background image

SuperiorFireplaces.us.com

127119-01C

3

 WARNING: Do not use a blow er insert, heat ex-

 chang er insert or other accessory not ap proved for 
use with this fi replace.

  WARNING: Do not allow fans to blow directly into 

the fi replace insert. Avoid any drafts that alter burner 
fl ame patterns. Ceiling fans can create drafts that 
alter burner fl ame patterns. Altered burner patterns 
can cause sooting.

  WARNING: Any outside air ducts and/or ash dumps 

in the fi replace must be permanently closed before 
installing fi replace insert.

  WARNING: A Before installing in a solid fuel burn-

ing fi replace, the chimney fl ue and fi replace must be 
cleaned of soot, creosote, ashes and loose paint by 
a qualifi ed chimney cleaner.

 Due to high temperatures, the stove should be located 
out of traffi c and away from furniture and draperies.

Do not place clothing or other fl ammable material 
on or near the stove. Never place any objects on the 
appliance.

Fireplace insert front and screen become very hot when 
running fi replace insert.Children and adults should 
be alerted to the hazard of high surface temperature 
and should stay away to avoid burns or clothing igni-
tion.. Fireplace insert will remain hot for a time after 
shutdown. Allow surfaces to cool before touching.

SAFETY 

Continued

WARNING: Do not place  volcanic stone on burner.

Young children should be carefully supervised when 
they are in the same room with the appliance. When 
using the hand-held remote accessory, keep selector 
switch in the OFF position to prevent children from 
turning on burners with remote.

You must operate this fi replace insert with the fi replace 
insert screen and hood in place. Make sure fi replace 
insert screen and hood are in place before running 
fi replace insert.

Keep the appliance area clear and free from combus-
tible materials, gasoline and other fl ammable vapors 
and liquids.

2.  Do not place propane/LP supply tank(s) inside any structure. 

Locate propane/LP supply tank(s) outdoors (propane/LP units 
only).

3.  If you smell gas

• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use any phone in your 

building

• immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier's instructions

• if you cannot reach you gas supplier, call the fi re department.

4.  This fi replace insert shall not be installed in a bedroom or bath-

room.

5.  Do not use this fi replace insert as a wood-burning fi replace. Use 

only logs provided with fi replace insert.

6.  Do not add extra logs or ornaments such as pine cones, vermiculite 

or glowing embers (rockwool). Using these added items can cause 
sooting. Do not add volcanic stone around base. Volcanic stone 
and debris could fall into control area of fi replace insert.

7.  This fi replace insert is designed to be smokeless. If logs ever 

appear to smoke, turn off fi replace insert and call a qualifi ed 
service person.

NOTE:

 During initial operation, slight smoking could occur due 

to log curing and burning of manufacturing residues.

8.  To prevent creation of soot, follow the instructions in Cleaning 

and Maintenance, 

Page 18

.

9.  Before using furniture polish, wax, carpet cleaner or similar prod-

ucts, turn heater off. If heated, vapors from these products may 
create a white powder residue within burner box or on adjacent 
walls or furniture.

10. This fi replace insert needs fresh air ventilation to run properly. 

This fi replace insert has an Oxygen Depletion Sensing (ODS) 
safety shutoff system. The ODS shuts down the fi replace insert 
if not enough fresh air is available. See Air for Combustion and 
Ventilation, 

Page 6

. If fi replace insert keeps shutting off, see 

Troubleshooting, 

Page 20

.

Installation and repair should be done by a qualifi ed 
service person. The appliance should be inspected be-
fore use and at least annually by a professional service 
person. More frequent cleaning may be required due to 
excessive lint from carpeting, bedding material, etc. 
It is imperative that control compartments, burners, 
and circulating air passageways of the appliance be 
kept clean.

1. WARNING: This appliance is only for use with the 

type of gas indicated on the rating plate. This ap-
pliance is not convertible for use with other gases. 

Содержание VCI3032ZMN

Страница 1: ...ir must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious inju...

Страница 2: ...e replaced prior to operating fireplace insert system Safety 2 Local Codes 4 Commonwealth of Massachusetts Requirements 4 Unpacking 4 Product Identification 5 Remote Control Accessories 5 Product Feat...

Страница 3: ...shut off gas supply do not try to light any appliance do not touch any electrical switch do not use any phone in your building immediately call your gas supplier from a neighbor s phone Follow the ga...

Страница 4: ...to logs log base assembly and fireplace insert 4 Remove fireplace insert hood from carton insert 5 Check all items for any shipping damage If damaged promptly inform dealer where you purchased your fi...

Страница 5: ...g It requires no outside venting There is no heat loss out a vent or up a chimney Heat is generated by both realistic flames and glowing embers When used without the blower the fireplace insert requir...

Страница 6: ...om Outdoors Page 7 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow for Heater Location Confined and Unconfined Space The National Fuel Gas Code ANSI Z2...

Страница 7: ...pplicablelocalcodes VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide...

Страница 8: ...he fireplace insert is level If fireplace insert is not level log set will not work properly CHECK GAS TYPE Use the correct gas type natural or propane LP for your unit If your gas supply is not corre...

Страница 9: ...Firmly tighten all screws installed during as sembly CAUTION Do not overtighten Metal can bend warp or break under excessive strain 5 Install trim after final finishing and or painting of wall INSTALL...

Страница 10: ...ing and adjoining wall Carefully follow instructions below This will ensure safe installation Minimum Clearances For Side Combustible Material Side Wall and Ceiling A Clearancesfromsideoffireplacecabi...

Страница 11: ...w black iron or steel pipe Internally tinned copper tubing may be used in cer tain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume to fireplace insert If pi...

Страница 12: ...9 Page 13 Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once INSTALLATION Continued CONNECTING FIREPLACE INSERT TO GAS SUPPLY Installation...

Страница 13: ...re 20 for masonry fireplace open ing 2 Install and properly ground GA3555 three prong 120 volt electrical outlet in fireplace insert Follow instructions included in kit see Accessories Page 28 3 Insta...

Страница 14: ...s attached to the heater base assembly These markings contain important warranty and safety information WARNING Failure to position the parts in accor dancewiththesediagramsorfailuretouseonlyparts spe...

Страница 15: ...HAND HELD REMOTE CONTROL ACCESSORIES RCKIT4001 AND TRC Installing Remote Receiver Unit 1 Disconnect switch wires from control valve 2 Remove screws attaching switch plate 3 Remove switch plate see Fig...

Страница 16: ...tically within one minute when the remote selector switch is in the ON position after the pilot is lit 4 Press in and turn control knob clockwise to the OFF position 5 Wait five 5 minutes to clear out...

Страница 17: ...Figure 30 NOTE The burner may light if hand held remote was on when selector switch was last turned off You can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave se...

Страница 18: ...All round burner flame holes should be open with a small blue flame present Some burner flame holes may become blocked by debris or rust with no flame present If so turn off heater and let cool Remov...

Страница 19: ...e about 2 from where pilot flame comes out of pilot assembly see Figure 36 With unit off lightly blow air through air inlet hole You may blow through a drinking straw if compressed air is not availabl...

Страница 20: ...clogged ODS pilot 5 Thermocouple connection loose at con trol valve 6 Thermocouple damaged 7 Control valve damaged REMEDY 1 Reconnect igniter cable 2 Free igniter cable if pinched by any metal or tub...

Страница 21: ...burner orifice 1 Clean burner see Cleaning and Mainte nance Page 18 or replace burner orifice 2 Replace damaged burner 3 Replace gas control 1 Check burner for dirt and debris If found clean burner se...

Страница 22: ...r 2 Gas leak See Warning statement above 1 Improper log placement 2 Drafts or other air currents affecting flame pattern 3 Air holes at burner inlet blocked 4 Burner flame holes blocked REMEDY 1 Open...

Страница 23: ...allation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your appliance ready You can...

Страница 24: ...13 25 15 16 21 11 10 19 20 19 23 24 22 18 1B 1A 1C 27 4 NOTE Items 27 and 28 are for natural gas only CAT NO MODEL F1790 VCI3032ZMN F2055 VCI3032ZMP WARNING Failure to position the parts in accordance...

Страница 25: ...M 1 J3607 INJECTOR 0670 1 70MM 1 8 J3763 BURNER DUAL 24 2 9 J1958 SCREW HWH AB 8 18 X 38 2 10 J3857 ASM CARRIAGE BURNER WELDED 1 11 J1961 SCREW HX SLT WSR 10 32X3 8 4 12 FIREBOX BOTTOM 1 13 J3795 WIRE...

Страница 26: ...m 127119 01C 26 11 14 8 8 14 9 3 14 9 9 2 1 7 10 14 12 5 14 13 28 15 23 4 27 6 17 16 18 19 20 21 22 22 23 14 24 25 14 26 PARTS FIREPLACE INSERT MODELS VCI3032ZMN AND VCI3032ZMP CAT NO MODEL F1790 VCI3...

Страница 27: ...HOOD FIREBOX 1 8 FIREBOX SUPPORT 2 9 J3629 SCREW HWH SHLDR AB 10 X 63 4 10 FIREBOX TOP 1 11 OUTER BASE 1 12 FIREBOX WRAPPER 1 13 J3721 COVER PAINTED 1 14 J1955 SCREW HWH AB 10 16 X 38 46 15 J3923 ASS...

Страница 28: ...or thermostatically controlled mode You can turn the gas log heater on and off without ever leaving the comfort of your easy chair A wall mount docking station is included F TEMP SET ON ROOM OFF MODE...

Страница 29: ...be selected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected Includes thermostat assembly 25 of wire and two mounting screws WALL MOUNT ON OF...

Страница 30: ...__________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Страница 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a re hazard c...

Страница 32: ...liance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loca...