Premier VS Infrared Heating System
Page 54
June 04, 2014
INSTALLATION –
Part 5
General Requirements (cont’d)
A
- Burners
Maximum current draw is 0.2 A per Burner. Burners operate on 120 VAC, 60 Hz. Internal Burner wiring
between the transformer, gas valve, etc. has been completed by the manufacturer as shown in Figure 40 and
Figure 41 and in the Wiring Diagram located on the inside of the panel door on the Burner Cover. Burners are
connected via a standard three-prong plug (grounded) which has a Power Cord length of 3 ft (90 cm) and
extends from the back of the Burner.
Any repair / replacement of the manufacturer’s wiring must have a minimum temperature rating of
at least
105
C
and supply circuit wiring shall have a
minimum size of 18 AWG.