96
•
You can see the movement of the marks towards the image as the
Mark Position
is decreased. Because of
the shape of the ox, this shouldn’t be an issue with the location of the registration marks relative to the
printed image. However, if a design is more rectangular, such as a wine bottle label, then it is much easier
to see that it could cause issues if the
Mark Position
is too small:
•
IMPORTANT:
Using the
Array
plus
Array Mark
options on the Skycut’s control panel allows for more
flexibility when working with multiple registration marks, such as being able to only scan one mark when
there are repeats. This is covered in
Section 3.09.2
.
3.09 PNC from USB Flash Drive
3.09.1 PNC from Flash Drive
– Single Cut
•
To perform a print and cut project from the control panel, first perform
Steps (1)
– (11)
from
Section 3.04.2
.
However, before clicking on
Done
to close the
Vinyl Spooler
window, click on the
Connection
tab and
change the
Port
to
U-Disk
from the drop-down menu. Then click on
Done
:
Mark Position
= 0.307 in
Should work
Mark Position
= 0.307 in
Mark Position
= 0.057 in
Mark Position
= 0.557 in
Will work
Mark Position
= 0.057 in
Will not work
Mark Position