www.SuperiorFireplaces.US.com
127042-01A
12
INSTALLATION
Continued
Figure 17 - Placement of Embers
PLACEMENT OF LOOSE EMBERS
CAUTION: Do not place
any loose embers around pilot
assembly.
Two bags of loose embers are provided with
this unit. For this installation use the embers
that are approximately 1" square in size. If
needed, larger embers can be broken to size.
These embers aid in concealing the burner
pan, directing flames through the ember bed,
quiet operation of the unit and gives a natural
random flame pattern.
Place embers as follows:
1. Place embers around center ember bed
or ember pod.
2. Place individual embers on their edge (not
flat) along the top of burner pan. This aids
in directing flames from the burner through
ember bed.
Note: Too many embers or embers placed
flat along burner pan can suppress the
flames.
3. When unit is lit, check flames for random
appearance and ember bed glowing red-
orange in color (see
Burner Flame Pattern
,
page 17). If this is not happening, either
add, remove or reposition loose embers.
IMPORTANT:
Turn unit off and let cool
before repositioning loose embers.
Figure 16 - Checking Gas Joints
(Natural Gas Only)
Control Valve
Location
Equipment
Shutoff Valve
Propane/LP
Supply Tank
Equipment
Shutoff Valve
Gas Meter
Figure 15 - Checking Gas Joints
(Propane/LP Gas Only)
Control Valve
Location
Pressure Testing Appliance Gas
Connections
1. Open equipment shutoff valve (see Figure
14, page 10).
2. Open main gas valve located on or near
gas meter for natural gas or open pro
-
pane/LP supply tank valve.
3. Make sure control knob of appliance is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas control (see Figure 15 or 16).
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light appliance (see
Operation
, page 12)
Check all other internal joints for leaks.
7. Turn off appliance.