![Sunways AT 2700 Скачать руководство пользователя страница 84](http://html1.mh-extra.com/html/sunways/at-2700/at-2700_user-manual_1401168084.webp)
84
Malfunction
Description
Remedies
303:Overtmp.
Your solar inverter is designed
for an ambient temperature of
up to +40°C. When a specified
temperature threshold of the
heat sink is reached, the output
power is reduced linearly.
Should the heat sink tempera-
ture nevertheless continue to
increase, feeding is stopped.
After the heat sink tempera-
ture drops, the solar inverter
starts up again automatically.
The maximum permissible
ambient temperature has been
exceeded.
➡
The installation location
is not suitable. Please find
another installation location.
The necessary air circulation
was not taken into account
during installation.
➡
Clean the solar inverter, if
dirt prevents cooling.
➡
Observe the installation
distances specified in the
manual.
Objects were laid on the heat
sink and unimpaired convec-
tion was prevented.
➡
Remove the objects.
84
Malfunction
Description
Remedies
304:Mains rel.
The AT solar inverter checks the
operation of the mains relay
prior to every switch-on. An
error was detected during this
check.
➡
Restart the solar inverter.
If the error still occurs, please
contact the technical hotline.
The phone number is provided
on the back of the manual.
305:AFI Test
The AT solar inverter checks the
operation of its residual-cur-
rent monitoring unit prior to
every switch-on. An error was
detected during this check.
➡
Restart the solar inverter.
If the error still occurs, please
contact the technical hotline.
The phone number is provided
on the back of the manual.
Содержание AT 2700
Страница 1: ...User Manual for Sunways Solar Inverter AT 5000 AT 4500 AT 3600 AT 2700...
Страница 8: ...1 0 Product Description...
Страница 16: ...16 2 0 Safety precautions...
Страница 22: ...22 3 0 Installation...
Страница 46: ...46 4 0 Commissioning...
Страница 56: ...56 5 0 Operation...
Страница 96: ...96 6 0 System monitoring...
Страница 103: ...103 4 Click in the Status window on Properties 5 Mark Internet Protocol TCP IP and click on Properties again...
Страница 129: ...129...
Страница 130: ...130 7 0 Appendix...
Страница 135: ...135 Efficiency of AT 5000 Output power W...
Страница 136: ...136 Efficiency of AT 4500 Output power W...
Страница 137: ...137 Efficiency of AT 3600 Output power W...
Страница 138: ...138 Efficiency of AT 2700 Output power W...
Страница 140: ......
Страница 141: ...C F Werbung und Dokumentation Villingen Schwenningen www cundf de...