background image

114

113

SuperServer 5019S-MN4 User's Manual

Appendix B: Standardized Warning Statements

Warnung
Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen 
wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des 
Lüftergehäuses entfernt.

¡Advertencia! 

Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis. 
Mandtenga  los  dedos,  los  destornilladores  y  todos  los  objetos  lejos  de  las  aberturas  del 

ventilador

Attention 

Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc 
ventilateur du châssis. Prenez garde à ce que doigts, tournevis et autres objets soient éloignés 

du logement du bloc ventilateur.

!הרהזא

 

יקלח תא םיריסמ רשאכ

 

 שי .םידבוע ןיידע םיררוואמהו ןכתי ,זראמהמ ררוואמה

 קיחרהל

ל

ררוואמה ךותב םיחתפהמ םינוש הדובע ילכו תועבצאה תא חוטב קחרמ

 

 

هكممنا هم

 

حوارمنا نأ

 

لاست لا

 

ةنازإ دنعرودت

 

ةهتك

 

ةحورمنا

 

مكيهنا هم

 

بجي

 

ءاقبإ

 

عباصلأا

 

و

يغاربنا تاكفم

 

.

ءايشلأا هم اهريغو

 

اديعب

 

هع

 

تاحتفنا

 

يف

 

ةهتك

 

ةحورمنا

  

 

 

경고!

섀시로부터 팬 조립품을 제거할 때 팬은 여전히 회전하고 있을 수 있습니다. 팬 조림품 
외관의 열려있는 부분들로부터 손가락 및 스크류드라이버, 다른 물체들이 가까이 하지 
않도록 배치해 주십시오. 

Waarschuwing

Het is mogelijk dat de ventilator nog draait tijdens het verwijderen van het ventilatorsamenstel 

uit het chassis. Houd uw vingers, schroevendraaiers en eventuele andere voorwerpen uit de 
buurt van de openingen in de ventilatorbehuizing.

Power Cable and AC Adapter 

Warnung 
Bei der Installation des Produkts, die zur Verfügung gestellten oder benannt Anschlusskabel, 
Stromkabel und Netzteile. Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion 
oder ein Brand entstehen. Elektrische Geräte und Material Safety Law verbietet die 

Verwendung von UL-oder CSA-zertifizierte Kabel, UL oder CSA auf der Code für alle anderen 

elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben.

¡Advertencia! 
Al instalar el producto, utilice los cables de conexión previstos o designados, los cables y 
adaptadores de CA. La utilización de otros cables y adaptadores podría ocasionar un mal 
funcionamiento o un incendio. Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe 

el uso de UL o CSA cables certificados que tienen UL o CSA se muestra en el código de 

otros dispositivos eléctricos que los productos designados por Supermicro solamente.

電源コードとACアダプター
製品を設置する場合、提供または指定された接続ケーブル、電源コードとACアダプターを使用下さ
い。 他のケーブルやアダプタを使用すると故障や火災の原因になることがあります。 電気用品安全
法は、ULまたはCSA認定のケーブル(UL/CSEマークがコードに表記)を  Supermicroが指定する製
品以外に使用することを禁止しています。

警告
安装此产品时,请使用本身提供的或指定的连接线,电源线和电源适配器.使用其它线材或适配
器可能会引起故障或火灾。除了Supermicro所指定的产品,电气用品和材料安全法律规定禁止
使用未经UL或CSA认证的线材。(线材上会显示UL/CSA符号)。

警告
安裝此產品時,請使用本身提供的或指定的連接線,電源線和電源適配器.使用其它線材或適配
器可能會引起故障或火災。除了Supermicro所指定的產品,電氣用品和材料安全法律規定禁止
使用未經UL或CSA認證的線材。(線材上會顯示UL/CSA符號)。

Warning! 

When installing the product, use the provided or designated connection 

cables, power cables and AC adaptors. Using any other cables and adaptors could 

cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits 
the use of UL or  CSA -certified cables (that have  UL/CSA shown on the code) for any 

other electrical devices than products designated by Supermicro only.

Содержание SuperServer 5019S-MN4

Страница 1: ...nce when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s...

Страница 2: ...se check the Supermicro website for possible updates to the manual revision level Warnings Special attention should be given to the following symbols used in this manual Warning Indicates high voltage...

Страница 3: ...r 4 Motherboard Connections 4 1 Power Connections 42 4 2 Headers and Connectors 43 Control Panel 48 Data Cables 51 Power Cables 51 4 3 Ports 52 Rear I O Ports 52 4 4 Jumpers 55 Explanation of Jumpers...

Страница 4: ...V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermi...

Страница 5: ...AC power outlet nearby Be sure to read the precautions and considerations noted in Appendix B Main Parts List Description Part Number Quantity Air Shroud MCP 310 19007 0N 1 Heatsink passive SNK P0046...

Страница 6: ...m the power supply to the server Turning off system power with this button removes the main power but maintains standby power To perform many maintenance tasks you must also unplug system before servi...

Страница 7: ...s 1 4 4 3 2 Figure 1 4 Motherboard Layout 1 5 Motherboard Layout Below is a layout of the X11SSH LN4F with jumper connector and LED locations shown See the table on the following pages for description...

Страница 8: ...Intel PCH 6Gb s I SGPIO 1 2 Serial_Link General Purpose I O Connection Headers 1 2 IPMI_LAN Dedicated IPMI Gigabit RJ45 Port J23 M 2 Socket JD1 Speaker Power LED Indicator JF1 Front Panel Control Head...

Страница 9: ...anual Figure 1 5 C236 Chipset Block Diagram Note This is a general block diagram and may not exactly represent the features on your motherboard See the System Specifications appendix for the actual sp...

Страница 10: ...on the bottom of the rack are extended to the floor so that the full weight of the rack rests on them In single rack installations stabilizers should be attached to the rack In multiple rack in stall...

Страница 11: ...3 Installing the Rails There are a variety of rack units on the market which may require a slightly different assembly procedure The following is a basic guideline for installing the system into a rac...

Страница 12: ...addition these tabs lock the server in place when fully extended from the rack This prevents the server from coming completely out of the rack when pulled out for servicing Figure 2 1 Installing the R...

Страница 13: ...hassis four total 1 First determine how far the server will extend out from the front of the rack The chassis should be positioned so that the weight is balanced between front and back 2 Attach the tw...

Страница 14: ...the inside of the chassis Removing the Top Cover 1 Disconnect the chassis from any power source if necessary see above 2 Remove the screws securing the cover to the chassis 3 Slide the cover toward th...

Страница 15: ...ponents 5 With the processor inserted into the socket inspect the four corners of the CPU to make sure that it is properly installed and flush with the socket Figure 3 5 Installing Removing the Heatsi...

Страница 16: ...ocket 1 Unscrew and remove the heatsink screws from the motherboard in the sequence as show in the figure above 2 Hold and gently pivot the heatsink back and forth to loosen it from the CPU Do not use...

Страница 17: ...le damage to the DIMMs or slots Release Tabs Notches Press both notches straight down into the memory slot Note Visit the product page on the Supermicro website for possible updates to memory support...

Страница 18: ...attery is installed upside down which reverses its polarities This battery must be replaced only with the same or an equivalent type recommended by the manufacturer CR2032 Figure 3 11 Removing a Drive...

Страница 19: ...is very important that the chassis top cover is installed for the cooling air to circulate properly through the chassis and cool the components Installing Fans Fan speed is controlled by system temper...

Страница 20: ...ement units can be ordered directly from Supermicro see contact information in the Preface Removing the Power Supply Begin by removing power from the system as described in Section 3 1 1 Releasing the...

Страница 21: ...o the power supply Failure to do so may void the manufacturer s warranty on your power supply and motherboard ATX Power 24 pin Connector Pin Definitions Pin Definition Pin Definition 13 3 3V 1 3 3V 14...

Страница 22: ...on Disk On Module Power Connector Two power connectors for SATA DOM Disk On Module devices are located at JSD1 JSD2 Connect appropriate cables here to provide power support for your Serial Link DOM de...

Страница 23: ...sion Pin Definitions Pin Definition 1 Intrusion Input 2 Ground M 2 Slot The X11SSH LN4F contains one M 2 socket at J23 M 2 was formerly Next Generation Form Factor NGFF and serves to replace mini PCI...

Страница 24: ...wer Button connection is located on pins 1 and 2 of JF1 Momentarily contacting both pins will power on off the system This button can also be configured to function as a suspend button with a setting...

Страница 25: ...nitions HDD LED Pin Definitions JF1 Pin Definition 13 3 3V Standby UID Switch 14 HDD Active Power LED The Power LED connection is located on pins 15 and 16 of JF1 Power LED Pin Definitions JF1 Pin Def...

Страница 26: ...4 USB0 2 0 8 LAN2 Port 12 UID Switch 1 9 8 7 6 5 4 3 2 10 12 11 Back Panel USB 0 1 2 0 Pin Definitions Pin Definition Pin Definition 1 5V 5 5V 2 USB_N 6 USB_N 3 USB_P 7 USB_P 4 Ground 8 Ground Univers...

Страница 27: ...ard layout page for jumper locations Note On a two pin jumper Closed means the jumper is on both pins and Open indicates the jumper is either on only one pin or has been completely removed Connector P...

Страница 28: ...Definition Pins 1 2 Reset Pins 2 3 NMI Open Disabled BIOS Recovery Use jumper JBR1 to recover the BIOS settings on the motherboard The default setting is Normal BIOS Recovery Jumper Settings Jumper S...

Страница 29: ...te Definition Link left Green Solid Amber Solid 100 Mbps 1Gbps Activity Right Amber Blinking Active LAN3 LAN4 Front Panel Activity LEDs The front panel NIC Network Interface Connection activity LED in...

Страница 30: ...Windows OS Setup screen will display 3 From the Windows OS Setup screen press the Enter key The OS Setup will automatically load all device files and then continue with the Windows installation 4 Aft...

Страница 31: ...th SuperDoctor 5 Management Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors...

Страница 32: ...message will accompany it Note that BIOS has default text messages built in We retain the option to include omit or change any of these text messages Settings printed in Bold are the default values A...

Страница 33: ...ake the system unstable When this occurs revert the setting to the manufacture default settings Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the...

Страница 34: ...is feature to set the power state after a power outage Select Stay Off for the system power to remain off after a power loss Select Power On for the system power to be turned on after a power loss Sel...

Страница 35: ...verage power limit PL1 override The default setting is Disabled Power Limit 2 Override Select Enabled to support rapid power limit PL2 override The default setting is Enabled Power Limit 2 Use this it...

Страница 36: ...Code Version VT d VT d Select Enabled to enable Intel Virtualization Technology support for Direct I O VT d by reporting the I O device assignments to VMM through the DMAR ACPI Tables This feature of...

Страница 37: ...to select the scale used for the slot power limit value The options are 1 0x 0 1x 0 01x and 0 001x Program PCIe ASPM After OPROM PCIe ASPM the Active State Power Management for PCI Express slots is a...

Страница 38: ...tive State Power Management ASPM level for the PCI E device installed on the slot specified Select Auto for the system BIOS to automatically set the ASPM level based on the system configuration Select...

Страница 39: ...rity Frozen Mode The options are Enabled and Disabled SATA Port 0 Port 7 This item displays the information detected on the installed SATA drive on the particular SATA port Port 0 Port 7 The status of...

Страница 40: ...UEFI Unified Extensible Firmware Interface for network stack support The options are Enabled and Disabled IPv4 PXE Support Select Enabled to enable IPv4 PXE boot support The options are Enabled and D...

Страница 41: ...items will become available COM1 Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer which is the remote computer use...

Страница 42: ...remote computer used by the user COM2 Terminal Type Use this feature to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII Character set Select VT100 to a...

Страница 43: ...Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 576...

Страница 44: ...for both versions The default setting is Auto The following are information will be displayed TPM Enabled Status TPM Active Status TPM Owner Status TXT Support Intel TXT Trusted Execution Technology h...

Страница 45: ...he user to configure Intelligent Platform Management Interface IPMI settings The following IPMI information will be displayed IPMI Firmware Revision IPMI Status System Event Log Enabling Disabling Opt...

Страница 46: ...dress for this computer Mac addresses are 6 two digit hexadecimal numbers Router IP Address This item displays the Router IP address for this computer This should be in decimal and in dotted quad form...

Страница 47: ...natures Size Key Key Source Forbidden Signatures Size Key Key Source Authorized TimeStamps Size Key Key Source 6 7 Boot Settings This submenu allows the user to configure Boot settings for this system...

Страница 48: ...Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility a...

Страница 49: ...e BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press Enter Use this feature to retrieve user defined settings that were saved...

Страница 50: ...o continue the boot up process The error messages normally appear on the screen Fatal errors are those which will not allow the system to continue the boot up procedure If a fatal error occurs you sho...

Страница 51: ...it den Gefahren elektrischer Schaltungen und den blichen Verfahren zur Vorbeugung vor Unf llen vertraut Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen berset...

Страница 52: ...DEZE INSTRUCTIES Installation Instructions Warning Read the installation instructions before connecting the system to the power source Warnung Vor dem Anschlie en des Systems an die Stromquelle die I...

Страница 53: ...che installatie Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 250V 20A Power Disconnection Warning Warnung Das System muss von allen Quellen der Energie und vom Netzanschluss...

Страница 54: ...dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Restricted Area Waarschuw...

Страница 55: ...alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en sleutel of andere veiligheidsmaatregelen Battery Handling Warnung Bei Einsetzen einer falschen Batterie besteht Explosion...

Страница 56: ...he unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Waarschuwing Deze eenheid kan me...

Страница 57: ...enance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing Comply with Local and National Electrical Codes Warnung Die Installation...

Страница 58: ...ertencia Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales Waarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemm...

Страница 59: ...Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von...

Страница 60: ...appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bij het...

Страница 61: ...813MFTQC 350CB 1U Rackmount 17 2 x 1 7 x 20 in 437 x 43 x 508 mm W x H x D System Cooling Four 4 cm PWM fans Power Supply Model PWS 350 1H AC Input Voltages 100 240 VAC Rated Input Current 4 2A 100V t...

Отзывы: