Chapter 5: Advanced Serverboard Setup
5-9
Figure 5-4. Populating the MEC
(Four DIMM installation shown)
4.
Installing the MEC:
After populating the MEC, carefully install it back into its slot on the
serverboard, making sure it is fully seated. Finish by securing each end
of the retention plate to the chassis with the two screws you removed
as described in step one.
Note:
Always install DIMMs from the bottom of the MEC card up and in
groups of four. If four DIMMs are to be installed, you must populate the
four DIMM slots along the bottom of the MEC (as shown in Figure 5-4). If
eight are to be installed, you must populate the eight bottom DIMM slots,
and so on.