USER’S MANUAL
Revision 1.0a
SuperServer
®
420GP-TNAR
420GP-TNAR+
Страница 1: ...USER S MANUAL Revision 1 0a SuperServer 420GP TNAR 420GP TNAR...
Страница 2: ...ass A device or in residential environment for Class B device This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the manufacturer s i...
Страница 3: ...drivers and utilities https www supermicro com wdl Product safety info http www supermicro com about policies safety_information cfm If you have any questions please contact our support team at suppor...
Страница 4: ...GPU and PCI Mapping 20 Chapter 2 Server Installation 2 1 Overview 22 2 2 Preparing for Setup 22 Choosing a Setup Location 22 Rack Precautions 22 Server Precautions 23 Rack Mounting Considerations 23...
Страница 5: ...0 Series Memory Population Table 44 DIMM Installation 45 DIMM Removal 45 3 5 Motherboard Battery 46 3 6 GPUs 47 GPU Tray 47 Switch Tray 48 Replacing GPUs 49 3 7 Storage Drives 51 Drive Carrier Indicat...
Страница 6: ...equirements and Restrictions 81 Supported SSDs and Operating Sytems 81 Additional Information 82 Hardware Key 82 Enabling NVMe RAID 83 Status Indications 86 Hot Swap Drives 86 Hot unplug 86 Hot plug 8...
Страница 7: ...the UEFI BIOS Image 95 Recovering the Main BIOS Block with a USB Device 95 7 7 CMOS Clear 100 7 8 Where to Get Replacement Components 101 7 9 Reporting an Issue 101 Technical Support Procedures 101 R...
Страница 8: ...Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl...
Страница 9: ...ays Four optional rear 2 5 NVMe drive bays requires NVMe optional kit Two NVMe SATA3 M 2 Expansion Slots Two PCIe Gen 4 x16 slots from CPUs Eight PCIe Gen 4 x16 slots from PLX One AIOM PCIe Gen 4 x16...
Страница 10: ...Figure 1 1 Front View System Features Front Feature Description 0 5 6 hot swap 2 5 Gen 4 NVMe SAS SATA drive bays hybrid logical drive numbers shown 6 9 cm fans 7 Two PCIe 4 x16 slots 8 3U GPU Node 9...
Страница 11: ...rted such as hot spare Drive Carrier LED Indicators Color Blinking Pattern Behavior for Device Activity LED Blue Solid On Idle SAS NVMe drive installed Blue Blinking I O activity Off Idle SATA drive S...
Страница 12: ...sier location of the server in a rack environment BMC Reset BMC reset button USB Two USB3 0 ports BMC LAN Dedicated BMC LAN port VGA VGA port Information LED Status Description Continuously on and red...
Страница 13: ...CPU1 5 PCIe Gen4 x16 slot internal low profile slot from PLX CPU1 6 PCIe Gen4 x16 slot internal low profile slot from PLX CPU2 7 PCIe Gen4 x16 slot internal low profile slot from PLX CPU2 8 PCIe Gen4...
Страница 14: ...gh temperature Over voltage under voltage etc OFF 1Hz Blink Amber AC present only 12vsb on PS off 1Hz Blink Green OFF Output ON and OK Green OFF AC cord unplugged and in redundant mode OFF Amber Riser...
Страница 15: ...cooling Fan Board Fan power board NVSwitch Nvidia NVSwitches Nvidia HGX A100 GPUs Graphics processing units 1 3 System Architecture This section covers the locations of the system electrical component...
Страница 16: ...Supermicro 1 CPU1 PLX 1x NVMe U 2 Delta GPU Baseboard x16 NIC NIC x16 x16 x16 x4 SWITCH NODE CPU2 x16 x16 UPI Pcie Slot Pcie Slot x16 x16 CPU NODE PCH 2x M 2 NVMe PCIe Gen4 System Block Diagram PLX PL...
Страница 17: ...P1 DIMME2 P1 DIMMH1 P1 DIMMH2 P1 DIMMG1 P1 DIMMG2 P1 DIMMC2 P1 DIMMD2 P1 DIMMC1 P1 DIMMD1 I SATA0 3 P1 DIMMA2 P1 DIMMA1 P1 DIMMB2 P1 DIMMB1 I SATA4 7 IPMI DATA CLK P2 DIMMF2 P2 DIMMF1 P2 DIMMH1 P2 DI...
Страница 18: ...ATA 3 0 Ports 0 3 6Gb sec JHDD_PWR0 JHDD_PWR1 Power connectors for hard drive backplane JIPMB1 4 pin BMC external I2 C header JM2_1 JM2_2 M 2 Slots JMB_AIOM PCIe signal to AIOM board JMB_E1 4 PCIe sig...
Страница 19: ...LEDM1 JMB_E5 JMB_E6 JUSB1 CPU1 JMB_E4 JMB_E3 JMB_E2 JMB_E1 FANB BT1 FANA USB0 3 0 VROC JRK1 BMC UM13 UM15 UM16 UM14 LED2 M 2 H2 M 2 H1 P1 DIMMF1 P1 DIMMF2 P1 DIMME1 P1 DIMME2 P1 DIMMH1 P1 DIMMH2 P1 DI...
Страница 20: ...e images and tables below for the GPU and PCI mapping for the 420GP TNAR 420GP TNAR GPU Mapping Table Linux OS Numbering PCI Bus ID BMC Number 0 27 00 5 1 2A 00 7 2 51 00 6 3 57 00 8 4 9E 00 1 5 A4 00...
Страница 21: ...Slot Mapping Table Slot Number PCI Bus ID BMC Number 1 75 00 1 2 F3 00 2 3 2D 00 3 4 30 00 4 5 5E 00 5 6 5F 00 6 7 A5 00 7 8 A8 00 8 9 D1 00 9 10 CE 00 10 11 AIOM slot 11 00 11 Figure 1 9 PCIe Slot M...
Страница 22: ...ease read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where hea...
Страница 23: ...ponents at the bottom of the rack first and then work your way up Use a regulating uninterruptible power supply UPS to protect the server from power surges and voltage spikes and to keep your system o...
Страница 24: ...d be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mou...
Страница 25: ...deline for installing the system into a rack with the rack mounting hardware provided You should also refer to the installation instructions that came with the specific rack you are using Installing t...
Страница 26: ...arrow on the rail which indicates the end that attaches to the front of the rack 4 Slide the rails sections apart to match the depth of the rack Position the rails with the template and secure the fro...
Страница 27: ...hese handles need only be installed when mounting the system into a short rack When mounting into a deep rack they are unnecessary and regular screws should be used instead of thumbscrews 2 Using a li...
Страница 28: ...Please follow the procedures given in each section 3 1 Removing Power Use the following procedure to ensure that power has been removed from the system This step is necessary when removing or installi...
Страница 29: ...crew holding the release lever and set aside The locking screw is next to the riser slot 2 Pull both release levers out 3 Press outwards slightly and pull out the tray Figure 3 1 Motherboard Tray Hand...
Страница 30: ...s engaged 4 Release the safety locks on both side of the GPU tray 5 Continue to carefully and slowly pull and remove the GPU tray from the chassis enclosure 6 Place the GPU tray on a safe surface 7 Se...
Страница 31: ...owly pull the switch tray outward from the chassis enclosure 4 Service the switch tray as needed 5 With both tray handles in fully pulled down positions carefully and slowly reinsert the switch tray b...
Страница 32: ...unplug the AC power cords from all power supplies Check that the plastic protective cover is on the CPU socket and that none of the socket pins are bent If they are contact your retailer When handling...
Страница 33: ...tic Sensitive Devices section earlier in this chapter 1 Hold the processor with the gold pins LGA lands facing down Locate the gold triangle at the corner of the processor and the corresponding hollow...
Страница 34: ...ess the other end down until it snaps into latch 2 6 After the processor is placed inside the carrier examine the four sides of the processor making sure that the processor is properly seated on the c...
Страница 35: ...orners of the heatsink as shown in the drawing below 2 Hold the processor carrier assembly upside down to locate the triangles on the processor and the carrier which indicate pin 1 3 Turn the processo...
Страница 36: ...cket for Installation The CPU socket comes with a plastic protective cover which needs to be removed before installing the Processor Heatsink Module PHM Do this by gently squeezing the grip tabs then...
Страница 37: ...fasteners a b c d on the CPU socket 2 Locate four peek nuts A B C D and four rotating wires 1 2 3 4 on the heatsink as shown below 3 Check the rotating wires 1 2 3 4 to make sure that they are in the...
Страница 38: ...ly attached to its corresponding threaded fastener 6 Press all four rotating wires outward and make sure that the heatsink is securely latched into the CPU socket 7 With a t30 bit screwdriver tighten...
Страница 39: ...power supplies 1 Use a t30 bit screwdriver to loosen the four peek nuts on the heatsink in the sequence of A B C and D 2 Once the peek nuts have been loosened from the CPU socket press the rotating w...
Страница 40: ...lease follow the steps below 1 Detach the four plastic clips marked a b c d on the processor carrier assembly from the four corners of the heatsink marked A B C D as shown below 2 When all plastic cli...
Страница 41: ...sor from the processor carrier by following the steps below 1 Unlock the lever from its locked position and push it upwards to disengage the processor from the processor carrier as shown below right L...
Страница 42: ...n Intel Xeon Scalable processors 83xx 63xx 53xx 4315 Series only 2 P1 DIMMB2 P2 DIMMB2 memory slots are reserved for Intel Optane PMem 200 Series only 3 Memory speed support depends on the processors...
Страница 43: ...DIMMC1 P1 DIMMG1 CCPU2 P2 DIMMA1 P2 DIMMB1 P2 DIMME1 P2 DIMMF1 P2 DIMMC1 P2 DIMMG1 2 CPUs 14 DIMMs CPU1 P1 DIMMA1 P1 DIMMB1 P1 DIMMD1 P1 DIMME1 P1 DIMMF1 P1 DIMMC1 P1 DIMMG1 P1 DIMMH1 CPU2 P2 DIMMA1 P...
Страница 44: ...R4 PMem DDR4 PMem DDR4 DDR4 PMem DDR4 PMem DDR4 DDR4 Two x2 DDR4 PMem DDR4 DDR4 DDR4 PMem PMem DDR4 DDR4 DDR4 PMem DDR4 One x4 DDR4 PMem DDR4 DDR4 PMem DDR4 DDR4 PMem DDR4 DDR4 PMem DDR4 8 8 AD MM One...
Страница 45: ...ush both ends of the module straight down into the slot until the module snaps into place Notches Push both ends straight down into the memory slot DIMM Removal Press both release tabs on the ends of...
Страница 46: ...the motherboard Replacing the Battery Begin by removing power from the system 1 Push aside the small clamp that covers the edge of the battery When the battery is released lift it out of the holder 2...
Страница 47: ...l the GPU tray Caution The GPU tray may weigh up to 45 lbs When moving the tray exercise caution and use multiple people Installing the GPU Tray 1 The release lever on both side must be in the fully o...
Страница 48: ...andles must be in the unlocked and extended position to install the switch tray Installing the Switch Tray 1 The handle on each side must be in the fully pulled down position 2 Slide the tray into the...
Страница 49: ...d Module 1 Run Nvidia s Field Diagnostic tool to isolate failures and obtain a log file for review 2 Disconnect the GPU baseboard module s 54V power cable 3 Remove the two GPU air shrouds Each air shr...
Страница 50: ...t Baseboard Field Diagnostics Software Guide DU 09163 001 Use these tools to determine the failed GPU and locate using the GPU Mapping Table Be sure to identify the failed GPU correctly and if any que...
Страница 51: ...rs Each drive carrier has two LED indicators an activity indicator and a status indicator In RAID configurations the status indicator lights to indicate the status of the drive In non RAID configurati...
Страница 52: ...ndle If the release button does not release it the handle may be locked using a flat head screwdriver rotate the screw counterclockwise 45 degrees to unlock the handle Figure 3 7 Unlocking Handle 2 Us...
Страница 53: ...t the drive with the connector facing the bottom rear of the carrier The drive can be inserted from above the carrier and into the clips until a click is heard 3 Use the open handle of the drive carri...
Страница 54: ...permicro servers support NVMe surprise hot swap For even better data security NVMe orderly hot swap is recommended NVMe drives can be ejected and replaced remotely using the BMC Ejecting a Drive 1 BMC...
Страница 55: ...f all NVMe drives as in the figure above BMC Server Health Sensor Reading NVME_SSD Shows the single highest temperature among all the NVMe drives Replacing the Drive 1 Insert the replacement drive 2 B...
Страница 56: ...BAR CODE PRESS FIT DESIGNED IN USA REV 1 01 X12DGO 6 FAN7 JBT1 JPWR_ RISER JMB_AIOM JTPM1 FAN8 FAN6 FAN5 FAN4 FAN3 FAN2 FAN1 JIPMB1 JHDD_PWR1 JHDD_PWR0 JSLIM4A JSLIM1B JSLIM1A JSLIM3A JSLIM4B JSLIM3B...
Страница 57: ...ndoff on the motherboard lift up its top square latch and use gentle force to pull it out of the hole 4 Move and place the standoff plug in the proper hole 5 Insert the M 2 2280 device at a slight ang...
Страница 58: ...ower down the system and remove the motherboard tray as described in Section 3 1 and 3 2 Figure 3 12 Expansion Bracket Release Tab Release Tab 2 Rotate open both release tabs until the arrows point do...
Страница 59: ...the screw Figure 3 13 Remove Shield and Screw Figure 3 14 Install Card and Screw Figure 3 15 Remove Shield Figure 3 16 Install AIOM Installing AIOM in the Switch Tray 1 Power down the system and remo...
Страница 60: ...If a fan fails the remaining fans will ramp up to full speed The system can continue to run with a failed fan in the GPU node or CPU node Replace any failed fan at your earliest convenience with the s...
Страница 61: ...Ds display system heat status See Control Panel in Chapter 1 for details Overheating There are several possible responses if the system overheats Overheat Temperature Setting Some backplanes allow the...
Страница 62: ...ng from the motherboard 5 Remove the four pin securing the fan to the fan tray 6 Lift the fan from the fan tray and out of the chassis 7 Place a new fan in the open position in the fan tray Make sure...
Страница 63: ...led 3 Gently place the air shroud over the CPU heatsinks with the front snap locations lining up with metal chassis middle crossbar Be careful that the airshroud legs at either end do not interfere wi...
Страница 64: ...0 120v or 180 240v An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Logical numbering of the power s...
Страница 65: ...the LED blinks at 2 Hz The BMC resets and the reset duration is 250 ms Then the BMC starts to boot Restore factory default configuration Hold the button for twelve seconds The LED blinks at 4 Hz while...
Страница 66: ...rboard manual Please review the Safety Precautions in Appendix A before installing or removing components 4 1 Power Connections SMCI Propietary Power Connectors Four SMCI proprietary power supply conn...
Страница 67: ...t install a VROC RAID Key on JRK1 as shown in the illustration below Intel VROC Key Pin Definitions Pin Definition 1 Ground 2 3 3V Standby 3 Ground 4 PCH RAID Key VROC Key VROC Key Header JRK1 Note Th...
Страница 68: ...or is a security device that supports encryption and authentication in hard drives It allows the motherboard to deny access if the TPM associated with the hard drive is not installed in the system For...
Страница 69: ...IPMB1 Connect the appropriate cable here to use the BMC I2 C connection on your system Refer to the table below for pin definitions External I2 C Header Pin Definitions Pin Definition 1 Data 2 Ground...
Страница 70: ...ts to JSLOT1 The dedicated BMC LAN is supported by the onboard AST 2600 BMC and accepts an RJ45 type cable Refer to the LED Indicator Section for LAN LED information Universal Serial Bus USB Ports The...
Страница 71: ...ely removed Connector Pins Jumper Setting 3 2 1 3 2 1 CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accident...
Страница 72: ...ctivity Right Amber Blinking Active UID LED LED Indicator LED Color Definition Blue On Unit Identified Unit ID LED A UID LED indicator is located at LED1 The UID indicator provides easy identification...
Страница 73: ...rmally Refer to the table below for more information M 2 LED State LED Color Definition Green Blinking Device Working BMC Heartbeat LED A BMC Heartbeat LED is located at LEDM1 When LEDM1 is blinking t...
Страница 74: ...ted by the Intel C621A chipset M 2 Slot The X12DGO 6 motherboard has two M 2 slots JM2_1 JM2_2 M 2 was formerly known as Next Generation Form Factor NGFF and serves to replace mini PCIe M 2 allows for...
Страница 75: ...supermicro com support manuals Installing the OS 1 Create a method to access the MS Windows installation ISO file That might be a DVD perhaps using an external USB SATA DVD drive or a USB flash drive...
Страница 76: ...iver browse the USB flash drive for the proper driver files For RAID choose the SATA sSATA RAID driver indicated then choose the storage drive on which you want to install it For non RAID choose the S...
Страница 77: ...Another option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or...
Страница 78: ...a email or Simple Network Management Protocol SNMP SuperDoctor 5 comes in local and remote management versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 M...
Страница 79: ...are related to BMC For general documentation and information on BMC visit our website at www supermicro com en solutions management software bmc resources BMC ADMIN User Password For security each sys...
Страница 80: ...l Parts List NVMe Option Kit Description Part Number Quantity MicroFit 2x2 36 cm GPU cable CBL PWEX 1231 1 SlimLine LP x8 to SlimLine LP x8 24 cm cable CBL SAST 1224LP 85 2 Hot swap thin profile 2 5 t...
Страница 81: ...Storage Technology enterprise Intel RSTe Driver for Linux Windows https downloadcenter intel com download 28108 Intel Virtual RAID on CPU Intel VROC and Intel Rapid Storage Technology enterprise Intel...
Страница 82: ...he key options are Intel VROC Keys VROC Package Description Part Number Intel MM Number Standard RAID 0 1 10 Supports 3rd party SSDs AOC VROCSTNMOD 951605 Premium RAID 0 1 5 10 Supports 3rd party SSDs...
Страница 83: ...h PStack based on the your model server For M 2 NVMe or NVMe AIC enable the VMD according to which AOC card slot it used Examples for some U 2 configurations follow 6 Press F4 to save the configuratio...
Страница 84: ...84 Chapter 6 Optional Components Figure 6 2 BIOS VMD Setting Examples Need new screenshots...
Страница 85: ...thout enabling RAID spanned over VMD Controller Figure 6 4 Created Volume with enabling RAID spanned over VMD Controller 13 Select Strip Size Default 64KB 14 Select Create Volume 15 If another RAID is...
Страница 86: ...evice Hot plug Physically install the device ESXi will automatically discover NVMe SSDs but a manual scan may be required in some cases Related Information Links 1 https kb vmware com s article 215140...
Страница 87: ...s manuals BIOS BMC drivers etc FAQs RMA warranty and other service extensions Direct Links for the 420GP TNAR 420GP TNAR System SYS 420GP TNAR 420GP TNAR specifications page X12DGO 6 motherboard page...
Страница 88: ...al documentation and information on BMC please visit our website at www supermicro com en solutions management software bmc resources Figure 7 2 BMC Sample SuperDoctor5 Large Deployment Guide For vali...
Страница 89: ...nnected to your power supply 4 Make sure that no short circuits exist between the motherboard and chassis 5 Disconnect all cables from the motherboard including those for the keyboard and mouse 6 Remo...
Страница 90: ...ommended that you use the same memory type and speed for all DIMMs in the system See Section 3 3 for memory details 3 Check for bad DIMM modules or slots by swapping modules between slots and noting t...
Страница 91: ...before or during OS installation check the following 1 Source of installation Make sure that the devices used for installation are working properly including boot devices such as CD 2 Cable connectio...
Страница 92: ...here is an issue with GPU detection from the switchboard 3 In this situation power down the system and reseat the GPU tray Ensure it s fully seated and locked into the chassis 4 Power the system back...
Страница 93: ...nding beep codes encountered by users BIOS Error Beep POST Codes Beep Code Error Message Description 1 short Refresh Circuits have been reset Ready to power up 5 short 1 long Memory error No memory de...
Страница 94: ...ovide information to support staff You can download a crash dump of status information using BMC Check the BMC Error Log 1 Access the BMC web interface 2 Click the Server Health tab then Event Log to...
Страница 95: ...ed When the system power is turned on the recovery block codes execute first Once this process is complete the main BIOS code will continue with system initialization and the remaining POST Power On S...
Страница 96: ...e BIOS binary image into a USB flash device and rename it Super ROM for the BIOS recovery use Note 2 Before recovering the main BIOS image confirm that the Super ROM binary image file you download is...
Страница 97: ...shown above displays use the arrow keys to select the item Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrupt...
Страница 98: ...EFI Shell prompt appears type fs to change the device directory path Go to the directory that contains the BIOS package you extracted earlier from Step 6 Enter flash nsh BIOSname at the prompt to star...
Страница 99: ...complete When you see the screen above unplug the AC power cable from the power supply clear CMOS and plug the AC power cable in the power supply again to power on the system 10 Press Del continuously...
Страница 100: ...wn the system completely 2 Remove the cover of the chassis to access the motherboard 3 Remove the onboard battery from the motherboard 4 Short the CMOS pads with a metal object such as a small screwdr...
Страница 101: ...boot block code 3 If you still cannot resolve the problem include the following information when contacting us for technical support System motherboard and chassis model numbers and PCB revision numb...
Страница 102: ...ure due to the alteration misuse abuse or improper maintenance of products During the warranty period contact your distributor first for any product problems Vendor Support Filing System For issues re...
Страница 103: ...om Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support sup...
Страница 104: ...ssistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These wa...
Страница 105: ...idere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el te...
Страница 106: ...dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het...
Страница 107: ...i n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het systeem...
Страница 108: ...del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l installa...
Страница 109: ...g a y del cable el ctrico quitado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre...
Страница 110: ...s aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Warnun...
Страница 111: ...n Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation in res...
Страница 112: ...na de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc s une...
Страница 113: ...e ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta R...
Страница 114: ...evolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All connec...
Страница 115: ...te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention C...
Страница 116: ...tencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circu...
Страница 117: ...con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden...
Страница 118: ...elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled according...
Страница 119: ...lage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving parts...
Страница 120: ...rnilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient toujo...
Страница 121: ...r CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSA Supermicro Supermicro UL CSA UL CSA Supermicro UL CSA U...
Страница 122: ...code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto utilic...
Страница 123: ...uitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing of b...
Страница 124: ...or 8TB of Intel Optane PMem 200 Series with speeds of up to 3200 MHz Storage Drives Six 2 5 hot swap NVMe SAS SATA drive bays Four optional rear 2 5 NVMe drives Two NVMe SATA3 M 2 PCI Expansion Slots...
Страница 125: ...20Vac 10 9 5A 220 230Vac 10 9 5A 230 240Vac 10 9 8A 220 240Vac 11 8 9 6A UL cUL only 230 240Vdc 10 9 8A CQC only 420GP TNAR PWS 3K02G 2R 80Plus Titanium Level Total Output Power 2880W with 200 207Vac...
Страница 126: ...BS 61000 4 5 EN BS 61000 4 6 EN BS 61000 4 8 EN BS 61000 4 11 Green Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive Product Safety 2014 35 EU LVD Directive Electric...