37
AC bayonet connector
The AC bayonet connector is permissible
for cable sheath diameters from 13 mm
to 20 mm.
The following sequence must be ob-
served during assembly:
1. Strip the voltage-free line and the
cable ends.
10
52,5 (PE 55)
For lines with a cable sheath diameter
from 16 to 20 mm, the cable gland must
be adapted accordingly. To do this, cut
out the inner section of the blue sealing
ring.
2. Slid the cable gland and the plug
housing onto the line.
3. Connect the cable ends to the plug
terminals in accordance with the pin
assignment.
Tightening torque: 0.7 Nm.
!
CAUTION
Observe the pin assignment of the AC
bayonet connector. An incorrect assign-
ment can result in the unit being de-
stroyed.