90
Fans inside the inverter are used to cool the inverter during operation. If the fans do not op-
erate normally, the inverter may not be cooled down and inverter efficiency may decrease.
Therefore, it is necessary to clean dirty fans and replace the broken fans in a timely manner.
The operation procedure is as follows:
step 1 Stop the inverter (see
8.1 Disconnecting the Inverter
step 2 Loosen the screw on the sealing plate of the fan module.
step 3 Press the tab of the latch hook, unplug the cable connection joint outwards, and loosen the
screw on the fan holder.