Creating Arrays
Before creating arrays, make sure the disks for the array are connected
and installed in your system. Note that disks with no usable space, or
disks that are un-initialized are shown in gray and cannot be used. See
Initializing Disk Drives
.
To create an array
1. Turn on your computer and press
Ctrl+A
when prompted to access
the ARC utility.
2. From the ARC menu, select
Array Configuration Utility Main Menu
(ACU)
(as shown on the first screen on page B-4).
3. From the ACU menu select
Create Array
.
4. Select the disks for the new array and press
Insert
(as shown on the
the screen below).
Note:
To deselect any disk, highlight the disk and press
Delete
.
5.
Press
Enter
when both disks for the new array are selected. The
Array Properties menu displays (as the shown on the screen on the next
page).