SuperiorFireplaces.us.com
127119-01C
17
OPERATION
Continued
TO TURN OFF GAS
TO APPLIANCE
1. Turn control knob clockwise
to the OFF position.
2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set remote selector switch
in the OFF position to keep from draining battery.
3. Close equipment shutoff valve
(see
Figure 17, Page 13
).
MANUAL LIGHTING
PROCEDURE
1. Follow steps 1 through 6 under Lighting Instructions,
Page 16
.
2. Press control knob and light pilot with match.
3. Keep control knob pressed in for 30 seconds after lighting pilot.
After 30 seconds, release control knob. Now follow steps 9
through 11 under Lighting Instructions,
Page 16
.
OPTIONAL HAND-HELD
REMOTE OPERATION
NOTE:
All remote control accessories must be purchased separately
(see Accessories,
Page 28
).
Follow instructions included with the
remote control.
NOTICE: You must light the pilot before using the
hand-held remote control unit. See Lighting Instruc-
tions on
Page 16
.
After lighting, let pilot fl ame burn for about one minute. Turn control
knob to ON position. Adjust fl ame adjustment knob anywhere between
HI and LO. Slide selector switch to REMOTE position
(see
Figure 30
).
NOTE:
The burner may light if hand-held remote was on when selector
switch was last turned off. You can now turn burner on and off with
hand-held remote control unit.
IMPORTANT:
Do not leave selector switch in the REMOTE or ON
position when pilot is not lit. This will drain battery.
BLOWER
OPERATION
Locate blower switch by opening lower louver on fi replace insert.
Blower switch is located at lower left inside louver door.
This thermostat-controlled blower has three settings: ON, OFF and
AUTO. In the ON position, blower will operate constantly. In the
OFF position, blower will not operate. In the AUTO position, blower
will start when thermostat senses a suffi cient increase in fi rebox
temperature.
NOTE:
Your gas logs and thermostat blower will not turn on and off
at the same time. The fi replace insert may run for several minutes
before blower turns on. After heater modulates to pilot position,
blower will continue to run. Blower will shut off after fi rebox tem-
perature decreases.
NOTE:
It is safe to operate fi replace insert with blower turned off.
However, blower helps distribute heated air from fi replace insert.
Figure 30 - Setting the Remote Selector Switch, Control Knob
and Flame Adjustment Knob for Remote Operation
Flame Adjustment
Knob
Remote Selector Switch in
Remote Position (Optional
Hand-Held Remote Control)
Control Knob in
On Position