Sunsystem SWUP EXT Series Скачать руководство пользователя страница 14

14

 

     

INSTALLATION and OPERATION MANUAL

                     

     INSTALLATION and OPERATION MANUAL

b) 

The liability of NES Ltd. under 

this Warranty Certificate is limited to the 

abovementioned  obligations  and  up  to 

the sum in accordance with the purchase 

receipt of the product to be claimed; ex-

cluded is any liability for indirect damages 

such as loss of data at information appli

-

cations, loss of production, thermal vari

-

ations  at  the  service,  etc.  which  do  not 

violate  the  applicable  regulations  of  any 

country concerning product liability. 

c) 

Abovementioned  warranty  limi

-

tations  will  be  applied  in  any  cases,  and 

when they do not violate the regulations 

in any country concerning product liabil-

ity. If this circumstance annuls some of 

preceding  clauses,  annulment  will  refer 

only to this clause, while the others will 

remain  valid.  In  conclusion,  excluded  is 

application of any Regulation pointed out 

in this Warranty which violates the Law 

23/July 10, 2003 and Directive 1999/44/

EU concerning water heaters and their 

use on the territory of the EU.

d) 

Any other warranty right that is 

not  mentioned  in  this  Warranty  Certifi

-

cate is excluded.

7. RECYCLING AND WASTE DISPOSAL

Submit all packaging material for recy-

cling  according  to  the  local  regulations 

and requirements.

At the end of life cycle of each product its 

components are due to be disposed of in 

conformity with regulatory prescriptions. 

According  to  Directive  2002/96/EC  re

-

garding electrical and electronic equip-

ment waste, disposal thereof is required 

separately from the normal flow of solid 

household waste. Obsolete equipment 

shall be collected separately from oth-

er recyclable waste containing materials 

with  adverse  effect  on  health  and  envi

-

ronment.

Expired appliances must be collected sep-

arately from other recyclable waste con-

taining substances hazardous to health 

and environment.

Both metal and non-metal parts are sold 

out to licensed organizations for recycla

-

ble metal or non-metal waste collection. 

In any case they should not be treated as 

household waste.

Содержание SWUP EXT Series

Страница 1: ...serie SWUP EXT vertical 120 150 200 L Solar Water Tanks INSTALLATION and OPERATION MANUAL Versie 0 2...

Страница 2: ...2 INSTALLATION and OPERATION MANUAL...

Страница 3: ...ION TO INSTALLER 4 2 DESCRIPTON ON WATER TANKS 5 3 CONNECTING OF SAFETY RELIEF VALVE TO WATER TANK 7 4 TECHNICAL PARAMETERS 8 4 1 SWUP EXT with one coil 8 4 2 SWUP SLIM EXT with one coil 10 5 TRANSPOR...

Страница 4: ...Before commissioning check the installation for leaks Do not exceed the working pressure of 10 bar Dear Customers We strongly hope that the appliance you have bought from us will contribute to creatin...

Страница 5: ...e quality of the insulation of a water tanks is a key factor for its heat conservation capability and energy efficiency All water tanks SWUP EXT series have a high efficiency insulation DIN 4753 part...

Страница 6: ...ed electric heater with a built in thermostat with double protection with a regulation range from 10 C to 70 C temperature of operation of the emergency protection 80 C The connection of the electric...

Страница 7: ...4 Safety relief pressure valve 5 Cold water inlet water tank 6 Stopcock drainage Stop Shut off valves should never be installed between a safety relief valve and the tank It is recommended once a yea...

Страница 8: ...8 INSTALLATION and OPERATION MANUAL 4 TECHNICAL PARAMETERS 4 1 SWUP EXT with one coil...

Страница 9: ...water inlet A mm R3 4 R3 4 R3 4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 7 5 8 2 8 7 Heat exchange surface S1 m2 1 2 1 3 1 32 Coil inlet Coil outlet S1...

Страница 10: ...10 INSTALLATION and OPERATION MANUAL 4 2 SWUP SLIM EXT with one coil R S1o A S1i O Z B P T U Di P Z D S1o O S1i B A R Y H...

Страница 11: ...4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 6 4 8 2 8 7 Heat exchange surface S1 m2 1 1 25 1 3 Coil inlet Coil outlet S1 S1i S1o mm R3 4 R3 4 R3 4 R3 4...

Страница 12: ...diately after any defects have been de termined except for in case of noticeable defects at the moment of purchase in which case the customer must make the claim at the shop immediately after notic in...

Страница 13: ...warranty obliga tions which might originate from external pressure of other circumstances outside NES Ltd tification number has been modified re moved or blurred or cannot be expressly attested c Dama...

Страница 14: ...10 2003 and Directive 1999 44 EU concerning water heaters and their use on the territory of the EU d Any other warranty right that is not mentioned in this Warranty Certifi cate is excluded 7 RECYCLIN...

Страница 15: ...15 INSTALLATION and OPERATION MANUAL...

Страница 16: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...

Отзывы: