Chapter 7: BIOS
7-11
Sredir Memory Display Delay
Use this setting to set the delay in seconds to display memory information.
Options are
No Delay
, 1 sec, 2 secs and 4 secs.
Hardware Health Configuration
CPU Overheat Alarm
This setting allows you to specify the type of alarm for CPU overheating. Options
include The Early Alarm and
The Default Alarm
.
Fan Speed Control Modes
This feature allows the user to determine how the system will control the speed
of the onboard fans. The options are Full Speed/FS (Max Cooling), Performance/
PF (Better Cooling),
Balanced/BL
(Balance between performance and energy
saving), Energy Saving/ES (Lower Power and Noise).
Other items in the submenu are systems monitor displays for the following
information:
CPU Temperature, NB Temperature, Air Temperature, System Temperature,
Fan 1-6 Reading, CPU VCore, CPU Mem VTT, CPU Mem, 1.1V, 1.8V, 5V
+12V, -12V, 3.3 Vcc, 3.3 VSB, VBAT and HT Voltage.
CPU Temperature Display (CTD)
CPU Temperature descriptions are defined as:
Low
[Tctl Value = Lowest Value, Tctl Value = -45]
Medium
[Tctl Value = -46, Tctl Value = 60]
High
[Tctl Value = -61 and Above]
Note: Only CPU temperature (Low, Medium, High) and system temperature (RT1)
are required to be displayed in BIOS and in-system monitoring software. Other
Motherboard components such as memory, chipset, SAS and 10Gb controllers,
and others are not requried to display temperatures. For debugging and testing
purposes, BIOS and system monitoring software can show motherboard
components’ temperatures (such as memory, chipset, SAS and 10Gb controllers).
However for SMCI standard release version BIOS and system monitoring software,
motherboard components’ temperatures are NOT required to be displayed.
CPU Overheating Alarm (COA)
CPU Overheating Alarm (COA) has “
Early Alarm
” and “
Default Alarm
” (default)
options in the BIOS, and is required to be implemented in all fan speed control
modes.
Содержание A+ SERVER 1012C-MRF
Страница 1: ...SUPER A SERVER 1012C MRF USER S MANUAL Revision 1 0c...
Страница 5: ...v Preface Notes...
Страница 9: ...ix Table of Contents Appendix A BIOS Error Beep Codes Appendix BSystem Specifications...
Страница 10: ...Notes x A SERVER 1012C MRF USER S MANUAL...
Страница 16: ...1 6 A SERVER 1012C MRF USER S MANUAL Notes...
Страница 24: ...2 8 A SERVER 1012C MRF USER S MANUAL Figure 2 4 Installing the Server into a Telco Rack...
Страница 28: ...2 12 A SERVER 1012C MRF USER S MANUAL Notes...
Страница 32: ...3 4 A SERVER 1012C MRF USER S MANUAL Notes...
Страница 84: ...5 32 A SERVER 1012C MRF USER S MANUAL Notes...
Страница 90: ...6 6 A SERVER 1012C MRF USER S MANUAL Figure 6 3 Removing the DVD ROM Drive...
Страница 92: ...6 8 A SERVER 1012C MRF USER S MANUAL Notes...
Страница 110: ...7 18 A SERVER 1012C MRF USER S MANUAL Notes...
Страница 112: ...A 2 A SERVER 1012C MRF GIBXF GIQXF USER S MANUAL Notes...
Страница 115: ...B 3 Appendix C System Specifications Notes...