Superior Fireplaces VCI3032ZMN Скачать руководство пользователя страница 17

SuperiorFireplaces.us.com

127119-01C

17

OPERATION 

Continued

TO TURN OFF GAS

TO APPLIANCE

1.  Turn control knob clockwise 

 to the OFF position.

2a. Set selector switch in the OFF position.
2b. If Using Optional Hand-Held Remote: Set remote selector switch 

in the OFF position to keep from draining battery.

3.  Close equipment shutoff valve 

(see 

Figure 17, Page 13

).

MANUAL LIGHTING

PROCEDURE

1.  Follow steps 1 through 6 under Lighting Instructions, 

Page 16

.

2.  Press control knob and light pilot with match.
3.  Keep control knob pressed in for 30 seconds after lighting pilot. 

After 30 seconds, release control knob. Now follow steps 9 
through 11 under Lighting Instructions, 

Page 16

.

OPTIONAL HAND-HELD

REMOTE OPERATION

NOTE:

 All remote control accessories must be purchased separately 

(see Accessories,

 Page 28

).

 Follow instructions included with the 

remote control.

NOTICE: You must light the pilot before using the 
hand-held remote control unit. See Lighting Instruc-
tions on 

Page 16

.

After lighting, let pilot fl ame burn for about one minute. Turn control 
knob to ON position. Adjust fl ame adjustment knob anywhere between 
HI and LO. Slide selector switch to REMOTE position 

(see 

Figure 30

). 

NOTE:

 The burner may light if hand-held remote was on when selector 

switch was last turned off. You can now turn burner on and off with 
hand-held remote control unit.

IMPORTANT:

 Do not leave selector switch in the REMOTE or ON 

position when pilot is not lit. This will drain battery.

BLOWER

OPERATION

Locate blower switch by opening lower louver on fi replace insert. 
Blower switch is located at lower left inside louver door. 
This thermostat-controlled blower has three settings: ON, OFF and 
AUTO. In the ON position, blower will operate constantly. In the 
OFF position, blower will not operate. In the AUTO position, blower 
will start when thermostat senses a suffi cient increase in fi rebox 
temperature.

NOTE:

 Your gas logs and thermostat blower will not turn on and off 

at the same time. The fi replace insert may run for several minutes 
before blower turns on. After heater modulates to pilot position, 
blower will continue to run. Blower will shut off after fi rebox tem-
perature decreases.

NOTE:

 It is safe to operate fi replace insert with blower turned off. 

However, blower helps distribute heated air from fi replace insert.

Figure 30 - Setting the Remote Selector Switch, Control Knob 

and Flame Adjustment Knob for Remote Operation 

Flame Adjustment 

Knob 

Remote Selector Switch in 
Remote Position (Optional 
Hand-Held Remote Control) 

Control Knob in 
On Position 

Содержание VCI3032ZMN

Страница 1: ...ir must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious inju...

Страница 2: ...e replaced prior to operating fireplace insert system Safety 2 Local Codes 4 Commonwealth of Massachusetts Requirements 4 Unpacking 4 Product Identification 5 Remote Control Accessories 5 Product Feat...

Страница 3: ...shut off gas supply do not try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the ga...

Страница 4: ...to logs log base assembly and fireplace insert 4 Remove fireplace insert hood from carton insert 5 Check all items for any shipping damage If damaged promptly inform dealer where you purchased your fi...

Страница 5: ...g It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by both realistic flames and glowing embers When used without the blower the fireplace insert requir...

Страница 6: ...om Outdoors Page 7 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow for Heater Location Confined and Unconfined Space The National Fuel Gas Code ANSI Z2...

Страница 7: ...pplicablelocalcodes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide...

Страница 8: ...he fireplace insert is level If fireplace insert is not level log set will not work properly CHECK GAS TYPE Use the correct gas type natural or propane LP for your unit If your gas supply is not corre...

Страница 9: ...Firmly tighten all screws installed during as sembly CAUTION Do not overtighten Metal can bend warp or break under excessive strain 5 Install trim after final finishing and or painting of wall INSTALL...

Страница 10: ...ing and adjoining wall Carefully follow instructions below This will ensure safe installation Minimum Clearances For Side Combustible Material Side Wall and Ceiling A Clearancesfromsideoffireplacecabi...

Страница 11: ...w black iron or steel pipe Internally tinned copper tubing may be used in cer tain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace insert If pi...

Страница 12: ...9 Page 13 Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once INSTALLATION Continued CONNECTING FIREPLACE INSERT TO GAS SUPPLY Installation...

Страница 13: ...re 20 for masonry fireplace open ing 2 Install and properly ground GA3555 three prong 120 volt electrical outlet in fireplace insert Follow instructions included in kit see Accessories Page 28 3 Insta...

Страница 14: ...s attached to the heater base assembly These markings contain important warranty and safety information WARNING Failure to position the parts in accor dancewiththesediagramsorfailuretouseonlyparts spe...

Страница 15: ...HAND HELD REMOTE CONTROL ACCESSORIES RCKIT4001 AND TRC Installing Remote Receiver Unit 1 Disconnect switch wires from control valve 2 Remove screws attaching switch plate 3 Remove switch plate see Fig...

Страница 16: ...tically within one minute when the remote selector switch is in the ON position after the pilot is lit 4 Press in and turn control knob clockwise to the OFF position 5 Wait five 5 minutes to clear out...

Страница 17: ...Figure 30 NOTE The burner may light if hand held remote was on when selector switch was last turned off You can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave se...

Страница 18: ...All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or rust with no flame present If so turn off heater and let cool Remov...

Страница 19: ...e about 2 from where pilot flame comes out of pilot assembly see Figure 36 With unit off lightly blow air through air inlet hole You may blow through a drinking straw if compressed air is not availabl...

Страница 20: ...clogged ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect igniter cable 2 Free igniter cable if pinched by any metal or tub...

Страница 21: ...burner orifice 1 Clean burner see Cleaning and Mainte nance Page 18 or replace burner orifice 2 Replace damaged burner 3 Replace gas control 1 Check burner for dirt and debris If found clean burner se...

Страница 22: ...r 2 Gas leak See Warning statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked REMEDY 1 Open...

Страница 23: ...allation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your appliance ready You can...

Страница 24: ...13 25 15 16 21 11 10 19 20 19 23 24 22 18 1B 1A 1C 27 4 NOTE Items 27 and 28 are for natural gas only CAT NO MODEL F1790 VCI3032ZMN F2055 VCI3032ZMP WARNING Failure to position the parts in accordance...

Страница 25: ...M 1 J3607 INJECTOR 0670 1 70MM 1 8 J3763 BURNER DUAL 24 2 9 J1958 SCREW HWH AB 8 18 X 38 2 10 J3857 ASM CARRIAGE BURNER WELDED 1 11 J1961 SCREW HX SLT WSR 10 32X3 8 4 12 FIREBOX BOTTOM 1 13 J3795 WIRE...

Страница 26: ...m 127119 01C 26 11 14 8 8 14 9 3 14 9 9 2 1 7 10 14 12 5 14 13 28 15 23 4 27 6 17 16 18 19 20 21 22 22 23 14 24 25 14 26 PARTS FIREPLACE INSERT MODELS VCI3032ZMN AND VCI3032ZMP CAT NO MODEL F1790 VCI3...

Страница 27: ...HOOD FIREBOX 1 8 FIREBOX SUPPORT 2 9 J3629 SCREW HWH SHLDR AB 10 X 63 4 10 FIREBOX TOP 1 11 OUTER BASE 1 12 FIREBOX WRAPPER 1 13 J3721 COVER PAINTED 1 14 J1955 SCREW HWH AB 10 16 X 38 46 15 J3923 ASS...

Страница 28: ...or thermostatically controlled mode You can turn the gas log heater on and off without ever leaving the comfort of your easy chair A wall mount docking station is included F TEMP SET ON ROOM OFF MODE...

Страница 29: ...be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected Includes thermostat assembly 25 of wire and two mounting screws WALL MOUNT ON OF...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Страница 32: ...liance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loca...