When a heater is to be mounted outdoors it must be installed in such a way that wind will have minimum
effect on its movement. This consideration is intended to eliminate undue stress on the gas flex connector.
In all cases a fresh air hood must be used in conjunction with a vent terminal of the approved type, and all
connections must be sealed with a high temperature sealant that can withstand 400°F.
Figure 31: Outdoor Installation
Note: that this heater is a sealed construction. If any services or repair is conducted in the future,
gasket materials should be inspected and replaced if found to be deteriorated.
Outdoor Installation
Fresh Air
Inlet Hood
Seal Joints
Vent Terminal
Seal Joints