11
EN
TECHNICAL PASSPORT INSTALLATION and OPERATION MANUAL
10.2.2. Burner start-up „Switch mode“
Burner start-up. After pressing the
“
F
” button and using the navigation
arrows, the “
Auto
” menu is
selected. Pressing the “
F
” button
will open the next page of the
menu.
Set the priority mode of the burner
through “navigation arrows.”
-
CH Priority
– Priority pump
heating system
-
DHW Priority
–
Priority pump for
domestic hot water
-
Parallel Pumps
– parallel operation of both pumps.
-
Summer Mode
– Summer mode. Burner works for heating
of domestic hot water only.
Select the desired option using the navigation arrows. Use
the „
Enter
” button to open the next page of the menu.
i
Important – The use of “External room thermostat
for the burner” option (Thermostat) is active only if
option is selected (CH Priority – priority of central
heating installation pump).
10.2.3. Automatic mode of operation „Auto“
The burner goes into automatic
mode of operation „
Auto
“. In this
operation mode the ignition and
the combustion process are
automatic as well as the pump
control. The burner operates in this
mode until the maximum preset temperature has been
reached. It then enters into “
Suspend
” mode.
10.2.4. Burner shut-down „Standby“
Pressing the “
F
” button will take
you to the main menu and by using
the navigation arrows you can
select the “
Standby
” menu and
confirm the selection by pressing
“
F
”. The burner goes into
extinguishing modeSet the temperature to start heating
pump.
10.2.5. Setting up delayed start “Programme”
From the start-up screen, press „
F
”
to enter into the burner status
„
Switch Mode
“. Use the navigation
arrows to select the “
Programme
”
menu and confirm your selection
by pressing the “
F
” button.
This will open a menu where within a 24-hour period you
can set up to 3 /three/ delayed start-ups and shut-downs of
the burner.
Example:
The picture shows the
first checkmark being set and next
to it is the start-up time at 06:00
and burner shut-down time at
22:00.
Programming desired time:
- Activate the checkmark in the box
Select the desired option using the navigation arrows. Use
the „
Enter
” button to open the next page of the menu.
Heating priority selection
Menu.
From this menu you can select the
priority of one of the two pumps:
(
CH Priority
) or (
DHW Priority
).
Parallel Pumps
– parallel operation
of both pumps.
Summer Mode
.
Important
– The use of “
External thermostat for the burner
”
option is active only if option is selected (
CH Priority
–
priority of central heating installation pump).
Use the navigation arrows to select the desired priority and
press the “
F
” button to open the next page.
After all settings have been confirmed, the burner will
initiate ignition sequence according to the input parameters.
10.2.6. Set MANUAL mode
From the start-up screen, press „
F
”
to enter into the burner status
„
Switch Mode
“. Use the navigation
arrows to select the “
Manual
”
menu and confirm your selection
by pressing the
“F”
button.
Upon startup in manual mode there are two options to
choose from – wood-only mode (described in instruction
manual) and automatic burner startup upon exhaustion of
firewood. In
„Switch Mode”
upon selecting
„Manual”
a
submenu
„Manual Mode”
is displayed.
To select a mode in which the boiler
will self-switch from manual to
automatic upon exhaustion of
wood tick the
Auto
box.
If no tick, upon exhaustion of wood
the boiler will go out and will need
re-ignition to restart.
Heating priority selection
Menu.
From this menu you can select the
priority of one of the two pumps:
(
CH Priority
) or (
DHW Priority
).
Parallel Pumps
– parallel operation of both pumps.
Important – The use of “External thermostat for the burner”
option is active only if option is selected (CH Priority –
priority of central heating installation pump).
Use the navigation arrows to select the desired priority and
press the “F” button to open the next page.
Set fan speed
Use the navigation arrows to set
fan speed when boiler is operating
in Manual mode (combustion of
wood and / or coal in the upper
chamber)
CAUTION! It is recommended to use the same fuel
throughout the heating season.
CAUTION! Important: You use a burner whose
carbon footprint values are approximately (СО=100
ppm), which is 2.5 times lower than the maximum
allowed limits for harmful emissions in the EU
Member States. Thus you can reduce the amount
of harmful emission and contribute to environment
protection.
Содержание BURNIT CombiBurn DC-A Series
Страница 65: ...65 65 1 3 2 4 9 2 4 5 11 10 8 9 6 7...
Страница 66: ...66 66 5 6 7 3 1 2 5 4...
Страница 67: ...67 67 8...
Страница 69: ...69 69 10 11...
Страница 70: ...70 70 12...
Страница 71: ......