14
SUNFAR E300 SERIES
4.3 State Monitor Parameter List
Monitor code
Content
Unit
d-0
Inverter current output freq
Hz
d-1
Inverter current output current
(
virtual value
)
A
d-2
Inverter current output volt
(
virtual value
)
V
d-3
Motor rotate speed
rpm
d-4
Inverter inner DC volt
V
d-5
Inverter input AC volt
(
virtual value
)
V
d-6 Set
freq
Hz
d-7 Analog
input
AI
V
d-8
Running linear speed
d-9 Set
linear
speed
d-10 Input
terminal
state
d-11 Module
temperature
ºC
d-12 Analog
output
AO
V
d-13 Reserved
d-14
1st failure record
d-15
2nd failure record
d-16
3rd failure record
d-17
4th failure record
d-18
Output freq of last failure
Hz
d-19
Output current of last failure
A
d-20
Output volt of last failure
V
d-21
DC volt of last failure
V
4.4 Inverter Simple Operation
4.4.1 Inverter initialization set
(
1
)
Freq input channel selection
(
[F0.0]
)
Inverter initialization set is different based on each model. Set this parameter as 0, inverter
freq is set by panel number.
(
2
)
Operation input channel selection
(
[F0.2]
)
Inverter initialization set is different based on each model. Set this parameter as [F0.2] =###0,
inverter stop and startup is controlled by the key of operation panel
STOP
RUN
E300 Series Mini-type Integrated Universal Inverter Manual