background image

31

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900223-00, Rev. B  10/2016

Innovative Hearth Products
150

8

 Elm Hill Pike, Suite 10

8

 • Nashville, TN 37210

Innovative Hearth Products

Superior

®

 Brand Gas Fireplaces, Stoves and Inserts

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior

®

 Brand gas fi replace, Stove or Insert ("Product") to be free from defects in materials 

and workmanship at the time of manufacture. The product body, fi rebox and barrier carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty 
against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 Year 
Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or 
replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also 
pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND 
LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of purchase. In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six 
months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following 
the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 
provided. The product body, fi rebox and barrier carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components and paint are excluded 
from this 20 Year Limited Warranty. The following do not carry the 20 Year Limited Warranty but are warranted as follows:

Burner

 – Repair or replacement for one year from the date of installation

Gas components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Logs

 – Replacement for one year from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Tempered glass

 - Replacement for one year from the date of installation

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or 
unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 
natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 
and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 
(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-
tions which may generate negative pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for drafting conditions caused by 
venting confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction, which are not 
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 
any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from the nearest stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or 
after repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a 
particular use or purpose, and there is no implied condition of fi tness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.

No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 
Limited Warranty are in addition to and not a modifi cation of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefi ts and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without fi rst obtaining IHP's prior written consent.

 

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 
IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Содержание VCI3032ZMN

Страница 1: ...ir must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious inju...

Страница 2: ...e replaced prior to operating fireplace insert system Safety 2 Local Codes 4 Commonwealth of Massachusetts Requirements 4 Unpacking 4 Product Identification 5 Remote Control Accessories 5 Product Feat...

Страница 3: ...shut off gas supply do not try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the ga...

Страница 4: ...to logs log base assembly and fireplace insert 4 Remove fireplace insert hood from carton insert 5 Check all items for any shipping damage If damaged promptly inform dealer where you purchased your fi...

Страница 5: ...g It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by both realistic flames and glowing embers When used without the blower the fireplace insert requir...

Страница 6: ...om Outdoors Page 7 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow for Heater Location Confined and Unconfined Space The National Fuel Gas Code ANSI Z2...

Страница 7: ...pplicablelocalcodes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide...

Страница 8: ...he fireplace insert is level If fireplace insert is not level log set will not work properly CHECK GAS TYPE Use the correct gas type natural or propane LP for your unit If your gas supply is not corre...

Страница 9: ...Firmly tighten all screws installed during as sembly CAUTION Do not overtighten Metal can bend warp or break under excessive strain 5 Install trim after final finishing and or painting of wall INSTALL...

Страница 10: ...ing and adjoining wall Carefully follow instructions below This will ensure safe installation Minimum Clearances For Side Combustible Material Side Wall and Ceiling A Clearancesfromsideoffireplacecabi...

Страница 11: ...w black iron or steel pipe Internally tinned copper tubing may be used in cer tain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace insert If pi...

Страница 12: ...9 Page 13 Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once INSTALLATION Continued CONNECTING FIREPLACE INSERT TO GAS SUPPLY Installation...

Страница 13: ...re 20 for masonry fireplace open ing 2 Install and properly ground GA3555 three prong 120 volt electrical outlet in fireplace insert Follow instructions included in kit see Accessories Page 28 3 Insta...

Страница 14: ...s attached to the heater base assembly These markings contain important warranty and safety information WARNING Failure to position the parts in accor dancewiththesediagramsorfailuretouseonlyparts spe...

Страница 15: ...HAND HELD REMOTE CONTROL ACCESSORIES RCKIT4001 AND TRC Installing Remote Receiver Unit 1 Disconnect switch wires from control valve 2 Remove screws attaching switch plate 3 Remove switch plate see Fig...

Страница 16: ...tically within one minute when the remote selector switch is in the ON position after the pilot is lit 4 Press in and turn control knob clockwise to the OFF position 5 Wait five 5 minutes to clear out...

Страница 17: ...Figure 30 NOTE The burner may light if hand held remote was on when selector switch was last turned off You can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave se...

Страница 18: ...All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or rust with no flame present If so turn off heater and let cool Remov...

Страница 19: ...e about 2 from where pilot flame comes out of pilot assembly see Figure 36 With unit off lightly blow air through air inlet hole You may blow through a drinking straw if compressed air is not availabl...

Страница 20: ...clogged ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect igniter cable 2 Free igniter cable if pinched by any metal or tub...

Страница 21: ...burner orifice 1 Clean burner see Cleaning and Mainte nance Page 18 or replace burner orifice 2 Replace damaged burner 3 Replace gas control 1 Check burner for dirt and debris If found clean burner se...

Страница 22: ...r 2 Gas leak See Warning statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked REMEDY 1 Open...

Страница 23: ...allation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your appliance ready You can...

Страница 24: ...13 25 15 16 21 11 10 19 20 19 23 24 22 18 1B 1A 1C 27 4 NOTE Items 27 and 28 are for natural gas only CAT NO MODEL F1790 VCI3032ZMN F2055 VCI3032ZMP WARNING Failure to position the parts in accordance...

Страница 25: ...M 1 J3607 INJECTOR 0670 1 70MM 1 8 J3763 BURNER DUAL 24 2 9 J1958 SCREW HWH AB 8 18 X 38 2 10 J3857 ASM CARRIAGE BURNER WELDED 1 11 J1961 SCREW HX SLT WSR 10 32X3 8 4 12 FIREBOX BOTTOM 1 13 J3795 WIRE...

Страница 26: ...m 127119 01C 26 11 14 8 8 14 9 3 14 9 9 2 1 7 10 14 12 5 14 13 28 15 23 4 27 6 17 16 18 19 20 21 22 22 23 14 24 25 14 26 PARTS FIREPLACE INSERT MODELS VCI3032ZMN AND VCI3032ZMP CAT NO MODEL F1790 VCI3...

Страница 27: ...HOOD FIREBOX 1 8 FIREBOX SUPPORT 2 9 J3629 SCREW HWH SHLDR AB 10 X 63 4 10 FIREBOX TOP 1 11 OUTER BASE 1 12 FIREBOX WRAPPER 1 13 J3721 COVER PAINTED 1 14 J1955 SCREW HWH AB 10 16 X 38 46 15 J3923 ASS...

Страница 28: ...or thermostatically controlled mode You can turn the gas log heater on and off without ever leaving the comfort of your easy chair A wall mount docking station is included F TEMP SET ON ROOM OFF MODE...

Страница 29: ...be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected Includes thermostat assembly 25 of wire and two mounting screws WALL MOUNT ON OF...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Страница 32: ...liance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loca...