Sunsystem SWUP EXT Series Скачать руководство пользователя страница 12

12

 

     

INSTALLATION and OPERATION MANUAL

                     

     INSTALLATION and OPERATION MANUAL

   5

. TRANSPORT AND PACKAGING

We recommend to transport  the water 

tank to the installation site in its packaging 

placed on the pallet, and stretch foil. 

During  transport  and  installation, 

depending  on  the  weight,  appropriate 

safety equipment must be used in 

accordance with Directive 2006/42/EC.

When transporting items weighing more 

than  30  kg,  the  use  of  pallet  jack,  fork 

truck or other hoisting devices is a must

.

6. WARRANTY

6.1. Manufacturing defects and materials 

guarantee

NES Ltd. expressly guarantees that the 

products it manufactures shall be free 

from defects in  materials and workman-

ship which can prevent from normal op-

eration  under  proper  and  normal    use, 

installation  and  maintenance  for  the  in

-

tended  functions  of  the  products,  for  a 

period set out in the warranty certificate 

of the respective water heater model you 

have bought. The warranty period begins 

from the date indicated in the purchase 

invoice. If a product or any component 

there of is determined to be defective in 

manufacture or materials, NES Ltd. will re

-

pair or replace the defective component 

or product

 

6.2.  Exclusions  and  Limitations  of  War-

ranty Coverage

a) The customer can claim warranty during 

warranty period of respective product im

-

mediately after any defects have been de

-

termined, except for in case of noticeable 

defects  at  the  moment  of  purchase,  in 

which case the customer must make the 

claim at the shop immediately after notic

-

ing the defect as it is provided for in the 

general conditions of sale.

1)  Accidents,  installation  on  movable 

structures,  negligence,  improper  care  or 

nonconformity.

2) Failure to observe the installation, use 

and  maintenance  instructions  set  forth 

in  the  installation  manual  of  respective 

product.

3) Improper installation and use as well as 

changes, especially if they are not made 

by    authorized  after-sale  service  person

-

nel of NES Ltd.

4) Testing and operation pressures greater 

that values established by NES Ltd. and set 

forth  in product manuals, or use of water 

with characteristic values exceeding:

- Dissolvable salts – 500 mg/l;

- Calcium carbonate – 200 mg/l;

- Free carbon dioxide – 50 mg/l;

- ph content – minimum 5 and maximum 

12.

5) Freeze, flood, natural disasters or third 

party actions as well as any interventions 

into normal functioning conditions of wa

-

ter heaters and the control of NES Ltd. 

The customer as well should monitor the 

anticorrosion system (magnesium anodе). 

He should periodically check the magne-

sium anode and replace it depending 

on  the  geographic  location  at  intervals 

depending  on  the  type  of  water (soft  of 

hard) of the region where the water heat-

er is being used.

b) The warranty certificate is considered 

void for water heaters whose serial iden-

Содержание SWUP EXT Series

Страница 1: ...serie SWUP EXT vertical 120 150 200 L Solar Water Tanks INSTALLATION and OPERATION MANUAL Versie 0 2...

Страница 2: ...2 INSTALLATION and OPERATION MANUAL...

Страница 3: ...ION TO INSTALLER 4 2 DESCRIPTON ON WATER TANKS 5 3 CONNECTING OF SAFETY RELIEF VALVE TO WATER TANK 7 4 TECHNICAL PARAMETERS 8 4 1 SWUP EXT with one coil 8 4 2 SWUP SLIM EXT with one coil 10 5 TRANSPOR...

Страница 4: ...Before commissioning check the installation for leaks Do not exceed the working pressure of 10 bar Dear Customers We strongly hope that the appliance you have bought from us will contribute to creatin...

Страница 5: ...e quality of the insulation of a water tanks is a key factor for its heat conservation capability and energy efficiency All water tanks SWUP EXT series have a high efficiency insulation DIN 4753 part...

Страница 6: ...ed electric heater with a built in thermostat with double protection with a regulation range from 10 C to 70 C temperature of operation of the emergency protection 80 C The connection of the electric...

Страница 7: ...4 Safety relief pressure valve 5 Cold water inlet water tank 6 Stopcock drainage Stop Shut off valves should never be installed between a safety relief valve and the tank It is recommended once a yea...

Страница 8: ...8 INSTALLATION and OPERATION MANUAL 4 TECHNICAL PARAMETERS 4 1 SWUP EXT with one coil...

Страница 9: ...water inlet A mm R3 4 R3 4 R3 4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 7 5 8 2 8 7 Heat exchange surface S1 m2 1 2 1 3 1 32 Coil inlet Coil outlet S1...

Страница 10: ...10 INSTALLATION and OPERATION MANUAL 4 2 SWUP SLIM EXT with one coil R S1o A S1i O Z B P T U Di P Z D S1o O S1i B A R Y H...

Страница 11: ...4 Hot water outlet B mm R3 4 R3 4 R3 4 Recirculation R mm R3 4 R3 4 R3 4 Coil capacity S1 L 6 4 8 2 8 7 Heat exchange surface S1 m2 1 1 25 1 3 Coil inlet Coil outlet S1 S1i S1o mm R3 4 R3 4 R3 4 R3 4...

Страница 12: ...diately after any defects have been de termined except for in case of noticeable defects at the moment of purchase in which case the customer must make the claim at the shop immediately after notic in...

Страница 13: ...warranty obliga tions which might originate from external pressure of other circumstances outside NES Ltd tification number has been modified re moved or blurred or cannot be expressly attested c Dama...

Страница 14: ...10 2003 and Directive 1999 44 EU concerning water heaters and their use on the territory of the EU d Any other warranty right that is not mentioned in this Warranty Certifi cate is excluded 7 RECYCLIN...

Страница 15: ...15 INSTALLATION and OPERATION MANUAL...

Страница 16: ...ISO 9001 BUREAU VERITAS Certification tel 359 700 17 343 www burnit bg...

Отзывы: