Chapter 1: Introduction
1.2 System Features
The following views of the system display the main features. Refer to
specifications.
Front View
Figure 1-1. Front View
Drive Carrier Indicators
Each drive carrier has two LED indicators: an activity indicator and a status indicator. For RAID
configurations using a controller, the meaning of the status indicator is described in the table
below. For OS RAID or non-RAID configurations, some LED indications are not supported,
such as hot spare. For VROC configurations, refer to the
Drive Carrier LED Indicators
Color
Blinking Pattern
Behavior for Device
Activity
LED
Blue
Solid On
Idle SAS/NVMe drive installed
Blue
Blinking
I/O activity
Off
Idle SATA drive
Status
LED
Red
Solid On
Failure of drive with RSTe support
Red
Blinking at 1 Hz
Rebuild drive with RSTe support
Red
Blinking with two blinks
and one stop at 1 Hz
Hot spare for drive with RSTe support
Red
On for five seconds,
then off
Power on for drive with RSTe support
Red
Blinking at 4 Hz
Identify drive with RSTe support
Control Panel
Chassis Front Features
Features
Descriptons
Control Panel
Power button and status indicators
Storage Drives
Three hot-swap 2.5" drive bays; the drive carriers display status lights
Latch Levers
Levers for two latches that secure the blade in the enclosure
Service/Asset
Tag
Pull-out identifier (with BMC ADMIN
)
Latch Lever
Service Tag
Latch Lever
Storage Drive
Storage Drive
Storage Drive