Operation
900636-01, 01/2017
Innovative Hearth Products
DRT4200 Series Direct-Vent Gas Fireplaces
52
Burn-in Period
The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the
lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few
days.
NOTE:
Ventilate the site during the burn-in period. The resulting odor and haze may set off a smoke detector. Do not
operate the blower during the burn-in period.
A white film may develop on the glass front during the first few fires as part of the burn-in period. The glass
should be kept clean during the burn-in period to prevent the film from baking on—making it very difficult to
remove (
Cleaning the glass door on
Page 58
)
.
Accessing the Control Compartment
Opening the Control Compartment Door
1.
Grasp the top of the control compartment door and gently pull it to release the door from the magnet. Lower the
door until it stops
(see
Figure 38
)
.
Closing the Control Compartment Door
1.
Swing the control compartment door gently up until the magnet engages the door in the closed position.
Removing the Control Compartment Door
1.
Open the lower control compartment door
(see instructions above).
2.
Remove the control compartment door by sliding the hinge pin, located at the door’s left side, to the right until it
disengages from the left corner post hole. Pull the door diagonally to the left, away from the fireplace
(see
Figure 38
)
.
Figure 38 - Control compartment door
Figure 39 - Control compartment door tabs
Electronic Fireplaces
Detailed lighting instructions are found on
Page 62
. Also, electronic fireplace lighting instructions are found on the
pull-out lighting instructions attached to the gas control valve.
If the electronic fireplace is equipped with an remote wall switch or remote control, the fireplace main burner can be
turned ON/OFF with the wall switch or remote control.
To light the fireplace in a power outage:
1.
Confirm that batteries are installed in the Wall Switch
2.
Set the unit-mounted switch, or wall switch to the ON Position.
3.
The unit should spark at the pilot and light.
NOTE:
If there is no spark, replace the batteries.
4.
Operate the fireplace normally.
Control Compartment
Access Door
Magnet
Control
Compartment
Hinge Pin