User Manual
14
Protection Function
−
AC short circuit protection
−
Ground insulation resistance monitoring
−
Grid voltage monitoring
−
Grid frequency monitoring
−
Residual current protection
−
DC injection of AC output current monitoring
−
Internal temperature monitoring
−
Anti-islanding protection
−
DC over-voltage protection
−
Over-current protection
−
Power module over-temperature protection
−
Anti-PID function (Optional)
−
PID recovery function (Optional)
−
Night SVG function (Optional)
1.3.3 Derating
Output derating is a way to protect the inverter from overload or potential faults.
Situations requiring inverter power derating are:
Ambient temperature is too high
Gird voltage is too low
Fluctuations of external power level
Input voltage is too high
Grid frequency* is too high
Note: *The over-frequency curve may vary with the country setting.
When temperature derating, high voltage derating, and grid voltage derating
conflict, the minimum of the three is taken as the power derating point.
Power Limit Setting
Inverter output power can be adjusted via the APP interface or remote grid
dispatch from the grid company.
In the integrated system, power control can also be performed via the EMS200
Over-temperature Derating
High ambient temperature, a broken fan or poor ventilation will lead to inverter