![Sunsystem SWUP EXT Series Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/sunsystem/swup-ext-series/swup-ext-series_installation-and-operation-manual_1400659009.webp)
9
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
SWUP EXT
120
SWUP EXT
150
SWUP EXT
200
Energy class
С
Capacity
L
120
150
200
Height / Min. vertical clearance
mm
853/1050
1010/1170
1300/1500
Diameter
D, mm
Ø 600
Ø 600
Ø 600
Insulation
50 mm rigid PPU
Oper. pressure / Max. temperature water tank
bar/
0
C
10/95
10/95
10/95
Test pressure of tank/Max. temperature coil
bar/
0
C
25/160
25/160
25/160
Weight
kg
88
93
104
Cold water inlet
A, mm
R3/4”
R3/4”
R3/4”
Hot water outlet
B, mm
R3/4”
R3/4”
R3/4”
Recirculation
R, mm,
R3/4”
R3/4”
R3/4”
Coil capacity S1 L
7.5
8.2
8.7
Heat exchange surface S1
m
2
1.2
1.3
1.32
Coil inlet/ Coil outlet S1
S1i/ S1o, mm
R3/4” / R3/4”
R3/4” / R3/4”
R3/4” / R3/4”
Prolonged power acc. to DIN 4708;
10°C/80°C/45°C, S1
L/h (kW)
980(39.9)
1100(44.8)
1130(45.7)
NL- power coefficient at 60°C, S1
NL 60°C
1.8
2.1
2.2
Pressure drop Δp, S1
Δp, mbar
100
120
125
Inspection opening/Flange
O,Ø, mm
DN 110
DN 110
DN 100
Drain sleeve
Y, mm,
Rp1/2”
Rp1/2”
Rp1/2”
Anode
P,mm
”
M8
M8
M8
Additional sensor sleeve
Z, mm
Adjustable feet
Optional equipment
Содержание SWUP EXT Series
Страница 1: ...serie SWUP EXT vertical 120 150 200 L Solar Water Tanks INSTALLATION and OPERATION MANUAL Versie 0 2...
Страница 2: ...2 INSTALLATION and OPERATION MANUAL...
Страница 8: ...8 INSTALLATION and OPERATION MANUAL 4 TECHNICAL PARAMETERS 4 1 SWUP EXT with one coil...
Страница 15: ...15 INSTALLATION and OPERATION MANUAL...
Страница 16: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...