8
Enable/disable to save positioning
percentage, record and save current
positioning every time when the curtain moves
to specified position, if the working mode is
configured as light mode, record on/off state.
0x00: disable
0x01: enable
0x04(4)
1
1
Working mode
0: light mode
1: Shutter mode without positioning
2: Shutter mode with positioning
3: venetian mode (up/down and slats rotation)
0x03(3)
1
2
Configuration Command Class
Size
Description(decimal numeral )
Default Value
Parameter
Enable/disable the curtain motor controller to
report state change percentage threshold
(report only when change value at the
specified percentage), if enabled, report when
the value reaches both 0% and 99%. When the
working mode is configured as light mode, as
long as the state changes, the state change
percentage threshold will be reported.
SWITCH_MULTILEVEL_REPORT
0: disable to report actively
1-10: value to report, unit is one percent
0x02(2)
1
1
Enable/disable over current protection
0: disable
1: enable, when over current detected, there
are two methods to cancel alarm:
1. short press either switch button S1 or S2,
the alarm will last at least 1 minute and then be
cancelled.
2. re-power on the curtain motor controller
0x05(5)
1
1
Notification Type
NOTIFICATION_TYPE_POWER_MA
NAGEMENT(08)
Triggerring Event
POWER_MANAGEMENT_OVERCURRENT_DETE
CTED(06)
Notification Report
Over
Current
Alarm
When
connecting
to
resistive
load over
current
value
is
4 1A When
connecting
to
a
motor
or
capacitive
load, over
current
value
is
2.1A. Over
current
relays will be
closed.
:
,
.
.