9
When parameter 3 value configured as 0 (light
mode), configuration of button S1 and S2
control.
Value=0
Short press S1 to switch ON/OFF Q1. Press and
hold down S1 to switch ON Q1, then release to
switch OFF Q2.
Short press S2 to switch ON/OFF Q2. Press and
hold down S2 to switch ON Q2, then release to
switch OFF Q2.
Value=1
Short press S1 to switch ON/OFF Q1. When S1
is pressed and held down, then released, not
processed.
Short press S2 to switch ON/OFF Q2. When S2
pressed and held down, then released, not
processed.
Value=2
Press and hold down S1 to switch ON Q1, then
release to switch OFF Q2. When S1 short
pressed, not processed.
Press and hold down S2 to switch ON Q2, then
release to switch OFF Q2. When S2 short
pressed, not processed.
Value=3
Short press S1 or S2 to switch ON/OFF of both
Q1 and Q2 simultaneously. When S1 or S2
pressed and held down, not processed
Value=4
Press and hold down S1 to switch ON Q1 and
Q2. When S1 short pressed, not processed.
Press and hold down S2 to switch OFF Q1 and
Q2. When S2 short pressed, not processed.
0x07(7)
1
0
Only value 1 can be written in, which means
starting positioning calibration.
When read,
0x01: positioning calibration completed
0x00: positioning not calibrated
This parameter is only valid when parameter 3
configured as shutter mode with positioning or
venetian mode (up/down and slats rotation).
0x06(6)
1
0