background image

7

 

     

INSTALLATION and OPERATION MANUAL

                     

     INSTALLATION and OPERATION MANUAL

1

Cold water inlet - water supply

2

Check (return) valve

3

Tee

4

Safety (relief) pressure valve

5

Cold water inlet -  water tank

6

Stopcock (drainage)

Stop (Shut-off) valves should 

never be installed between a 

safety (relief)  valve and the tank.

It is recommended once a year to 

check the operation of the safety 

valve. 

3.  CONNECTING OF SAFETY RELIEF VALVE TO WATER TANK

Содержание SWUP EXT Series

Страница 1: ...serie SWUP EXT vertical 120 150 200 L Solar Water Tanks INSTALLATION and OPERATION MANUAL Versie 0 2...

Страница 2: ...2 INSTALLATION and OPERATION MANUAL...

Страница 3: ...ION TO INSTALLER 4 2 DESCRIPTON ON WATER TANKS 5 3 CONNECTING OF SAFETY RELIEF VALVE TO WATER TANK 7 4 TECHNICAL PARAMETERS 8 4 1 SWUP EXT with one coil 8 4 2 SWUP SLIM EXT with one coil 10 5 TRANSPOR...

Страница 4: ...Before commissioning check the installation for leaks Do not exceed the working pressure of 10 bar Dear Customers We strongly hope that the appliance you have bought from us will contribute to creatin...

Страница 5: ...e quality of the insulation of a water tanks is a key factor for its heat conservation capability and energy efficiency All water tanks SWUP EXT series have a high efficiency insulation DIN 4753 part...

Страница 6: ...ed electric heater with a built in thermostat with double protection with a regulation range from 10 C to 70 C temperature of operation of the emergency protection 80 C The connection of the electric...

Страница 7: ...4 Safety relief pressure valve 5 Cold water inlet water tank 6 Stopcock drainage Stop Shut off valves should never be installed between a safety relief valve and the tank It is recommended once a yea...

Страница 8: ...8 INSTALLATION and OPERATION MANUAL 4 TECHNICAL PARAMETERS 4 1 SWUP EXT with one coil...

Страница 9: ...water inlet A mm R3 4 R3 4 R3 4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 7 5 8 2 8 7 Heat exchange surface S1 m2 1 2 1 3 1 32 Coil inlet Coil outlet S1...

Страница 10: ...10 INSTALLATION and OPERATION MANUAL 4 2 SWUP SLIM EXT with one coil R S1o A S1i O Z B P T U Di P Z D S1o O S1i B A R Y H...

Страница 11: ...4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 6 4 8 2 8 7 Heat exchange surface S1 m2 1 1 25 1 3 Coil inlet Coil outlet S1 S1i S1o mm R3 4 R3 4 R3 4 R3 4...

Страница 12: ...diately after any defects have been de termined except for in case of noticeable defects at the moment of purchase in which case the customer must make the claim at the shop immediately after notic in...

Страница 13: ...warranty obliga tions which might originate from external pressure of other circumstances outside NES Ltd tification number has been modified re moved or blurred or cannot be expressly attested c Dama...

Страница 14: ...10 2003 and Directive 1999 44 EU concerning water heaters and their use on the territory of the EU d Any other warranty right that is not mentioned in this Warranty Certifi cate is excluded 7 RECYCLIN...

Страница 15: ...15 INSTALLATION and OPERATION MANUAL...

Страница 16: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...

Отзывы: