INSTALLATION –
Part 1
C
- Burners
Each Burner in a Premier VS Branch must be placed in its appropriate position,
and have the appropriate Air Plate installed.
Burner Position No.1 is at the furthest end of the branch from the Vacuum Pump and the
Burner number increases as the branch runs towards the Vacuum Pump.
(As shown in
Figure 16
& referred to in your System Design Layout)
Each Burner is shipped with a Burner Rating Plate & As-Built Burner Position Label affixed,
with the corresponding Air Plate installed. If the System Design Layout changes and the
Burner must be placed in a position other than the As-Built Burner Position then the Air Plate
will need to be replaced with the appropriate one for the required new Position.
(See below figure for details.)
Verify that the Burners are correct for the fuel being burned.
Figure 16 : Burner Position Reference Diagram