Страница 1: ...SUPERSERVER 6014H i2 SUPERSERVER 6014H i SUPERSERVER 6014H Xi USER SMANUAL 1 0a SUPER...

Страница 2: ...R INABILITY TO USE THIS PRODUCT OR DOCUMENTATION EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN PARTICULAR THE VENDOR SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED W...

Страница 3: ...ain features of the X6DHR iG2 X6DHR iG X6DHR XiG serverboard and the SC812i 420 chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 6014H i2 601...

Страница 4: ...ter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC812i 420 1U rackmount server chassis You should follow the procedures given in this chapter when installing removing o...

Страница 5: ...v Preface Notes...

Страница 6: ...Location 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 2 4 Installing the System into a Rack 2 4 Identifying the Sections of the Rack Rails 2 4 Installing the Inner...

Страница 7: ...7 5 5 Installing Memory 5 7 5 6 Adding PCI Cards 5 9 5 7 Serverboard Details 5 10 X6DHR iG2 Layout 5 10 X6DHR iG2 Quick Reference 5 11 X6DHR iG X6DHR XiG Layout 5 12 X6DHR iG X6DHR XiG Quick Referenc...

Страница 8: ...2 GLAN LEDs 5 22 5 11 Floppy and Hard Disk Drive Connections 5 23 Floppy Connector 5 23 IDE Connectors 5 24 Chapter 6 Advanced Chassis Setup 6 1 Static Sensitive Devices 6 1 6 2 Control Panel 6 2 6 3...

Страница 9: ...etup Menu 7 3 7 4 Advanced Setup 7 7 7 5 Security 7 18 7 6 Boot 7 20 7 7 Exit 7 21 Appendices Appendix A BIOS POST Messages A 1 Appendix B BIOS POST Codes B 1 Appendix C Software Installation C 1 Appe...

Страница 10: ...SUPERSERVER 6014H i2 6014H i 6014H Xi Manual x Notes...

Страница 11: ...supermicro com In addition to the serverboard and chassis various hardware components may have been included with your SuperServer 6014H i2 6014H i 6014H Xi as listed below z Two 2 10 cm system blowe...

Страница 12: ...as been designed to support 2 GB DIMM modules for each memory slot but it has only been validated with 1 GB memory modules The X6DHR iG X6DHR XiG has eight 184 pin DIMM slots that can support up to 16...

Страница 13: ...e this is a general chipset block diagram Please refer to sections 1 2 and 1 3 in this chapter and Chapter 5 for details on each server system Onboard Controllers Ports The X6DHR iG2 X6DHR iG X6DHR Xi...

Страница 14: ...ately may be added to support the use of two x8 PCI Express cards See section 5 6 for details on riser cards The 6014H i has two Universal PCI X 133 MHz PCI Express x8 x4 slots Included riser cards su...

Страница 15: ...chassis revolutionary cooling design has been optimized to provide sufficient cooling for dual Xeon configurations in a 1U space The SC812i 420 includes two heavy duty 10 cm blower fans located in the...

Страница 16: ...Europe Address SuperMicro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support superm...

Страница 17: ...it was damaged in any way If the server itself shows damage you should file a damage claim with the carrier who deliv ered it Decide on a suitable location for the rack unit that will hold the SuperS...

Страница 18: ...acks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more simultaneously may c...

Страница 19: ...omised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical loading Circuit Overloading Consideration should be given to the...

Страница 20: ...f Two pairs of short brackets to be used on the front side of the outer rails are also included Installing the Inner Rails First locate the right inner rail the rail that will be used on the right sid...

Страница 21: ...er into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place when fully extended from the rack This prevents the server fr...

Страница 22: ...ll the server into the rack Do this by lining up the rear of the chassis rails with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you...

Страница 23: ...ck If you are installing the SuperServer 6014H i2 6014H i 6014H Xi into a Telco type rack follow the directions given on the previous pages for rack instal lation The only difference in the installati...

Страница 24: ...to gain full access to the inside of the server 2 Check the CPUs processors You should have one or two processors already installed into the serverboard Each processor needs its own heatsink See Chap...

Страница 25: ...airflow Make sure all power and data cables are properly connected and not blocking the chassis airflow See Chapter 5 for details on cable connec tions Also check the air seals for damage The air seal...

Страница 26: ...IDE disk drives Depending upon your system s configuration your system may have one or more drives already installed If you need to install IDE drives please refer to Chapter 6 4 Check the airflow Ai...

Страница 27: ...e meanings of the control panel LED indicators and the appropriate response you may need to take when one turns on 3 2 Control Panel Buttons There are two push buttons located on the front of the chas...

Страница 28: ...may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are present and operating normally Y...

Страница 29: ...Chapter 3 System Interface 3 3 z Power Indicates power is being supplied to the system s power supply units This LED should normally be illuminated when the system is operating...

Страница 30: ...3 4 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...

Страница 31: ...erboard memory modules and the CD ROM and floppy drives When disconnecting power you should first power down the system with the operating system and then unplug the power cords of all the power suppl...

Страница 32: ...ome into contact with electrical circuits or be pulled into a cooling fan z Remove any jewelry or metal objects from your body which are excellent metal conductors that can create short circuits and h...

Страница 33: ...Touch a grounded metal object before removing any board from its antistatic bag z Do not let components or PCBs come into contact with your clothing which may retain a charge even if you are wearing...

Страница 34: ...sis cover is in place when the 6014H i2 6014H i 6014H Xi is operating to ensure proper cooling Out of warranty damage to the 6014H i2 6014H i 6014H Xi system can occur if this practice is not strictly...

Страница 35: ...that the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board t...

Страница 36: ...CPU socket when power is applied In stall CPU1 first IMPORTANT Always connect the power cord last and always remove it before adding removing or changing any hardware components Make sure that you ins...

Страница 37: ...the screws to avoid possible damage to the CPU Screw in the two remaining screws until snug see Figure 5 2 4 Finish the installation by fully tightening all four screws The heatsink package SNK P0009...

Страница 38: ...quence as show in the picture above 2 Hold the heatsink and gently wiggle it back and forth to loosen it from the CPU Do not use excessive force when loosening the heatsink 3 Once the heatsink has bee...

Страница 39: ...uring the sys tem keep the airflow in mind when routing the cables The following data cables with their serverboard connector locations noted should be connected See the serverboard layout figure in t...

Страница 40: ...ch header All JF1 wires have been bundled into single ribbon cable to simplify their connection Make sure the red wire plugs into pin 1 as marked on the board The other end connects to the Control Pan...

Страница 41: ...ules to prevent any possible damage Also note that the memory is interleaved to improve performance see step 1 DIMM Installation See Figures 5 5a and 5 5b 1 Insert the desired number of DIMMs into the...

Страница 42: ...gistered ECC DDR2 400 SDRAM The serverboard has has been de signed to support 2 GB DIMM modules for each memory slot but it has only been validated with 1 GB memory modules The X6DHR iG X6DHR XiG has...

Страница 43: ...is server support the use of two one standard and one low profile PCI X cards of any speed Riser Cards Standard Slot Add on Card CSE RR1U X PCI X L PCI X CSE RR1U XLP SXB E R PCI X low profile Riser C...

Страница 44: ...to scale DIMM 4B USB 0 1 COM1 DIMM 4A DIMM 3B DIMM 3A DIMM 2B DIMM 2A DIMM 1B DIMM 1A GLAN1 GLAN2 VGA Battery RAGE XL P X H PCI X 133 MHz PCI X 100 MHz E7520 ICH5R IDE 1 IDE 2 Floppy WOL COM2 FAN3 BI...

Страница 45: ...RAM Slots FAN 1 5 Onboard CPU Fan Chassis Fan Headers GLAN1 2 Gigabit Ethernet Ports J3 J4 Serial ATA Connectors J5 J6 IDE1 2 Hard Disk Drive Connectors J9 IPMI 2 0 Connector J11 System Management Bus...

Страница 46: ...I 2 0 BIOS SI O IDE 1 IDE 2 Floppy COM2 JD2 JP9 Force PW On WOR JBT1 FAN5 J4 J3 JF1 FAN2 FAN1 JL1 JWD CPU1 CPU2 JP11 OH J14 JD1 J5 J6 J12 FAN4 J1B1 J1D1 J38 J32 Notes 1 Jumpers not indicated are for m...

Страница 47: ...Fan Headers GLAN1 2 Gigabit Ethernet Ports J3 J4 SATA0 1 Connectors J5 J6 IDE1 2 Hard Disk Drive Connectors J9 IPMI 2 0 Connector J11 System Management Bus Header J12 Floppy Drive Connector J32 SMB P...

Страница 48: ...efinition Ground 12 V 12V 4 pin Connector J38 Required Connection Processor Power Connector In addition to the Primary ATX power connector above the 12v 8 pin processor power connector at J1D1 must al...

Страница 49: ...es to display network ac tivity Refer to the table on the right for pin definitions NIC1 2 LED Pin Definitions JF1 Pin Number 9 11 10 12 Definition Vcc GND Overheat OH LED Pin Definitions JF1 Pin Numb...

Страница 50: ...2 3 can be used to provide front side chassis access cables not included See the tables on the right for pin defi nitions Chassis Intrusion A Chassis Intrusion header is lo cated at JL1 Attach the app...

Страница 51: ...AN1 FAN5 on the serverboard See the table on the right for pin defini tions Note These fan headers are 4 pin fans Pins 1 3 of the fan headers are backward compatible with traditional 3 pin fans Fan sp...

Страница 52: ...aker data Wake On Ring The Wake On Ring header desig nated JWOR allows your computer to receive and wake up by an in coming call to the modem when in suspend state See the table on the right for pin d...

Страница 53: ...ilable when using redundant Supermicro power supplies SMB I2 C Connector An I2 C connector at J11 located near the battery on the X6DHR iG2 and near the IPMI header on the X6DHR iG X6DHR XiG monitors...

Страница 54: ...ed means the jumper is on and Open means the jumper is off the pins Connector Pins Jumper Cap Setting Pin 1 2 short 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any password...

Страница 55: ...ng with JP10 to prevent false alarms See the table on right for pin definitions Jumper Position Open Closed Definition Disabled Enabled Power Supply Alarm Enable Disable Jumper Settings JP10 Watch Dog...

Страница 56: ...ct the speed of the system memory See the table on the right for jumper definitions The default setting is closed DDR333 Note if these jumpers are not set correctly you may experience problems with yo...

Страница 57: ...Floppy Connector Pin Definitions J12 Floppy Connector The floppy connector is located on J12 See the table below for pin definitions 5 11 Floppy and Hard Disk Drive Connections Note the following whe...

Страница 58: ...4 11 Host Data 3 13 Host Data 2 15 Host Data 1 17 Host Data 0 19 GND 21 DRQ3 23 I O Write 25 I O Read 27 IOCHRDY 29 DACK3 31 IRQ14 33 Addr 1 35 Addr 0 37 Chip Select 0 39 Activity Pin Number Function...

Страница 59: ...ge to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions z Use a ground...

Страница 60: ...verboard to the appro priate header on the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the airflow path The contro...

Страница 61: ...ing fan removing the power cord is also recommended as a safety precaution Replacing System Cooling Fans 1 Removing a fan After first turning off the power to the system remove the chassis cover and u...

Страница 62: ...is you must first remove it to gain access to the drive bays To remove the bezel first unlock the front of the chassis then press the release knob Carefully remove the bezel with both hands A filter l...

Страница 63: ...cess to the inside of the system Proceed to the CD ROM and Floppy Drive Installation section later in this chapter for in structions Note Only a slim type CD ROM and floppy drive will fit into the 601...

Страница 64: ...t the mounting holes align with those in the carrier Secure the drive to the carrier with four screws as shown in Figure 6 3 2 Installing removing IDE drives The three IDE drive bays are located in th...

Страница 65: ...Chapter 6 Advanced Chassis Setup 6 7 Figure 6 4 Removing an IDE Drive from the Chassis...

Страница 66: ...n full access to the inside of the server With the chassis cover removed unplug the power and data cables from the drive you want to remove Then locate the locking tab at the rear of the drive It will...

Страница 67: ...ove the top cover To remove the top chassis cover press the two release buttons on the cover near the front and then push the cover rearward about one inch before lifting it off Locate the power conne...

Страница 68: ...6 10 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...

Страница 69: ...displays all the options that can be configured Grayed out options cannot be configured The right frame displays the key legend Above the key legend is an area reserved for a text message When an opt...

Страница 70: ...1 By pressing Delete immediately after turning the system on or 2 When the message shown below appears briefly at the bottom of the screen during the POST Power On Self Test press the Delete key to a...

Страница 71: ...in the correct information in the appropriate fields Then press the Enter key to save the data System Date Using the arrow keys highlight the month day and year fields and enter the correct data Pres...

Страница 72: ...able Serial ATA RAID Functions For the Windows OS environment use the RAID driver if this feature is set to Enabled If disabled use the Non RAID driver Native Mode Operation This option allows the use...

Страница 73: ...ct a predetermined type of hard drive CD ROM and ATAPI Removable The option User will allow the user to enter the parameters of the HDD installed at this connection The option Auto will allow BIOS to...

Страница 74: ...ts 32 Bit I O operation The options are Enabled and Disabled Transfer Mode Selects the transfer mode The options are Standard Fast PIO1 Fast PIO2 Fast PIO3 Fast PIO4 FPIO3 DMA1 and FPIO4 DMA2 Ultra DM...

Страница 75: ...highlighting the setting option using the arrow keys and pressing Enter All Advanced BIOS Setup options are described in this section Boot Features Access the submenu to make changes to the following...

Страница 76: ...s after an unexpected loss of power The options are Stay On Power Off and Last State Watch Dog Use this setting to Enable or Disable the Watch Dog feature Summary Screen This setting allows you to Ena...

Страница 77: ...Uncached to disable this funciton Select Write Through to allow data to be cached into the buffer and written into the system memory at the same time Select Write Protect to prevent data from being w...

Страница 78: ...s frequency for the devices installed in the slot indicated The options are Auto PCI 33 MHz PCI 66 MHz PCI X 66 MHz PCI X 100 MHz and PCI X 133 MHz Frequency for G LAN This option allows the user to c...

Страница 79: ...Clock rate The options are Default 0020h 0040h 0060h 0080h 00A0h 00C0h and 00E0h For Unix Novell and other Operating Systems please select the option other If a drive fails after the installation of...

Страница 80: ...setting specifies the conditions required to be qualified as an ECC error The options are None Single Bit Multiple Bit and Both USB Function This setting allows you to Enable or Disable all functions...

Страница 81: ...e the function of hyper threading Enabling hyper threading results in increased CPU performance Applicable for the XP systems Machine Checking This setting allows you to Enable or Disable Machine Chec...

Страница 82: ...s are 3F8 2F8 3E8 and 2E8 Interrupt Select the IRQ interrupt request for serial port A The options are IRQ3 and IRQ4 On board COM 2 This setting allows you to assign control of serial port B The optio...

Страница 83: ...rrupt request for the parallel port The options are IRQ5 and IRQ7 Mode Specify the parallel port mode The options are Output Only Bi directional EPP and ECP DMA Channel 1 Specify the DMA channel The o...

Страница 84: ...ontents of the event log Event Logging This setting allows you to Enable or Disable event logging ECC Event Logging This setting allows you to Enable or Disable ECC event logging Mark DMI Events as Re...

Страница 85: ...llows the user to decide how the system controls the speeds of the onboard fans If the option is set to 3 pin the fan speed is con trolled based upon the CPU die temperature When the CPU die temperatu...

Страница 86: ...ssing Enter All Security BIOS settings are described in this section Supervisor Password Is This displays whether a supervisor password has been entered for the system Clear means such a password has...

Страница 87: ...en prompted type the user s password in the dialogue box to set or to change the user s password which allows access to the system at boot up Fixed Disk Boot Sector This setting may offer some protect...

Страница 88: ...ress Enter to expand the field See details on how to change the order and specs of devices in the Item Specific Help window CD ROM Drive See details on how to change the order and specs of the CD ROM...

Страница 89: ...t Saving Changes Highlight this item and hit Enter to save any changes you made and to exit the BIOS Setup utility Exit Discarding Changes Highlight this item and hit Enter to exit the BIOS Setup util...

Страница 90: ...anual Discard Changes Highlight this item and hit Enter to discard cancel any changes you made You will remain in the Setup utility Save Changes Highlight this item and hit Enter to save any changes y...

Страница 91: ...ed Keyboard controller failed test May require replacing keyboard controller Keyboard locked Unlock key switch Unlock the system to proceed Monitor type does not match CMOS Run SETUP Monitor type not...

Страница 92: ...Previous POST did not complete successfully POST loads default values and offers to run Setup If the failure was caused by incorrect values and they are not corrected the next boot will likely fail O...

Страница 93: ...tware NMI Failed ServerBIOS2 test error Cannot generate software NMI Non Maskable Interrupt Fail Safe Timer NMI Failed ServerBIOS2 test error Fail Safe Timer takes too long device Address Conflict Add...

Страница 94: ...uccessfully tested nnnn kB System RAM Passed Where nnnn is the amount of system RAM in kilobytes successfully tested One or more I2O Block Storage Devices were excluded from the Setup Boot Menu There...

Страница 95: ...Write down and follow the information shown on the screen Press F2 to enter Setup Optional message displayed during POST Can be turned off in Setup PS 2 Mouse PS 2 mouse identified Run the I2O Configu...

Страница 96: ...A 6 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...

Страница 97: ...rite the error in the top left corner of the screen The following is a list of codes that may be written to port 80h Appendix B BIOS POST Codes POSTCode Description 02h Verify Real Mode 03h Disable No...

Страница 98: ...n 38h Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced configuration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory for RomPilot 42h Initializ...

Страница 99: ...80h Disable onboard Super I O ports and IRQs 81h Late POST device initialization 82h Detect and install external RS232 ports 83h Configure non MCD IDE controllers 84h Detect and install external paral...

Страница 100: ...rminate QuietBoot optional B6h Check password optional B7h Initialize ACPI BIOS B9h Prepare Boot BAh Initialize SMBIOS BBh Initialize PnP Option ROMs BCh Clear parity checkers BDh Display MultiBoot me...

Страница 101: ...ory size EEh Shadow Boot Block EFh System memory test F0h Initialize interrupt vectors F1h Initialize Run Time Clock F2h Initialize video F3h Initialize System Management Manager F4h Output one beep F...

Страница 102: ...B 6 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...

Страница 103: ...e tradi tional cables used in Parallel ATA PATA SATA systems have better air flow and can be installed in smaller chassis than Parallel ATA In addition the cables used in PATA can only extend to 40cm...

Страница 104: ...systems by improving disk I O throughput and providing data accessibility regardless of a single disk failure By incorporating Adaptec Embedded Serial ATA into the motherboard design Supermicro offers...

Страница 105: ...S Utility in cluding Array Configuration Utility Use this utility when you want to create configure and manage arrays Disk Utilities Use this option to format or verify disks To run the Adaptec RAID C...

Страница 106: ...g Arrays Select this option to view array properties and delete arrays The follow ing sections describe the operations Of Managing Arrays To select this option use the arrow keys and the Enter key to...

Страница 107: ...array before you delete it to prevent the loss of data Deleted arrays cannot be restored 1 Turn on your computer and press Ctrl A when prompted to access the ARC utility 2 From the ARC main menu selec...

Страница 108: ...1 Turn on your computer and press Ctrl A when prompted to access the ARC utility 2 From the ARC menu select Array Configuration Utility Main Menu ACU as shown on the first screen on page B 4 3 From th...

Страница 109: ...ide in the enclosed CD To assign properties to the new array 1 In the Array Properties menu as shown on the following screen select an array type and press Enter Note that only the available array typ...

Страница 110: ...0 Migrate Note Creating a RAID 0 from one new drive and one drive with data you wish to preserve RAID 1 Build1 Any time you wish to create a RAID 1 but especially if you have data on one drive that y...

Страница 111: ...ws you to use drives of different sizes in a RAID However during a build operation only the smaller drive can be selected as the source or first drive 5 When migrating from single volume to RAID 0 mig...

Страница 112: ...will then be created An asterisk will appear next to the bootable array Deleting a Bootable Array To delete a bootable array 1 From the Main menu select Manage Arrays 2 From the List of Arrays select...

Страница 113: ...ss the ARC Utility 2 From the ARC menu select Array Configuration Utility ACU 3 From the ACU menu select Add Delete Hotspares 4 Use the up and down arrow keys to highlight and select the disk you want...

Страница 114: ...and makes any data on the disk inaccessible If the drive is used in an array you may not be able to use the array again Do not initialize a disk that is part of a boot array To determine which disks...

Страница 115: ...Appendix C Software Installation C 13 5 Repeat Step 4 so that both drives to be initialized are selected as shown on the following screen...

Страница 116: ...rray rebuild operation the optimal drive is the source drive Note 2 If no spare array exists and a hard disk drive fails you need to create a spare before you can rebuild an array To Rebuild an array...

Страница 117: ...isk Utilities 3 Select the desired disk and press Enter as shown below You can choose from the following options 1 Format Disk Simulates a low level format of the hard drive by writing zeros to the en...

Страница 118: ...configurations press ESC to exit The following screen will appear For more information regarding the Adaptec RAID Utility please refer to Adaptec s User s Guide in the CD included in your ship ping pa...

Страница 119: ...Press F6 if you need to install a third party SCSI or RAID driver is displayed 8 When the Windows OS Setup screen appears press S to specify additional device s 9 Insert the driver diskette labelled A...

Страница 120: ...which are optional The bottom icon with a CD on it allows you to view the entire contents of the CD Note Please refer to the Adaptec User s Guide included in the CD for installing the Adaptec SATA RA...

Страница 121: ...ed SD III Client The Supero Doctor III program included on the CDROM that came with your motherboard allows you to monitor the environment and operations of your system Supero Doctor III dis plays cru...

Страница 122: ...trol Display Note SD III Software Revision 1 0 can be downloaded from our Web site at ftp ftp supermicro com utility Supero_Doctor_III You can also download the SDIII User s Guide at http www supermic...

Страница 123: ...porting up to 16 GB of low profile registered ECC DDR333 SDRAM or 32GB of low profile registered ECC DDR266 SDRAM Note Interleaved memory requires memory to be installed two at a time See the memory s...

Страница 124: ...cm blower fans fan speed controlled by BIOS setting System Input Requirements AC Input Voltage 100 240V AC auto range Rated Input Current 7A max Rated Input Frequency 50 to 60 Hz Power Supply Rated Ou...

Страница 125: ...55022 Class B EN 61000 3 2 EN 61000 3 3 CISPR 22 Class B Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety E...

Страница 126: ...D 4 SUPERSERVER 6014H i2 6014H i 6014H Xi Manual Notes...