1. EXPLANATION OF SYMBOLS AND SAFETY
INSTRUCTIONS
1.1. Explanation of symbols
CAUTION! – Important recommendation or warning
concerning safety conditions during installation and
operation of the pellet burner
DANGER! – fault or improper use may cause injury or
be hazardous to life of humans or animals.
FIRE HAZARD! – fault or improper installation and
operation may cause fire.
INFORMATION – Important information on the
proper operation of the product.
1.2. Requirements to Dual-chamber boiler installation
room
This manual contains important information for the safe and
correct installation, start-up and trouble-free operation and
maintenance of the boiler.
The Dual-chamber boiler can be used for heating rooms only
in the manner described in this manual.
The application and any other was the area of operation
is not recommended by the manufacturer and is not
responsible for the occurrence of defects or failures.
Note the boiler type data on the factory rating label and
the technical data provided in chapter 13 in order to ensure
proper operation of the product.
1.2.1. Instructions to boiler installer
During installation and operation, the country-specific
requirements and regulations must be observed:
• Local construction regulations on installation, air supply
and exhaust gas extraction as well as chimney connection.
• Regulations and norms concerning the fitting of the heating
installation with safety devices.
• Required installation of a smoke detector in the boiler
room.
Use only original
BURNiT
parts
WARNING! Installation and setup of pellet burner
should be done by an authorized specialist / service
shop and must follow the safety instructions and
rules of operation.
DANGER of intoxication, suffocation.
Inadequate inflow of fresh air to the boiler room
may result in dangerous leak of exhaust gases
during boiler operation.
- Make sure the air inlets and exhaust gas outlets are
not clogged or closed.
- If faults are not remedied immediately, the boiler
must not be operated.
- The user must be provided with written instructions
on the fault and the hazard it entails.
DANGER of fire
when burning flammable materials
or liquids.
- Flammable materials/liquids must not be left in
close proximity of the burner and heating boiler.
- Instruct system user of the allowed minimum
clearances from surrounding objects.
It is mandatory to assure a backup power generator
of corresponding rated power! (see 12.2)
Customer must undergo boiler operation/
maintenance training by authorized installer/
service shop.
1.2.2. Instructions to installation user
DANGER of intoxication or explosion
Toxic gases may be discharged when burning
waste, plastics, liquids.
- Use only the fuels indicated in this manual.
- In case of danger of explosion, ignition or discharge
of exhaust gases in the room, stop the pellet burner
from operation.
CAUTION! Danger of injury / damage of system due
to incompetent operation.
- The boiler must be serviced only by persons
familiar with the operation manual.
- As user, you are only allowed to start the boiler
up, adjust the temperature of the boiler, shut the
boiler down and clean it.
- Unattended children must not be allowed access to
premises with running boiler inside.
It is mandatory to assure a backup power generator
of corresponding rated power! (see 12.2)
Customer must undergo boiler operation/
maintenance training by authorized installer/
service shop.
Safety rules for user operation:
- Operate the pellet burner on recommended fuel only, and
to that end you must regularly inspect the boiler room.
- Do not use both cameras for burning fuel at the same time.
Before starting the boiler, make sure there is no residual
fuel in one of the two cameras and / or burner.
- Do not use flammable liquids for ignition or increase of
burner output.
- Collect ash in lid-covered fireproof containers.
- Clean the burner surface using non-flammable agents only.
- Do not place flammable objects onto the burner housing
and heating boiler cabinet or in their proximity. (see
diagram 1
for the minimum clearances)
- Do not store flammable materials in the boiler room.
- Boilers, chimneys and other connections of mounted
burner must meet standards for fire and emergency safety
of the country.
- It is mandatory to strictly observe instructions for
connecting the burner to power network as well as to all
peripherals.
- Structural changes to Dual-chamber boiler by user can
cause damage to equipment or injury.
- Do not allow contact transmission of electrical wire or touch
any part of the boiler, where the surface temperature can
exceed
70°C
.
- This manual should be kept throughout the lifetime of the
boiler.