![Sunfar E300 Series Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/sunfar/e300-series/e300-series_manual_1396022050.webp)
SUNFAR E300 SERIES 43
(
5
)
Slave correspond
Slave data correspond to master is for action feedback of master order frame. It exists in all type
data frame shown as below:
Data
Definition
Data
Definition
0
Slave receives data for normal
operation
1
Receive data beyond range
2
Slave running prohibit modifying
data
3
Data modification prohibited by
password
4
Try to read, reserve or hide
parameter
5 Reserved
6
Appointed parameter code or
invalid address
(
beyond
limitation
)
7
When adopt ASC code
Ⅱ
transmission data, it exists invalid
ASC code character
Ⅱ
8
Invalid order type or operation
order
9
~
F
Reserved
When slave corresponding byte data is “6
~
8”, frame length of
corresponding frame is 11 byte.
Frame format is shown as below:
0 1
2
3
4
5 6 7 8 9 10
Slave
cor
respond
Slave addr
.
Slave addr
.
Slave
cor
respond
0 0
Check su
m
Check su
m
Check su
m
Check su
m
Ta
il
Definition
Header
Slave addr.
Order/ corresponding area
Check area
0DH