www.SuperiorFireplaces.US.com
127042-01A
15
CLEANING AND MAINTENANCE
WARNING: Turn off the ap
-
pliance and allow to cool before
cleaning.
CAUTION: You must keep
control areas, burners and cir
-
culating air passageways of
fireplace clean. Inspect these
areas of fireplace before each
use. Have fireplace inspected
yearly by a qualified service per
-
son. Fireplace may need more
frequent cleaning due to exces
-
sive lint from carpeting, bedding
material, etc.
Only limited cleaning will be required under
normal use of this appliance. Dust the front
grate and top of receiver/valve. Do not use
cleaning fluids to clean logs or any other part
of the appliance.
If, after a period of use, the flames start to
exhibit unusual shapes and behavior or the
burner fails to ignite smoothly, then the burner
holes may require some cleaning. If this hap
-
pens, we recommend that you contact your
nearest authorized service technician to get
the appliance serviced.
• Keep area around log set clean and clear
of debris.
• Periodically inspect the air mixer and burner
tube for foreign matter blocking the air inlet
and flame holes.
HIGH ALTITUDE INSTALLATION
When the fireplace is installed at an elevation
above 2000 feet, you may need to decrease
the input rating by changing the existing
burner orifice to a smaller size. Reduce input
4% for every 1000 feet above 2000 feet which
they are installed. Check with your local gas
company for proper orifice size identification.
OPTIONAL HAND-HELD
REMOTE CONTROL
ACCESSORIES - MRC
Figure 20 - Disconnecting Jumper Wires
From Control Valve
Figure 21 - Attaching Batteries to
Receiver
REMOT
E
N
O
FF
O
LEAR
N
ADJ.
Requires 4-AA 1.5V
alkaline batteries
Learning
button
Frequency
adjusting
access hole
Remote Receiver
Batt
ery c
over
slide
s on
/off
Slide
Switch
ON
REMOTE
OFF
NOTICE: Use only alkaline bat
-
teries (included with MRC).
Installing Receiver
1. Disconnect jumper wires from the control
valve (see Figure 20).
2. Locate the battery cover on the back of
the receiver (see Figure 21).
3. Install 4-AA batteries (included) into re
-
ceiver before installing into fireplace.
4. Connect wires from remote receiver to
control valve. See instructions provided
with remote control kit for further informa
-
tion.