Before any operation in the area that may be affected by an arc flash,
personal protective equipment (PPE) that meets the requirement must
be worn. A PPE category 2 is recommended.
Maintenance and Service
There is a risk of inverter damage or personal injury due to incorrect
service work!
Before any operation, you should perform the following steps:
First, disconnect the grid side switch and then disconnect the DC
switch;
Wait at least 10 minutes until the inner capacitors are discharged
completely;
Verify, using proper testing device to make sure there is no voltage or
current.
Keep unqualified persons away!
A temporary warning sign and barrier must be posted to keep
unqualified
persons
away
during
electrical
connection
and
maintenance.
Restart the inverter only when the fault that may impair the inverter
safety functions is removed.
Inverter contains no owner serviceable parts inside. Please contact
local authorized personnel if any service work is required.
Do not replace the inverter internal components without permission.
Damage to the inverter may occur and it may void any or all warranty
rights from SUNGROW.
There is a risk of inverter damage due to electrostatic discharge!