Description of all Functions
Diagram or steps in the spray-arm distributor motor’s behaviour.
Distributor closed Distributor open Distrib. motor active (change of state)
Spray arm distributor motor not active
Distributor
fi
xed positions
Alternating spray arm motor active.
Change of state zone.
Upper D. 50sec
Upper D. 50sec
Upper D. 50sec
Upper D. 50sec
Lower D.1/2 10sec
Lower D.1/2 10sec
Lower D. 50sec
Lower D. 50sec
Upper D. 10sec
Upper D. 10sec
Lower D. 10sec
Lower D. 10sec
Lower D.50 sec
Lower D.50 sec
Upper D.1/2 10sec
Upper D.1/2 10sec
The error code is detected during the wash cycle in which the wash motor is active.
If at any moment in the program when the electronic module activates the spray-arm
distributor motor, to change its position state, no change of state is detected, then this
will be indicated by error code F9.
The change of state will be determined by a change in the distributor position which
will be detected by the cam which in turn is detected by the electrical contact, which
is what informs the electronic module of the change.
If there is a fault related to this error code, the machine will stop, and beep as
follows:
9 beeps
pause 4” 9 beeps
pause 4”……… and so on.