EN
EN
94
95
Lead-acid Battery Control Voltage Parameters
The parameters are in 12V system at 25 0C, please double the values in 24V system.
Lithium Battery Control Voltage Parameters
The parameters are in 12V system at 25 0C, please double the values in 24V system.
Battery type Voltage parameter
Sealed
Gel
Flooded
User
Over Voltage Disconnect Voltage
16.0V
16.0V
16.0V 9~17V
①
Charging Limit Voltage
15.0V
15.0V
15.0V 9~17V
①
Over Voltage Reconnect Voltage
15.0V
15.0V
15.0V 9~17V
①
Equalize Charging Voltage
14.6V
——
14.8V 9~17V
①
Boost Charging Voltage
14.4V
14.2V
14.6V 9~17V
①
Float Charging Voltage
13.8V
13.8V
13.8V 9~17V
①
Boost Reconnect Charging Voltage
13.2V
13.2V
13.2V 9~17V
①
Low Voltage Reconnect Voltage
12.6V
12.6V
12.6V 9~17V
①
Under Voltage Warning Reconnect Voltage
12.2V
12.2V
12.2V 9~17V
①
Under Volt. Warning Volt.
12.0V
12.0V
12.0V 9~17V
①
Low Volt. Disconnect Volt.
11.1V
11.1V
11.1V 9~17V
①
Discharging LimitVoltage
10.6V
10.6V
10.6V 9~17V
①
Equalize Duration (min.)
120
——
120
0~180
Boost Duration (min.)
120
120
120
10~180
Battery type Voltage parameter
LiFePO
4
(4S)
Li-NiCoMn
(3S)
User
Over Voltage Disconnect Voltage
15.6V
13.5V
9~17V
①
Charging Limit Voltage
14.6V
12.6V
9~17V
①
Over Voltage Reconnect Voltage
14.5V
12.5V
9~17V
①
Equalize Charging Voltage
14.5V
12.5V
9~17V
①
Boost Charging Voltage
14.5V
12.5V
9~17V
①
Float Charging Voltage
13.8V
12.2V
9~17V
①
Boost Reconnect Charging Voltage
13.2V
12.1V
9~17V
①
Low Voltage Reconnect Voltage
12.4V
10.5V
9~17V
①
Under Voltage Warning Reconnect Voltage
12.5V
11.0V
9~17V
①
Under Volt. Warning Volt.
12.0V
10.5V
9~17V
①
Low Volt. Disconnect Volt.
11.0V
9.3V
9~17V
①
Discharging LimitVoltage
10.8V
9.3V
9~17V
①
WARNING:The voltage parameters of lithium battery can be set, but you
must refer to the voltage parameters of lithium battery BMS.
WARNING: The required accuracy of BMS shall be at least 0.2V. If the
deviation is higher than 0.2V, the manufacturer will assume no liability
for any system malfunction caused by this.