SWL2820 Operator’s Manual
77
5.5.9 TROUBLE SHOOTING
Trouble
Cause
Solution
Electric system
Lamps do not work properly
even with engine running at
high speed
Fault cables
Check and repair any
loose terminal and
connection
Lamps come on
intermittently with engine
running
Faulty fan belt tension
Check the belt tension
and adjust it or change it if it
is necessary
Faulty alternator
Change
Charge warming light dose
not go out when the engine
running, even at high speed
Faulty cables
Check and repair
Alternator emits abnormal
noise
Faulty alternator
Change
Faulty cables
Check and repair
Battery charge
insufficient
Charge battery
Starter does not work with
key in START position
Faulty main fuse
Change
Starter pinion engages and
disengages while starting
engine
Battery charge
insufficient
Charge battery
Faulty bulb
Change
Engine oil pressure warming
light does not come on when
engine is stopped
Faulty pressure sensor
Change
Faulty bulb
Change
Charging warming light
dose not come on when
engine is stopped
Faulty cables
Check and repair
Hydraulic system
No oil in the tank
Refill oil
Faulty pump
Check, then repair or
change
Pumps emit abnormal noise
Hydraulic oil
unsuitable for the
temperature
Change the oil
Faulty pump
Check, then repair or
change
Max. pressure valve
setting incorrect, or valves
closed due to impurities
Reset or change
Equipment moves only at
low speed
Dirty drain filter
Change
Содержание SWL 2021 Series
Страница 10: ...SWL2820 Operator s Manual 9 Float Tail warning Oil level Diesel Oil Oil filter...
Страница 25: ...SWL2820 Operator s Manual 24 3 1 3 MACHINE DISTRIBUTION 1 7 2 3 4 5 6 8 9 10...
Страница 45: ...SWL2820 Operator s Manual 44 A B C H G D E F...
Страница 89: ...SWL2820 Operator s Manual 88 SWL2820 Hydraulic Diagram...
Страница 90: ...SWL2820 Operator s Manual 89 Lift Tilt Auxiliary SWL2820 Hydraulic Diagram For High Flow Optional...