44
SUNFAR E300 SERIES
(
6
)
State feedback
Slave sends back slave basic running state to master, which exists in all type data frame.
(
Slave
feedback 4th and 5th
)
shown as below:
Data
Operation
Data
Operation
00H
Slave DC volt does not prepare well
10H
Reserved
01H
Slave FWD running
11H
FWD acc
02H
Slave REV running
12H
REV acc
03H
Slave stop
13H
Abrupt stop then startup
04H
Slave FWD jog running
14H
FWD dec
05H
Slave REV jog running
15H
REV dec
Slave is during DC
braking state
06H Reserved
16H
20H
Slave is during failure state
21H
Slave urgent stop
(
7
)
Check sum
ASC code value (ASC code format) / hex data sum from slave address to set data/ running
Ⅱ
Ⅱ
data.
(
8
)
Tail
Hex “0DH”, that’s ASC code of “CR”
Ⅱ
ASC
Ⅱ
When slave failure and state feedback data is
“
20H
”
, feedback data frame
7th and 8th data
(
data addr.
)
as failure code.
1.3 Frame Format Description
When master sends header, tail or check sum of data frame abnormal,
slave maybe can not be normal correspond.
E300 Series Mini-type Integrated Universal Inverter Manual