Installation
900636-01, 01/2017
Innovative Hearth Products
DRT4200 Series Direct-Vent Gas Fireplaces
38
Green
Ground
Screw
Red
Black
Hot Side of
Receptacle
Tab Intact
Tab
Intact
Green
White
Neutral
Side of
Receptacle
120 VAC - Black
Neutral - White
Ground - Green
J-BOX / RECEPTACLE
WIRING 120V, 60HZ, 1PH
Junction Box
Field Wired
Factory Wired
(Power
Supply
Unswitched)
4.
Connect the black power supply wire to the lower
outlet’s black and red pigtail lead
(
Figures 30
and
31
)
. Connect the white power supply wire to the
outlet’s common terminal.
5.
Connect the ground supply wire to the pigtail lead
attached to the outlet’s green ground screw. Restrain
the inlet power lead per NEC or local codes.
6.
After the wiring is complete, replace the cover plate.
WARNING
Electronic models of these appliances are equipped with a three-prong (grounding)
plug utilized in connecting the electronic components to the junction box in the lower
compartment. This grounding plug provides protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. DO NOT cut or remove the
grounding prong from the plug.
Figure 30 - Wiring Diagram—Junction Box