4
Association Groups:
Association
Groups
Description
1. When press and hold down “K2” button for 10S to reset the
device, send "Device Reset Locally Notification" to associated
devices of this group to report factory reset information.
2. When over load detected, send "NOTIFICATION_REPORT" to
associated devices of this group.
Group 1
Group
Name
Lifeline
Max
Nodes
5
1. Calibration through the calibration button, short press the button twice, calibration starts automatically.
2. Set the configuration parameter 6 value to 1, calibration starts automatically.
Secene Control
Users can configure scenes using command class SCENE_ACTUATOR_CONF_SET, and activate the
scenes using command class SCENE_ACTIVATION_SET.
Activate Scenes Using Switch S1 S2
Users can configure configuration parameter 9 to decide whether to send scene activation command
using command class CENTRAL_SCENE_NOTIFICATION.
The scene ID and key attribute supported by switch S1 and S2 are as follows:
Default configuration of CENTRAL_SCENE_CONFIGURATION_SET is Slow Refresh = 1(send Key Held
Down every 55s when the switch is pressed and held down).
Association
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another
device is called association. In order to control a different device, the controlling device needs to maintain
a list of devices that will receive controlling commands. These lists are called association groups and they
are always related to certain events (e.g. button pressed). In case the event happens all devices stored in
the respective association group will receive a common wireless command.
Switch Number
S1
S2
Support Action type
Scene ID
Key Attribute
Short press once
Short press twice
Short press 3 times
Press and hold, release
1
1
1
1
2
2
2
2
Key pressed once
Key pressed twice
Key pressed 3 times
Key held down and released
Short press once
Short press twice
Short press 3 times
Press and hold, release
Key pressed once
Key pressed twice
Key pressed 3 times
Key held down and released