background image

4

 

     

INSTALLATION and OPERATION MANUAL

                     

     INSTALLATION and OPERATION MANUAL

the fitting of theinstallation with safety 

devices.

• safety during installation - personal 

protective equipment

i

Use only original parts

1.1. Requirements to water tank 

installation room. 

When choosing a room for tank installation 

observe the following requirements:
• to have a drainage channel. Some 

maintenance procedures require draining 

of all water from the tank.
• Thermal insulation of the room. This 

provides efficiency of the appliance and 

prevents the water from freezing.

1.2. Requirements for installation:

• The length of connecting pipes between 

the water tank and consumer must be as 

short as possible.

•  Before  connecting  the  boiler  to  the 

installation,  check  all  screw  connections 

(bolt  inspection  cover  flange,  plug  and 

anode).  In very rare cases - during 

transportation,  loading  and  unloading 

operations -  the screw connections may 

be loosen.

•  The  tightening  torque  for  flanges  is 

around 35 Nm.

•  Before  commissioning,  check  the 

installation for leaks

• Do not exceed the working pressure of 

10 bar.

       

            Dear Customers,

We strongly hope that the appliance 

you have bought from us will contribute 

to creating comfort at you homes and 

decreasing the energy expenditure.

This manual contains important 

information for the safe and correct 

installation,  start-up  and  trouble-free 

operation and maintenance of the water 

heater.

The water heater can be used for 

producing of domestic hot water (DHW) 

only in the manner described in this 

manual.

The application and any other was the 

area of operation is not recommended by 

the manufacturer and is not responsible 

for the occurrence of defects or failures.

1. INSTRUCTION TO INSTALLER

The preparation, installation 

and commissioning must be 

performed by an authorized 

installer / service.

During  installation  and  operation,  the 

country specific requirements and 

regulations must be observed:

• local construction regulations on 

installation of water tank; weight of the 

boiler to comply with the stability of the 

floor of the room where it will be installed.

• regulations and norms concerning 

Содержание SWUP EXT Series

Страница 1: ...serie SWUP EXT vertical 120 150 200 L Solar Water Tanks INSTALLATION and OPERATION MANUAL Versie 0 2...

Страница 2: ...2 INSTALLATION and OPERATION MANUAL...

Страница 3: ...ION TO INSTALLER 4 2 DESCRIPTON ON WATER TANKS 5 3 CONNECTING OF SAFETY RELIEF VALVE TO WATER TANK 7 4 TECHNICAL PARAMETERS 8 4 1 SWUP EXT with one coil 8 4 2 SWUP SLIM EXT with one coil 10 5 TRANSPOR...

Страница 4: ...Before commissioning check the installation for leaks Do not exceed the working pressure of 10 bar Dear Customers We strongly hope that the appliance you have bought from us will contribute to creatin...

Страница 5: ...e quality of the insulation of a water tanks is a key factor for its heat conservation capability and energy efficiency All water tanks SWUP EXT series have a high efficiency insulation DIN 4753 part...

Страница 6: ...ed electric heater with a built in thermostat with double protection with a regulation range from 10 C to 70 C temperature of operation of the emergency protection 80 C The connection of the electric...

Страница 7: ...4 Safety relief pressure valve 5 Cold water inlet water tank 6 Stopcock drainage Stop Shut off valves should never be installed between a safety relief valve and the tank It is recommended once a yea...

Страница 8: ...8 INSTALLATION and OPERATION MANUAL 4 TECHNICAL PARAMETERS 4 1 SWUP EXT with one coil...

Страница 9: ...water inlet A mm R3 4 R3 4 R3 4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 7 5 8 2 8 7 Heat exchange surface S1 m2 1 2 1 3 1 32 Coil inlet Coil outlet S1...

Страница 10: ...10 INSTALLATION and OPERATION MANUAL 4 2 SWUP SLIM EXT with one coil R S1o A S1i O Z B P T U Di P Z D S1o O S1i B A R Y H...

Страница 11: ...4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 6 4 8 2 8 7 Heat exchange surface S1 m2 1 1 25 1 3 Coil inlet Coil outlet S1 S1i S1o mm R3 4 R3 4 R3 4 R3 4...

Страница 12: ...diately after any defects have been de termined except for in case of noticeable defects at the moment of purchase in which case the customer must make the claim at the shop immediately after notic in...

Страница 13: ...warranty obliga tions which might originate from external pressure of other circumstances outside NES Ltd tification number has been modified re moved or blurred or cannot be expressly attested c Dama...

Страница 14: ...10 2003 and Directive 1999 44 EU concerning water heaters and their use on the territory of the EU d Any other warranty right that is not mentioned in this Warranty Certifi cate is excluded 7 RECYCLIN...

Страница 15: ...15 INSTALLATION and OPERATION MANUAL...

Страница 16: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...

Отзывы: