Sundray Wireless AP-S800 Installation Guide
16 / 20
ü
Cables should not be placed near high-voltage pipe, fire pipe or lightning protection cable to
avoid electromagnetic interference.
ü
It is recommended to use PVC pipe, iron pipe, Plica pipe, or cable trunking to run cables. If a
metal pipe is used, the two ends of the pipe should be grounded.
ü
For outdoors PVC pipe placed horizontally, drill a small hole on the pipe so that the water
can drain out.
ü
For the holes in the wall, through which cables go, they should be blocked with waterproof
and fireproof materials.
3.6.1 Connecting RF Cable
Follow the following steps to connect RF cables to RF interfaces(2.4GHz and 5GHz):
(1)
Install a feeder lightning arrester onto each RF interface, as shown below:
Figure3-8 Installation of Feeder Lightning Arrester on RF Interface