side of the outer rails are also
included.
Installing the Inner Rails
First, locate the right inner rail (the rail that will be used on the right side
when you face the front of the chassis). Align the four square holes on
the right inner rail against the hooks on the right side of the chassis.
Securely attach the rail to the chassis with two M4 flat head screws.
Repeat these steps to install the left inner rail to the left side of the chassis.
Installing the Outer Rails
Begin by measuring the distance from the front rail to the rear rail of the
rack. Attach a short bracket to the front side of the right outer rail and a
long bracket to the rear side of the right outer rail. Adjust both the short
and long brackets to the proper distance so that the rail can fit snugly into
the rack. Secure the short bracket to the front side of the outer rail with
two M4 screws and the long bracket to the rear side of the outer rail with
three M4 screws. Repeat these steps for the left outer rail.
Содержание SuperServer 6014H-i
Страница 1: ...SUPERSERVER 6014H i2 SUPERSERVER 6014H i SUPERSERVER 6014H Xi USER SMANUAL 1 0a SUPER...
Страница 5: ...v Preface Notes...
Страница 10: ...SUPERSERVER 6014H i2 6014H i 6014H Xi Manual x Notes...
Страница 30: ...3 4 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...
Страница 65: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 4 Removing an IDE Drive from the Chassis...
Страница 68: ...6 10 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...
Страница 96: ...A 6 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...
Страница 102: ...B 6 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...
Страница 126: ...D 4 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...