5
Set and unset associations:
(Note: All association information will be cleared automatically once the curtain motor controller is
excluded from a network.)
Set association by operating primary controller/gateway to send packets to the curtain motor controller:
The primary controller/gateway sends packets to the curtain motor controller using
"COMMAND_CLASS_ASSOCIATION" or "COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION".
Node Information Frame
The Node Information Frame is the business card of a Z-Wave device. It contains information about the
device type and the technical capabilities. The inclusion and exclusion of the device is confirmed by
sending out a Node Information Frame. Beside this it may be needed for certain network operations to
send out a Node Information Frame.
How to send out Node Information Frame:
When the curtain motor controller is set to inclusion/exclusion mode again, it will send out Node
Information Frame, there are 2 kinds of operation as follows:
1. triple press the K2 button, the curtain motor controller will be set to inclusion/exclusion mode, then send
out Node Information Frame.
2. When the curtain motor controller is under inclusion mode, there are two kinds of operation:
1) Triple press K2 button, the curtain motor controller will be set to inclusion mode again, and send out
Node Information Frame.
2) Power off and power on the curtain motor controller, it will be set to inclusion mode automatically, and
send out Node Information Frame.
Technical Data
Group 3
5
REP EP2
When endpoint 1 state changes, send
"SWITCH_MULTILEVEL_REPORT" to associated devices of this
group.
Group 2
REP EP1
5
When endpoint 2 state changes, send
"SWITCH_BINARY_REPORT" to associated devices of this group.
3. Report energy meter actively.
4. When action of S1 and S2 is detected, send
CENTRAL
_
SCENE
_
NOTIFICATION
_
V3
this group.
to associated devices of